Last modified by Xiaoling on 2023/07/18 10:12

From version 242.1
edited by Ellie Zhang
on 2023/05/08 11:29
Change comment: There is no comment for this version
To version 247.1
edited by Ellie Zhang
on 2023/05/09 14:09
Change comment: Uploaded new attachment "SHT31.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -1033,20 +1033,45 @@
1033 1033  * Operating Range: -40 ~~ 125 °C
1034 1034  * Working voltage 2.35v ~~ 5v
1035 1035  
1036 +
1036 1036  == 3.3 E31F Temperature Probe ==
1037 1037  
1038 1038  
1039 -[[image:65N-E31F-1.jpg||height="161" width="162"]] [[image:65N-E31F.jpg||height="192" width="194"]]
1040 +[[image:65N-E31F-1.jpg||height="169" width="170"]] [[image:65N-E31F.jpg||height="196" width="198"]]
1040 1040  
1041 1041  
1042 1042  Temperature sensor with 1 meters cable long
1043 1043  
1045 +**Built-in Temperature Sensor:**
1046 +
1044 1044  * Resolution: 0.01 °C
1048 +* Accuracy Tolerance : Typ ±0.3 °C
1049 +* Long Term Drift: < 0.02 °C/yr
1050 +* Operating Range: -40 ~~ 80 °C
1051 +
1052 +**Built-in Humidity Sensor:**
1053 +
1054 +* Resolution: 0.04 %RH
1055 +* Accuracy Tolerance : Typ ±3 %RH
1056 +* Long Term Drift: < 0.02 °C/yr
1057 +* Operating Range: 0 ~~ 96 %RH
1058 +
1059 +
1060 +**External Temperature Sensor :**
1061 +
1062 +* Resolution: 0.01 °C
1045 1045  * Accuracy Tolerance : Typical ±0.3 °C
1046 1046  * Long Term Drift: < 0.02 °C/yr
1047 1047  * Operating Range: -40 ~~ 125 °C
1048 -* Working voltage 2.35v ~~ 5v
1049 1049  
1067 +**External Humidity Sensor :**
1068 +
1069 +* Resolution: 0.04 %RH
1070 +* Accuracy Tolerance : Typ ±3 %RH
1071 +* Long Term Drift: < 0.02 °C/yr
1072 +* Operating Range: 0 ~~ 96 %RH
1073 +
1074 +
1050 1050  = 4. Configure LHT65N via AT command or LoRaWAN downlink =
1051 1051  
1052 1052  
SHT31.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ellie
Size
... ... @@ -1,0 +1,1 @@
1 +7.6 KB
Content
image-20230509140803-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ellie
Size
... ... @@ -1,0 +1,1 @@
1 +11.1 KB
Content