Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 234.3
edited by Xiaoling
on 2023/04/26 14:37
on 2023/04/26 14:37
Change comment:
There is no comment for this version
To version 228.1
edited by Bei Jinggeng
on 2023/02/01 11:15
on 2023/02/01 11:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -46,6 +46,7 @@ 46 46 == 1.2 Features == 47 47 48 48 49 +* Wall mountable 49 49 * LoRaWAN v1.0.3 Class A protocol 50 50 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 51 51 * AT Commands to change parameters ... ... @@ -116,19 +116,9 @@ 116 116 117 117 [[image:image-20220515123819-1.png||_mstalt="430742" height="379" width="317"]] 118 118 119 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 120 -|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 121 -|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)((( 122 -If LHT65N is already Joined to rhe LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once. 123 -))) 124 -|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 125 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. 126 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after join in network. 127 -))) 128 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 120 +[[image:image-20220525110604-2.png||_mstalt="427531"]] 129 129 130 130 131 - 132 132 == 2.3 Example to join LoRaWAN network == 133 133 134 134 ... ... @@ -156,7 +156,7 @@ 156 156 Each LHT65N is shipped with a sticker with its device EUI, APP Key and APP EUI as below: 157 157 ))) 158 158 159 -[[image:image-202 30426083319-1.png]]150 +[[image:image-20220617150003-1.jpeg||_mstalt="5426434"]] 160 160 161 161 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: 162 162 ... ... @@ -260,7 +260,6 @@ 260 260 261 261 [[image:image-20220523152839-18.png||_mstalt="457613"]] 262 262 263 -(b)stands for binary 264 264 265 265 [[image:image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 266 266 ... ... @@ -267,8 +267,8 @@ 267 267 268 268 Check the battery voltage for LHT65N. 269 269 270 -* BAT status=(0Xcba4>>14)&0xFF=11 IN)271 -* Battery Voltage =0xCB A4&0x3FFF=0x0BA4=2980mV260 +* BAT status=(0Xcba4>>14)&0xFF=11(B),very good 261 +* Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 272 272 273 273 === 2.4.3 Built-in Temperature === 274 274 ... ... @@ -324,7 +324,6 @@ 324 324 If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃ 325 325 326 326 327 - 328 328 ==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ==== 329 329 330 330 ... ... @@ -436,7 +436,6 @@ 436 436 [[image:image-20220628151143-7.png||_mstalt="431210"]] 437 437 438 438 439 - 440 440 ==== 2.4.6.4 Ext~=2 TMP117 Sensor (Since Firmware v1.3) ==== 441 441 442 442 ... ... @@ -453,7 +453,6 @@ 453 453 The external cable NE2 can be use for MOD4 and MOD8 454 454 455 455 456 - 457 457 ==== 2.4.6.5 Ext~=4 Interrupt Mode (Since Firmware v1.3) ==== 458 458 459 459 ... ... @@ -500,7 +500,6 @@ 500 500 [[image:image-20220906101145-3.png||_mstalt="428688"]] 501 501 502 502 503 - 504 504 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 505 505 506 506 ... ... @@ -866,18 +866,17 @@ 866 866 temperature fluctuation=05 867 867 868 868 869 -**Sampling multiple times and uplink together** 855 +==== **Sampling multiple times and uplink together** ==== 870 870 871 871 **AT+WMOD=3,1,60,20,-16,32,1** 872 872 873 873 Explain: 874 874 875 -* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3** 876 -* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 877 -* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s. 878 -* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 879 -* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C, 880 -* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 861 +* Set Working Mode to **Mode 3** 862 +* Sampling Interval is **60**s. 863 +* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 864 +* Temperature alarm range is **-16** to **32**°C, 865 +* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 881 881 882 882 (% style="color:#4f81bd" %)**Downlink Command:** 883 883 ... ... @@ -885,7 +885,7 @@ 885 885 886 886 MOD=03 887 887 888 - TEMP=DS18B20873 +EXT=01 889 889 890 890 CITEMP=003C(S) 891 891 ... ... @@ -897,6 +897,7 @@ 897 897 898 898 ARTEMP=01 899 899 885 + 900 900 **Uplink payload( Fport=3)** 901 901 902 902 **Example: CBEA**01**0992**//0A41//**09C4** ... ... @@ -903,7 +903,7 @@ 903 903 904 904 BatV=CBEA 905 905 906 - TEMP=DS18B20892 +EXT=01 907 907 908 908 Temp1=0992 ~/~/ 24.50℃ 909 909 ... ... @@ -911,9 +911,10 @@ 911 911 912 912 Temp3=09C4 ~/~/ 25.00℃ 913 913 900 + 914 914 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 915 915 916 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ 903 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 917 917 ))) 918 918 919 919 ... ... @@ -1633,7 +1633,7 @@ 1633 1633 [[image:image-20220615153355-1.png||_mstalt="430222"]] 1634 1634 1635 1635 1636 -(% style="color:blue" %)**Step1**(%%): Install [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]]first.1623 +(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 1637 1637 1638 1638 [[image:image-20220615170542-5.png||_mstalt="430638"]] 1639 1639 ... ... @@ -1699,7 +1699,7 @@ 1699 1699 [[image:image-20220623110706-1.png||_mstalt="427869"]] 1700 1700 1701 1701 1702 -(% style="color:blue" %)**Step1**(%%): Install [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]]first.1689 +(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 1703 1703 1704 1704 [[image:image-20220615170542-5.png||_mstalt="430638"]] 1705 1705 ... ... @@ -1785,3 +1785,6 @@ 1785 1785 (1) This device may not cause harmful interference; 1786 1786 1787 1787 (2) this device must accept any interference received, including interference that may cause undesired operation. 1775 + 1776 + 1777 +
- image-20230426083319-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -190.0 KB - Content