Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -127,6 +127,8 @@ 127 127 ))) 128 128 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 129 129 130 + 131 + 130 130 == 2.3 Example to join LoRaWAN network == 131 131 132 132 ... ... @@ -256,25 +256,12 @@ 256 256 === 2.4.2 BAT-Battery Info === 257 257 258 258 259 -These two bytes of BAT include the battery state and the actually voltage .261 +These two bytes of BAT include the battery state and the actually voltage 260 260 261 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:477px" %) 262 -|=(% style="width: 69px; background-color:#D9E2F3;color:#0070C0" %)((( 263 -**Bit(bit)** 264 -)))|=(% style="width: 253px;background-color:#D9E2F3;color:#0070C0" %)[15:14]|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)[13:0] 265 -|(% style="width:66px" %)((( 266 -**Value** 267 -)))|(% style="width:250px" %)((( 268 -BAT Status 269 -00(b): Ultra Low ( BAT <= 2.50v) 270 -01(b): Low (2.50v <=BAT <= 2.55v) 271 -10(b): OK (2.55v <= BAT <=2.65v) 272 -11(b): Good (BAT >= 2.65v) 273 -)))|(% style="width:152px" %)Actually BAT voltage 263 +[[image:image-20220523152839-18.png||_mstalt="457613"]] 274 274 275 - **(b)stands for binary**265 +(b)stands for binary 276 276 277 - 278 278 [[image:image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 279 279 280 280 ... ... @@ -281,7 +281,6 @@ 281 281 Check the battery voltage for LHT65N. 282 282 283 283 * BAT status=(0Xcba4>>14)&0xFF=11 (BIN) ,very good 284 - 285 285 * Battery Voltage =0xCBA4&0x3FFF=0x0BA4=2980mV 286 286 287 287 === 2.4.3 Built-in Temperature === ... ... @@ -307,10 +307,7 @@ 307 307 308 308 Bytes for External Sensor: 309 309 310 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:425px" %) 311 -|=(% style="width: 102px; background-color:#D9E2F3;color:#0070C0" %)**EXT # Value**|=(% style="width: 323px;background-color:#D9E2F3;color:#0070C0" %)**External Sensor Type** 312 -|(% style="width:102px" %)0x01|(% style="width:319px" %)Sensor E3, Temperature Sensor 313 -|(% style="width:102px" %)0x09|(% style="width:319px" %)Sensor E3, Temperature Sensor, Datalog Mod 298 +[[image:image-20220523152822-17.png||_mstalt="454545"]] 314 314 315 315 316 316 === 2.4.6 Ext value === ... ... @@ -349,19 +349,22 @@ 349 349 Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below: 350 350 ))) 351 351 337 +((( 338 + 339 +))) 352 352 353 -(% border="1" cellspacing="4" style="background-color:#f 2f2f2; width:480px" %)354 -|=(% style="width: 50px; background-color:#D9E2F3" %)(((341 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:480px" %) 342 +|=(% style="width: 50px;" %)((( 355 355 **Size(bytes)** 356 -)))|=(% style="width: 70px; background-color:#D9E2F3" %)(((344 +)))|=(% style="width: 70px;" %)((( 357 357 **2** 358 -)))|=(% style="width: 120px; background-color:#D9E2F3" %)(((346 +)))|=(% style="width: 120px;" %)((( 359 359 **2** 360 -)))|=(% style="width: 120px; background-color:#D9E2F3" %)(((348 +)))|=(% style="width: 120px;" %)((( 361 361 **2** 362 -)))|=(% style="width: 50px; background-color:#D9E2F3" %)(((350 +)))|=(% style="width: 50px;" %)((( 363 363 **1** 364 -)))|=(% style="width: 70px; background-color:#D9E2F3" %)(((352 +)))|=(% style="width: 70px;" %)((( 365 365 **4** 366 366 ))) 367 367 |(% style="width:110px" %)((( ... ... @@ -380,8 +380,8 @@ 380 380 381 381 * **Battery status & Built-in Humidity** 382 382 383 -(% border="1" cellspacing="4" style="background-color:#f 2f2f2; width:461px" %)384 -|=(% style="width: 6 9px;background-color:#D9E2F3;color:#0070C0" %)Bit(bit)|=(% style="width: 258px;background-color:#D9E2F3;color:#0070C0" %)[15:14]|=(% style="width: 134px;background-color:#D9E2F3;color:#0070C0" %)[11:0]371 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:461px" %) 372 +|=(% style="width: 67px;" %)Bit(bit)|=(% style="width: 256px;" %)[15:14]|=(% style="width: 132px;" %)[11:0] 385 385 |(% style="width:67px" %)Value|(% style="width:256px" %)((( 386 386 BAT Status 387 387 00(b): Ultra Low ( BAT <= 2.50v) ... ... @@ -394,8 +394,8 @@ 394 394 395 395 * **Status & Ext Byte** 396 396 397 -(% border="1" cellspacing="4" style="background-color:#f 2f2f2; width:500px" %)398 -|=(% style="width: 60px; background-color:#D9E2F3;color:#0070C0" %)**Bits**|(% style="width:90px;background-color:#D9E2F3;color:#0070C0" %)**7**|(% style="width:100px;background-color:#D9E2F3;color:#0070C0" %)**6**|(% style="width:90px;background-color:#D9E2F3;color:#0070C0" %)**5**|(% style="width:100px;background-color:#D9E2F3;color:#0070C0" %)**4**|(% style="width:60px;background-color:#D9E2F3;color:#0070C0" %)**[3:0]**385 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:500px" %) 386 +|=(% scope="row" style="width: 60px;" %)**Bits**|(% style="width:90px" %)**7**|(% style="width:100px" %)**6**|(% style="width:90px" %)**5**|(% style="width:100px" %)**4**|(% style="width:60px" %)**[3:0]** 399 399 |=(% style="width: 96px;" %)**Status&Ext**|(% style="width:124px" %)None-ACK Flag|(% style="width:146px" %)Poll Message FLAG|(% style="width:109px" %)Sync time OK|(% style="width:143px" %)Unix Time Request|(% style="width:106px" %)Ext: 0b(1001) 400 400 401 401 * (% style="color:blue" %)**Poll Message Flag**:(%%) 1: This message is a poll message reply, 0: means this is a normal uplink.