Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 234.11
edited by Xiaoling
on 2023/04/26 14:57
on 2023/04/26 14:57
Change comment:
There is no comment for this version
To version 228.1
edited by Bei Jinggeng
on 2023/02/01 11:15
on 2023/02/01 11:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -46,6 +46,7 @@ 46 46 == 1.2 Features == 47 47 48 48 49 +* Wall mountable 49 49 * LoRaWAN v1.0.3 Class A protocol 50 50 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 51 51 * AT Commands to change parameters ... ... @@ -116,17 +116,9 @@ 116 116 117 117 [[image:image-20220515123819-1.png||_mstalt="430742" height="379" width="317"]] 118 118 119 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 120 -|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 121 -|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)((( 122 -If LHT65N is already Joined to rhe LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once. 123 -))) 124 -|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 125 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. 126 -(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after join in network. 127 -))) 128 -|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 120 +[[image:image-20220525110604-2.png||_mstalt="427531"]] 129 129 122 + 130 130 == 2.3 Example to join LoRaWAN network == 131 131 132 132 ... ... @@ -154,7 +154,7 @@ 154 154 Each LHT65N is shipped with a sticker with its device EUI, APP Key and APP EUI as below: 155 155 ))) 156 156 157 -[[image:image-202 30426083319-1.png]]150 +[[image:image-20220617150003-1.jpeg||_mstalt="5426434"]] 158 158 159 159 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: 160 160 ... ... @@ -204,18 +204,18 @@ 204 204 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. 205 205 ))) 206 206 207 -(% border="1" cellspacing="4" style="background-color:#f 2f2f2; width:390px" %)208 -|=(% style="width: 60px; background-color:#D9E2F3" %)(((200 +(% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:390px" %) 201 +|=(% style="width: 60px;" %)((( 209 209 **Size(bytes)** 210 -)))|=(% style="width: 30px; background-color:#D9E2F3" %)(((203 +)))|=(% style="width: 30px;" %)((( 211 211 **2** 212 -)))|=(% style="width: 100px; background-color:#D9E2F3" %)(((205 +)))|=(% style="width: 100px;" %)((( 213 213 **2** 214 -)))|=(% style="width: 100px; background-color:#D9E2F3" %)(((207 +)))|=(% style="width: 100px;" %)((( 215 215 **2** 216 -)))|=(% style="width: 50px; background-color:#D9E2F3" %)(((209 +)))|=(% style="width: 50px;" %)((( 217 217 **1** 218 -)))|=(% style="width: 50px; background-color:#D9E2F3" %)(((211 +)))|=(% style="width: 50px;" %)((( 219 219 **4** 220 220 ))) 221 221 |(% style="width:97px" %)((( ... ... @@ -237,9 +237,7 @@ 237 237 ))) 238 238 239 239 * The First 6 bytes: has fix meanings for every LHT65N. 240 - 241 241 * The 7th byte (EXT #): defines the external sensor model. 242 - 243 243 * The 8^^th^^ ~~ 11^^th^^ byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 244 244 245 245 === 2.4.1 Decoder in TTN V3 === ... ... @@ -256,37 +256,18 @@ 256 256 === 2.4.2 BAT-Battery Info === 257 257 258 258 259 -These two bytes of BAT include the battery state and the actually voltage .250 +These two bytes of BAT include the battery state and the actually voltage 260 260 261 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:485px" %) 262 -|=(% style="width: 72px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 263 -**Bit(bit)** 264 -)))|=(% style="width: 252px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)[15:14]|=(% style="width: 153px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)[13:0] 265 -|(% style="width:72px" %)((( 266 -**Value** 267 -)))|(% style="width:252px" %)((( 268 -BAT Status 252 +[[image:image-20220523152839-18.png||_mstalt="457613"]] 269 269 270 -00(b): Ultra Low ( BAT <= 2.50v) 271 271 272 -01(b): Low (2.50v <=BAT <= 2.55v) 273 - 274 -10(b): OK (2.55v <= BAT <=2.65v) 275 - 276 -11(b): Good (BAT >= 2.65v) 277 -)))|(% style="width:153px" %)Actually BAT voltage 278 - 279 - 280 -**(b)stands for binary** 281 - 282 - 283 283 [[image:image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 284 284 285 285 286 286 Check the battery voltage for LHT65N. 287 287 288 -* BAT status=(0Xcba4>>14)&0xFF=11 IN)289 -* Battery Voltage =0xCB A4&0x3FFF=0x0BA4=2980mV260 +* BAT status=(0Xcba4>>14)&0xFF=11(B),very good 261 +* Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 290 290 291 291 === 2.4.3 Built-in Temperature === 292 292 ... ... @@ -342,7 +342,6 @@ 342 342 If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃ 343 343 344 344 345 - 346 346 ==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ==== 347 347 348 348 ... ... @@ -454,7 +454,6 @@ 454 454 [[image:image-20220628151143-7.png||_mstalt="431210"]] 455 455 456 456 457 - 458 458 ==== 2.4.6.4 Ext~=2 TMP117 Sensor (Since Firmware v1.3) ==== 459 459 460 460 ... ... @@ -471,7 +471,6 @@ 471 471 The external cable NE2 can be use for MOD4 and MOD8 472 472 473 473 474 - 475 475 ==== 2.4.6.5 Ext~=4 Interrupt Mode (Since Firmware v1.3) ==== 476 476 477 477 ... ... @@ -518,7 +518,6 @@ 518 518 [[image:image-20220906101145-3.png||_mstalt="428688"]] 519 519 520 520 521 - 522 522 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 523 523 524 524 ... ... @@ -884,18 +884,17 @@ 884 884 temperature fluctuation=05 885 885 886 886 887 -**Sampling multiple times and uplink together** 855 +==== **Sampling multiple times and uplink together** ==== 888 888 889 889 **AT+WMOD=3,1,60,20,-16,32,1** 890 890 891 891 Explain: 892 892 893 -* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3** 894 -* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 895 -* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s. 896 -* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 897 -* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C, 898 -* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 861 +* Set Working Mode to **Mode 3** 862 +* Sampling Interval is **60**s. 863 +* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 864 +* Temperature alarm range is **-16** to **32**°C, 865 +* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 899 899 900 900 (% style="color:#4f81bd" %)**Downlink Command:** 901 901 ... ... @@ -903,7 +903,7 @@ 903 903 904 904 MOD=03 905 905 906 - TEMP=DS18B20873 +EXT=01 907 907 908 908 CITEMP=003C(S) 909 909 ... ... @@ -915,6 +915,7 @@ 915 915 916 916 ARTEMP=01 917 917 885 + 918 918 **Uplink payload( Fport=3)** 919 919 920 920 **Example: CBEA**01**0992**//0A41//**09C4** ... ... @@ -921,7 +921,7 @@ 921 921 922 922 BatV=CBEA 923 923 924 - TEMP=DS18B20892 +EXT=01 925 925 926 926 Temp1=0992 ~/~/ 24.50℃ 927 927 ... ... @@ -929,9 +929,10 @@ 929 929 930 930 Temp3=09C4 ~/~/ 25.00℃ 931 931 900 + 932 932 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 933 933 934 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ 903 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 935 935 ))) 936 936 937 937 ... ... @@ -1651,7 +1651,7 @@ 1651 1651 [[image:image-20220615153355-1.png||_mstalt="430222"]] 1652 1652 1653 1653 1654 -(% style="color:blue" %)**Step1**(%%): Install [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]]first.1623 +(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 1655 1655 1656 1656 [[image:image-20220615170542-5.png||_mstalt="430638"]] 1657 1657 ... ... @@ -1717,7 +1717,7 @@ 1717 1717 [[image:image-20220623110706-1.png||_mstalt="427869"]] 1718 1718 1719 1719 1720 -(% style="color:blue" %)**Step1**(%%): Install [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]]first.1689 +(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 1721 1721 1722 1722 [[image:image-20220615170542-5.png||_mstalt="430638"]] 1723 1723 ... ... @@ -1803,3 +1803,6 @@ 1803 1803 (1) This device may not cause harmful interference; 1804 1804 1805 1805 (2) this device must accept any interference received, including interference that may cause undesired operation. 1775 + 1776 + 1777 +
- image-20230426083319-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -190.0 KB - Content