Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -256,7 +256,6 @@ 256 256 257 257 [[image:image-20220523152839-18.png||_mstalt="457613"]] 258 258 259 -(b)stands for binary 260 260 261 261 [[image:image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 262 262 ... ... @@ -263,8 +263,8 @@ 263 263 264 264 Check the battery voltage for LHT65N. 265 265 266 -* BAT status=(0Xcba4>>14)&0xFF=11 IN)267 -* Battery Voltage =0xCB A4&0x3FFF=0x0BA4=2980mV265 +* BAT status=(0Xcba4>>14)&0xFF=11(B),very good 266 +* Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 268 268 269 269 270 270 ... ... @@ -870,18 +870,18 @@ 870 870 temperature fluctuation=05 871 871 872 872 873 -**Sampling multiple times and uplink together** 872 +==== **Sampling multiple times and uplink together** ==== 874 874 874 + 875 875 **AT+WMOD=3,1,60,20,-16,32,1** 876 876 877 877 Explain: 878 878 879 -* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3** 880 -* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 881 -* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s. 882 -* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 883 -* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C, 884 -* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 879 +* Set Working Mode to **Mode 3** 880 +* Sampling Interval is **60**s. 881 +* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 882 +* Temperature alarm range is **-16** to **32**°C, 883 +* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 885 885 886 886 (% style="color:#4f81bd" %)**Downlink Command:** 887 887 ... ... @@ -889,7 +889,7 @@ 889 889 890 890 MOD=03 891 891 892 - TEMP=DS18B20891 +EXT=01 893 893 894 894 CITEMP=003C(S) 895 895 ... ... @@ -901,6 +901,7 @@ 901 901 902 902 ARTEMP=01 903 903 903 + 904 904 **Uplink payload( Fport=3)** 905 905 906 906 **Example: CBEA**01**0992**//0A41//**09C4** ... ... @@ -907,7 +907,7 @@ 907 907 908 908 BatV=CBEA 909 909 910 - TEMP=DS18B20910 +EXT=01 911 911 912 912 Temp1=0992 ~/~/ 24.50℃ 913 913 ... ... @@ -915,9 +915,10 @@ 915 915 916 916 Temp3=09C4 ~/~/ 25.00℃ 917 917 918 + 918 918 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 919 919 920 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ 921 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 921 921 ))) 922 922 923 923