... ... @@ -46,6 +46,7 @@
46 46  == 1.2 Features ==
47 47  
48 48  
49 +* Wall mountable
49 49  * LoRaWAN v1.0.3 Class A protocol
50 50  * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915
51 51  * AT Commands to change parameters
... ... @@ -869,18 +869,18 @@
869 869  temperature fluctuation=05
870 870  
871 871  
872 -**Sampling multiple times and uplink together**
873 +==== **Sampling multiple times and uplink together** ====
873 873  
875 +
874 874  **AT+WMOD=3,1,60,20,-16,32,1**   
875 875  
876 876  Explain:
877 877  
878 -* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3**
879 -* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30).
880 -* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s.
881 -* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink)
882 -* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C,
883 -* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately  if temperate exceeds the Alarm range.
880 +* Set Working Mode to **Mode 3**
881 +* Sampling Interval is **60**s.
882 +* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink)
883 +* Temperature alarm range is **-16** to **32**°C,
884 +* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately  if temperate exceeds the Alarm range.
884 884  
885 885  (% style="color:#4f81bd" %)**Downlink Command:**
886 886  
... ... @@ -888,7 +888,7 @@
888 888  
889 889  MOD=03
890 890  
891 -TEMP=DS18B20
892 +EXT=01
892 892  
893 893  CITEMP=003C(S)
894 894  
... ... @@ -900,6 +900,7 @@
900 900  
901 901  ARTEMP=01
902 902  
904 +
903 903  **Uplink payload( Fport=3)**
904 904  
905 905  **Example: CBEA**01**0992**//0A41//**09C4**
... ... @@ -906,7 +906,7 @@
906 906  
907 907  BatV=CBEA
908 908  
909 -TEMP=DS18B20
911 +EXT=01
910 910  
911 911  Temp1=0992  ~/~/ 24.50℃
912 912  
... ... @@ -914,9 +914,10 @@
914 914  
915 915  Temp3=09C4  ~/~/ 25.00℃
916 916  
919 +
917 917  (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length**
918 918  
919 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption**
922 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption**
920 920  )))
921 921  