Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 229.2
edited by Xiaoling
on 2023/03/03 10:45
on 2023/03/03 10:45
Change comment:
There is no comment for this version
To version 228.1
edited by Bei Jinggeng
on 2023/02/01 11:15
on 2023/02/01 11:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -46,6 +46,7 @@ 46 46 == 1.2 Features == 47 47 48 48 49 +* Wall mountable 49 49 * LoRaWAN v1.0.3 Class A protocol 50 50 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 51 51 * AT Commands to change parameters ... ... @@ -57,8 +57,6 @@ 57 57 * Tri-color LED to indicate working status 58 58 * Datalog feature (Max 3328 records) 59 59 60 - 61 - 62 62 == 1.3 Specification == 63 63 64 64 ... ... @@ -83,8 +83,6 @@ 83 83 * ±2°C accuracy from -55°C to +125°C 84 84 * Operating Range: -55 °C ~~ 125 °C 85 85 86 - 87 - 88 88 = 2. Connect LHT65N to IoT Server = 89 89 90 90 == 2.1 How does LHT65N work? == ... ... @@ -236,8 +236,6 @@ 236 236 * The 7th byte (EXT #): defines the external sensor model. 237 237 * The 8^^th^^ ~~ 11^^th^^ byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 238 238 239 - 240 - 241 241 === 2.4.1 Decoder in TTN V3 === 242 242 243 243 ... ... @@ -265,8 +265,6 @@ 265 265 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 266 266 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 267 267 268 - 269 - 270 270 === 2.4.3 Built-in Temperature === 271 271 272 272 ... ... @@ -278,8 +278,6 @@ 278 278 279 279 * Temperature: (0xF5C6-65536)/100=-26.18℃ 280 280 281 - 282 - 283 283 === 2.4.4 Built-in Humidity === 284 284 285 285 ... ... @@ -287,8 +287,6 @@ 287 287 288 288 * Humidity: 0x025C/10=60.4% 289 289 290 - 291 - 292 292 === 2.4.5 Ext # === 293 293 294 294 ... ... @@ -325,7 +325,6 @@ 325 325 If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃ 326 326 327 327 328 - 329 329 ==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ==== 330 330 331 331 ... ... @@ -389,8 +389,6 @@ 389 389 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 390 390 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 391 391 392 - 393 - 394 394 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 395 395 396 396 ... ... @@ -439,7 +439,6 @@ 439 439 [[image:image-20220628151143-7.png||_mstalt="431210"]] 440 440 441 441 442 - 443 443 ==== 2.4.6.4 Ext~=2 TMP117 Sensor (Since Firmware v1.3) ==== 444 444 445 445 ... ... @@ -456,7 +456,6 @@ 456 456 The external cable NE2 can be use for MOD4 and MOD8 457 457 458 458 459 - 460 460 ==== 2.4.6.5 Ext~=4 Interrupt Mode (Since Firmware v1.3) ==== 461 461 462 462 ... ... @@ -503,7 +503,6 @@ 503 503 [[image:image-20220906101145-3.png||_mstalt="428688"]] 504 504 505 505 506 - 507 507 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 508 508 509 509 ... ... @@ -869,18 +869,17 @@ 869 869 temperature fluctuation=05 870 870 871 871 872 -**Sampling multiple times and uplink together** 855 +==== **Sampling multiple times and uplink together** ==== 873 873 874 874 **AT+WMOD=3,1,60,20,-16,32,1** 875 875 876 876 Explain: 877 877 878 -* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3** 879 -* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 880 -* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s. 881 -* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 882 -* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C, 883 -* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 861 +* Set Working Mode to **Mode 3** 862 +* Sampling Interval is **60**s. 863 +* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 864 +* Temperature alarm range is **-16** to **32**°C, 865 +* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 884 884 885 885 (% style="color:#4f81bd" %)**Downlink Command:** 886 886 ... ... @@ -888,7 +888,7 @@ 888 888 889 889 MOD=03 890 890 891 - TEMP=DS18B20873 +EXT=01 892 892 893 893 CITEMP=003C(S) 894 894 ... ... @@ -900,6 +900,7 @@ 900 900 901 901 ARTEMP=01 902 902 885 + 903 903 **Uplink payload( Fport=3)** 904 904 905 905 **Example: CBEA**01**0992**//0A41//**09C4** ... ... @@ -906,7 +906,7 @@ 906 906 907 907 BatV=CBEA 908 908 909 - TEMP=DS18B20892 +EXT=01 910 910 911 911 Temp1=0992 ~/~/ 24.50℃ 912 912 ... ... @@ -914,9 +914,10 @@ 914 914 915 915 Temp3=09C4 ~/~/ 25.00℃ 916 916 900 + 917 917 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 918 918 919 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ 903 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 920 920 ))) 921 921 922 922 ... ... @@ -975,8 +975,6 @@ 975 975 * RED LED when external sensor is not connected 976 976 * For each success downlink, the PURPLE LED will blink once 977 977 978 - 979 - 980 980 == 2.9 installation == 981 981 982 982 ... ... @@ -1029,8 +1029,6 @@ 1029 1029 * Operating Range: -40 ~~ 125 °C 1030 1030 * Working voltage 2.35v ~~ 5v 1031 1031 1032 - 1033 - 1034 1034 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1035 1035 1036 1036 ... ... @@ -1099,8 +1099,6 @@ 1099 1099 1100 1100 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1101 1101 1102 - 1103 - 1104 1104 == 4.2 Set External Sensor Mode == 1105 1105 1106 1106 ... ... @@ -1124,8 +1124,6 @@ 1124 1124 1125 1125 * 0xA20702003c: Same as AT+SETCNT=60 1126 1126 1127 - 1128 - 1129 1129 == 4.3 Enable/Disable uplink Temperature probe ID == 1130 1130 1131 1131 ... ... @@ -1156,8 +1156,6 @@ 1156 1156 * **0xA800** **~-~->** AT+PID=0 1157 1157 * **0xA801** **~-~->** AT+PID=1 1158 1158 1159 - 1160 - 1161 1161 == 4.4 Set Password == 1162 1162 1163 1163 ... ... @@ -1207,8 +1207,6 @@ 1207 1207 1208 1208 * There is no downlink command to set to Sleep mode. 1209 1209 1210 - 1211 - 1212 1212 == 4.7 Set system time == 1213 1213 1214 1214 ... ... @@ -1312,8 +1312,6 @@ 1312 1312 1313 1313 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1314 1314 1315 - 1316 - 1317 1317 == 4.13 Auto Send None-ACK messages == 1318 1318 1319 1319 ... ... @@ -1332,8 +1332,6 @@ 1332 1332 1333 1333 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1334 1334 1335 - 1336 - 1337 1337 == 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1338 1338 1339 1339 ... ... @@ -1778,8 +1778,6 @@ 1778 1778 1779 1779 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1780 1780 1781 - 1782 - 1783 1783 = 8. Packing Info = 1784 1784 1785 1785 ... ... @@ -1793,15 +1793,11 @@ 1793 1793 * Device Size: 10 x 10 x 3.5 mm 1794 1794 * Device Weight: 120.5g 1795 1795 1796 - 1797 - 1798 1798 = 9. Reference material = 1799 1799 1800 1800 1801 1801 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 1802 1802 1803 - 1804 - 1805 1805 = 10. FCC Warning = 1806 1806 1807 1807