... ... @@ -256,6 +256,7 @@
256 256  
257 257  [[image:image-20220523152839-18.png||_mstalt="457613"]]
258 258  
259 +(b)stands for binary
259 259  
260 260  [[image:image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]]
261 261  
... ... @@ -262,8 +262,8 @@
262 262  
263 263  Check the battery voltage for LHT65N.
264 264  
265 -* BAT status=(0Xcba4>>14)&0xFF=11(B),very good
266 -* Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
266 +* BAT status=(0Xcba4>>14)&0xFF=11 (BIN) ,very good
267 +* Battery Voltage =0xCBA4&0x3FFF=0x0BA4=2980mV
267 267  
268 268  
269 269  
... ... @@ -869,18 +869,18 @@
869 869  temperature fluctuation=05
870 870  
871 871  
872 -==== **Sampling multiple times and uplink together** ====
873 +**Sampling multiple times and uplink together**
873 873  
874 -
875 875  **AT+WMOD=3,1,60,20,-16,32,1**   
876 876  
877 877  Explain:
878 878  
879 -* Set Working Mode to **Mode 3**
880 -* Sampling Interval is **60**s.
881 -* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink)
882 -* Temperature alarm range is **-16** to **32**°C,
883 -* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately  if temperate exceeds the Alarm range.
879 +* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3**
880 +* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30).
881 +* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s.
882 +* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink)
883 +* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C,
884 +* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately  if temperate exceeds the Alarm range.
884 884  
885 885  (% style="color:#4f81bd" %)**Downlink Command:**
886 886  
... ... @@ -888,7 +888,7 @@
888 888  
889 889  MOD=03
890 890  
891 -EXT=01
892 +TEMP=DS18B20
892 892  
893 893  CITEMP=003C(S)
894 894  
... ... @@ -900,7 +900,6 @@
900 900  
901 901  ARTEMP=01
902 902  
903 -
904 904  **Uplink payload( Fport=3)**
905 905  
906 906  **Example: CBEA**01**0992**//0A41//**09C4**
... ... @@ -907,7 +907,7 @@
907 907  
908 908  BatV=CBEA
909 909  
910 -EXT=01
910 +TEMP=DS18B20
911 911  
912 912  Temp1=0992  ~/~/ 24.50℃
913 913  
... ... @@ -915,10 +915,9 @@
915 915  
916 916  Temp3=09C4  ~/~/ 25.00℃
917 917  
918 -
919 919  (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length**
920 920  
921 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption**
920 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption**
922 922  )))