Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 228.1
edited by Bei Jinggeng
on 2023/02/01 11:15
on 2023/02/01 11:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -46,7 +46,6 @@ 46 46 == 1.2 Features == 47 47 48 48 49 -* Wall mountable 50 50 * LoRaWAN v1.0.3 Class A protocol 51 51 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 52 52 * AT Commands to change parameters ... ... @@ -117,9 +117,19 @@ 117 117 118 118 [[image:image-20220515123819-1.png||_mstalt="430742" height="379" width="317"]] 119 119 120 -[[image:image-20220525110604-2.png||_mstalt="427531"]] 119 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 120 +|=(% style="width: 167px;background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action** 121 +|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2; width:117px" %)Test uplink status|(% style="background-color:#f2f2f2; width:225px" %)((( 122 +If LHT65N is already Joined to rhe LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has external sensor connected,(% style="color:blue" %)**Blue led** (%%)will blink once. If LHT65N has not external sensor, (% style="color:red" %)**Red led**(%%) will blink once. 123 +))) 124 +|(% style="background-color:#f2f2f2; width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2; width:117px" %)Active Device|(% style="background-color:#f2f2f2; width:225px" %)((( 125 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. 126 +(% style="background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after join in network. 127 +))) 128 +|(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means LHT65N is in Deep Sleep Mode. 121 121 122 122 131 + 123 123 == 2.3 Example to join LoRaWAN network == 124 124 125 125 ... ... @@ -147,7 +147,7 @@ 147 147 Each LHT65N is shipped with a sticker with its device EUI, APP Key and APP EUI as below: 148 148 ))) 149 149 150 -[[image:image-202 20617150003-1.jpeg||_mstalt="5426434"]]159 +[[image:image-20230426083319-1.png]] 151 151 152 152 User can enter these keys in the LoRaWAN Server portal. Below is TTN V3 screenshot: 153 153 ... ... @@ -197,18 +197,18 @@ 197 197 After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once. 198 198 ))) 199 199 200 -(% border="1" cellspacing="4" style="background-color:#fff fcc;color:green;width:390px" %)201 -|=(% style="width: 60px;" %)((( 209 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:390px" %) 210 +|=(% style="width: 60px;background-color:#D9E2F3" %)((( 202 202 **Size(bytes)** 203 -)))|=(% style="width: 30px;" %)((( 212 +)))|=(% style="width: 30px;background-color:#D9E2F3" %)((( 204 204 **2** 205 -)))|=(% style="width: 100px;" %)((( 214 +)))|=(% style="width: 100px;background-color:#D9E2F3" %)((( 206 206 **2** 207 -)))|=(% style="width: 100px;" %)((( 216 +)))|=(% style="width: 100px;background-color:#D9E2F3" %)((( 208 208 **2** 209 -)))|=(% style="width: 50px;" %)((( 218 +)))|=(% style="width: 50px;background-color:#D9E2F3" %)((( 210 210 **1** 211 -)))|=(% style="width: 50px;" %)((( 220 +)))|=(% style="width: 50px;background-color:#D9E2F3" %)((( 212 212 **4** 213 213 ))) 214 214 |(% style="width:97px" %)((( ... ... @@ -251,6 +251,7 @@ 251 251 252 252 [[image:image-20220523152839-18.png||_mstalt="457613"]] 253 253 263 +(b)stands for binary 254 254 255 255 [[image:image-20220522235639-1.png||_mstalt="431392" height="139" width="727"]] 256 256 ... ... @@ -257,8 +257,8 @@ 257 257 258 258 Check the battery voltage for LHT65N. 259 259 260 -* BAT status=(0Xcba4>>14)&0xFF=11(B),very good 261 -* Battery Voltage =0xCB F6&0x3FFF=0x0BA4=2980mV270 +* BAT status=(0Xcba4>>14)&0xFF=11 (BIN) ,very good 271 +* Battery Voltage =0xCBA4&0x3FFF=0x0BA4=2980mV 262 262 263 263 === 2.4.3 Built-in Temperature === 264 264 ... ... @@ -314,6 +314,7 @@ 314 314 If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃ 315 315 316 316 327 + 317 317 ==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ==== 318 318 319 319 ... ... @@ -425,6 +425,7 @@ 425 425 [[image:image-20220628151143-7.png||_mstalt="431210"]] 426 426 427 427 439 + 428 428 ==== 2.4.6.4 Ext~=2 TMP117 Sensor (Since Firmware v1.3) ==== 429 429 430 430 ... ... @@ -441,6 +441,7 @@ 441 441 The external cable NE2 can be use for MOD4 and MOD8 442 442 443 443 456 + 444 444 ==== 2.4.6.5 Ext~=4 Interrupt Mode (Since Firmware v1.3) ==== 445 445 446 446 ... ... @@ -487,6 +487,7 @@ 487 487 [[image:image-20220906101145-3.png||_mstalt="428688"]] 488 488 489 489 503 + 490 490 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 491 491 492 492 ... ... @@ -852,17 +852,18 @@ 852 852 temperature fluctuation=05 853 853 854 854 855 - ====**Sampling multiple times and uplink together**====869 +**Sampling multiple times and uplink together** 856 856 857 857 **AT+WMOD=3,1,60,20,-16,32,1** 858 858 859 859 Explain: 860 860 861 -* Set Working Mode to **Mode 3** 862 -* Sampling Interval is **60**s. 863 -* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 864 -* Temperature alarm range is **-16** to **32**°C, 865 -* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 875 +* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3** 876 +* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 877 +* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s. 878 +* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 879 +* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C, 880 +* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 866 866 867 867 (% style="color:#4f81bd" %)**Downlink Command:** 868 868 ... ... @@ -870,7 +870,7 @@ 870 870 871 871 MOD=03 872 872 873 - EXT=01888 +TEMP=DS18B20 874 874 875 875 CITEMP=003C(S) 876 876 ... ... @@ -882,7 +882,6 @@ 882 882 883 883 ARTEMP=01 884 884 885 - 886 886 **Uplink payload( Fport=3)** 887 887 888 888 **Example: CBEA**01**0992**//0A41//**09C4** ... ... @@ -889,7 +889,7 @@ 889 889 890 890 BatV=CBEA 891 891 892 - EXT=01906 +TEMP=DS18B20 893 893 894 894 Temp1=0992 ~/~/ 24.50℃ 895 895 ... ... @@ -897,10 +897,9 @@ 897 897 898 898 Temp3=09C4 ~/~/ 25.00℃ 899 899 900 - 901 901 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 902 902 903 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ 916 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 904 904 ))) 905 905 906 906 ... ... @@ -1620,7 +1620,7 @@ 1620 1620 [[image:image-20220615153355-1.png||_mstalt="430222"]] 1621 1621 1622 1622 1623 -(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 1636 +(% style="color:blue" %)**Step1**(%%): Install [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]] first. 1624 1624 1625 1625 [[image:image-20220615170542-5.png||_mstalt="430638"]] 1626 1626 ... ... @@ -1686,7 +1686,7 @@ 1686 1686 [[image:image-20220623110706-1.png||_mstalt="427869"]] 1687 1687 1688 1688 1689 -(% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 1702 +(% style="color:blue" %)**Step1**(%%): Install [[TremoProgrammer>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AAAnJD_qGZ42bB52o4UmH9v9a/LHT65N%20Temperature%20%26%20Humidity%20Sensor/tool?dl=0&subfolder_nav_tracking=1]] first. 1690 1690 1691 1691 [[image:image-20220615170542-5.png||_mstalt="430638"]] 1692 1692 ... ... @@ -1772,6 +1772,3 @@ 1772 1772 (1) This device may not cause harmful interference; 1773 1773 1774 1774 (2) this device must accept any interference received, including interference that may cause undesired operation. 1775 - 1776 - 1777 -
- image-20230426083319-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +190.0 KB - Content