Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 227.1
edited by Bei Jinggeng
on 2023/02/01 11:11
on 2023/02/01 11:11
Change comment:
There is no comment for this version
To version 229.1
edited by Bei Jinggeng
on 2023/03/02 14:10
on 2023/03/02 14:10
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -46,7 +46,6 @@ 46 46 == 1.2 Features == 47 47 48 48 49 -* Wall mountable 50 50 * LoRaWAN v1.0.3 Class A protocol 51 51 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 52 52 * AT Commands to change parameters ... ... @@ -58,7 +58,6 @@ 58 58 * Tri-color LED to indicate working status 59 59 * Datalog feature (Max 3328 records) 60 60 61 - 62 62 == 1.3 Specification == 63 63 64 64 ... ... @@ -83,7 +83,6 @@ 83 83 * ±2°C accuracy from -55°C to +125°C 84 84 * Operating Range: -55 °C ~~ 125 °C 85 85 86 - 87 87 = 2. Connect LHT65N to IoT Server = 88 88 89 89 == 2.1 How does LHT65N work? == ... ... @@ -235,7 +235,6 @@ 235 235 * The 7th byte (EXT #): defines the external sensor model. 236 236 * The 8^^th^^ ~~ 11^^th^^ byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 237 237 238 - 239 239 === 2.4.1 Decoder in TTN V3 === 240 240 241 241 ... ... @@ -263,7 +263,6 @@ 263 263 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 264 264 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 265 265 266 - 267 267 === 2.4.3 Built-in Temperature === 268 268 269 269 ... ... @@ -275,7 +275,6 @@ 275 275 276 276 * Temperature: (0xF5C6-65536)/100=-26.18℃ 277 277 278 - 279 279 === 2.4.4 Built-in Humidity === 280 280 281 281 ... ... @@ -283,7 +283,6 @@ 283 283 284 284 * Humidity: 0x025C/10=60.4% 285 285 286 - 287 287 === 2.4.5 Ext # === 288 288 289 289 ... ... @@ -311,11 +311,16 @@ 311 311 312 312 * External temperature= (0xF54F-65536)/100=-27.37℃ 313 313 307 +F54F : (F54F & 8000 == 1) , temp = (F54F - 65536)/100 = 27.37℃ 308 + 309 +(0105 & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 310 + 314 314 The last 2 bytes of data are meaningless 315 315 316 316 If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃ 317 317 318 318 316 + 319 319 ==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ==== 320 320 321 321 ... ... @@ -379,7 +379,6 @@ 379 379 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 380 380 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 381 381 382 - 383 383 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 384 384 385 385 ... ... @@ -428,6 +428,7 @@ 428 428 [[image:image-20220628151143-7.png||_mstalt="431210"]] 429 429 430 430 428 + 431 431 ==== 2.4.6.4 Ext~=2 TMP117 Sensor (Since Firmware v1.3) ==== 432 432 433 433 ... ... @@ -444,6 +444,7 @@ 444 444 The external cable NE2 can be use for MOD4 and MOD8 445 445 446 446 445 + 447 447 ==== 2.4.6.5 Ext~=4 Interrupt Mode (Since Firmware v1.3) ==== 448 448 449 449 ... ... @@ -490,6 +490,7 @@ 490 490 [[image:image-20220906101145-3.png||_mstalt="428688"]] 491 491 492 492 492 + 493 493 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 494 494 495 495 ... ... @@ -855,17 +855,18 @@ 855 855 temperature fluctuation=05 856 856 857 857 858 - ====**Sampling multiple times and uplink together**====858 +**Sampling multiple times and uplink together** 859 859 860 860 **AT+WMOD=3,1,60,20,-16,32,1** 861 861 862 862 Explain: 863 863 864 -* Set Working Mode to **Mode 3** 865 -* Sampling Interval is **60**s. 866 -* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 867 -* Temperature alarm range is **-16** to **32**°C, 868 -* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 864 +* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3** 865 +* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 866 +* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s. 867 +* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 868 +* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C, 869 +* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 869 869 870 870 (% style="color:#4f81bd" %)**Downlink Command:** 871 871 ... ... @@ -873,7 +873,7 @@ 873 873 874 874 MOD=03 875 875 876 - EXT=01877 +TEMP=DS18B20 877 877 878 878 CITEMP=003C(S) 879 879 ... ... @@ -885,7 +885,6 @@ 885 885 886 886 ARTEMP=01 887 887 888 - 889 889 **Uplink payload( Fport=3)** 890 890 891 891 **Example: CBEA**01**0992**//0A41//**09C4** ... ... @@ -892,7 +892,7 @@ 892 892 893 893 BatV=CBEA 894 894 895 - EXT=01895 +TEMP=DS18B20 896 896 897 897 Temp1=0992 ~/~/ 24.50℃ 898 898 ... ... @@ -900,10 +900,9 @@ 900 900 901 901 Temp3=09C4 ~/~/ 25.00℃ 902 902 903 - 904 904 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 905 905 906 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ 905 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 907 907 ))) 908 908 909 909 ... ... @@ -962,7 +962,6 @@ 962 962 * RED LED when external sensor is not connected 963 963 * For each success downlink, the PURPLE LED will blink once 964 964 965 - 966 966 == 2.9 installation == 967 967 968 968 ... ... @@ -1015,7 +1015,6 @@ 1015 1015 * Operating Range: -40 ~~ 125 °C 1016 1016 * Working voltage 2.35v ~~ 5v 1017 1017 1018 - 1019 1019 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1020 1020 1021 1021 ... ... @@ -1084,7 +1084,6 @@ 1084 1084 1085 1085 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1086 1086 1087 - 1088 1088 == 4.2 Set External Sensor Mode == 1089 1089 1090 1090 ... ... @@ -1108,7 +1108,6 @@ 1108 1108 1109 1109 * 0xA20702003c: Same as AT+SETCNT=60 1110 1110 1111 - 1112 1112 == 4.3 Enable/Disable uplink Temperature probe ID == 1113 1113 1114 1114 ... ... @@ -1139,7 +1139,6 @@ 1139 1139 * **0xA800** **~-~->** AT+PID=0 1140 1140 * **0xA801** **~-~->** AT+PID=1 1141 1141 1142 - 1143 1143 == 4.4 Set Password == 1144 1144 1145 1145 ... ... @@ -1189,7 +1189,6 @@ 1189 1189 1190 1190 * There is no downlink command to set to Sleep mode. 1191 1191 1192 - 1193 1193 == 4.7 Set system time == 1194 1194 1195 1195 ... ... @@ -1293,7 +1293,6 @@ 1293 1293 1294 1294 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1295 1295 1296 - 1297 1297 == 4.13 Auto Send None-ACK messages == 1298 1298 1299 1299 ... ... @@ -1312,7 +1312,6 @@ 1312 1312 1313 1313 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1314 1314 1315 - 1316 1316 == 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1317 1317 1318 1318 ... ... @@ -1757,7 +1757,6 @@ 1757 1757 1758 1758 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1759 1759 1760 - 1761 1761 = 8. Packing Info = 1762 1762 1763 1763 ... ... @@ -1771,13 +1771,11 @@ 1771 1771 * Device Size: 10 x 10 x 3.5 mm 1772 1772 * Device Weight: 120.5g 1773 1773 1774 - 1775 1775 = 9. Reference material = 1776 1776 1777 1777 1778 1778 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 1779 1779 1780 - 1781 1781 = 10. FCC Warning = 1782 1782 1783 1783