Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 226.2
edited by Xiaoling
on 2023/01/29 11:46
on 2023/01/29 11:46
Change comment:
There is no comment for this version
To version 230.1
edited by Bei Jinggeng
on 2023/03/13 09:40
on 2023/03/13 09:40
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -46,7 +46,6 @@ 46 46 == 1.2 Features == 47 47 48 48 49 -* Wall mountable 50 50 * LoRaWAN v1.0.3 Class A protocol 51 51 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 52 52 * AT Commands to change parameters ... ... @@ -59,7 +59,6 @@ 59 59 * Datalog feature (Max 3328 records) 60 60 61 61 62 - 63 63 == 1.3 Specification == 64 64 65 65 ... ... @@ -85,7 +85,6 @@ 85 85 * Operating Range: -55 °C ~~ 125 °C 86 86 87 87 88 - 89 89 = 2. Connect LHT65N to IoT Server = 90 90 91 91 == 2.1 How does LHT65N work? == ... ... @@ -238,7 +238,6 @@ 238 238 * The 8^^th^^ ~~ 11^^th^^ byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 239 239 240 240 241 - 242 242 === 2.4.1 Decoder in TTN V3 === 243 243 244 244 ... ... @@ -263,11 +263,10 @@ 263 263 264 264 Check the battery voltage for LHT65N. 265 265 266 -* BAT status=(0Xcba4>>14)&0xFF=11(B),very good 267 -* Battery Voltage =0xCB F6&0x3FFF=0x0BA4=2980mV262 +* BAT status=(0Xcba4>>14)&0xFF=11(DEC) / B(HEX) ,very good 263 +* Battery Voltage =0xCBA4&0x3FFF=0x0BA4=2980mV 268 268 269 269 270 - 271 271 === 2.4.3 Built-in Temperature === 272 272 273 273 ... ... @@ -280,7 +280,6 @@ 280 280 * Temperature: (0xF5C6-65536)/100=-26.18℃ 281 281 282 282 283 - 284 284 === 2.4.4 Built-in Humidity === 285 285 286 286 ... ... @@ -289,7 +289,6 @@ 289 289 * Humidity: 0x025C/10=60.4% 290 290 291 291 292 - 293 293 === 2.4.5 Ext # === 294 294 295 295 ... ... @@ -317,11 +317,16 @@ 317 317 318 318 * External temperature= (0xF54F-65536)/100=-27.37℃ 319 319 313 +F54F : (F54F & 8000 == 1) , temp = (F54F - 65536)/100 = 27.37℃ 314 + 315 +(0105 & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 316 + 320 320 The last 2 bytes of data are meaningless 321 321 322 322 If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃ 323 323 324 324 322 + 325 325 ==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ==== 326 326 327 327 ... ... @@ -386,7 +386,6 @@ 386 386 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 387 387 388 388 389 - 390 390 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 391 391 392 392 ... ... @@ -435,6 +435,7 @@ 435 435 [[image:image-20220628151143-7.png||_mstalt="431210"]] 436 436 437 437 435 + 438 438 ==== 2.4.6.4 Ext~=2 TMP117 Sensor (Since Firmware v1.3) ==== 439 439 440 440 ... ... @@ -451,6 +451,7 @@ 451 451 The external cable NE2 can be use for MOD4 and MOD8 452 452 453 453 452 + 454 454 ==== 2.4.6.5 Ext~=4 Interrupt Mode (Since Firmware v1.3) ==== 455 455 456 456 ... ... @@ -497,6 +497,7 @@ 497 497 [[image:image-20220906101145-3.png||_mstalt="428688"]] 498 498 499 499 499 + 500 500 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 501 501 502 502 ... ... @@ -862,17 +862,18 @@ 862 862 temperature fluctuation=05 863 863 864 864 865 - ====**Sampling multiple times and uplink together**====865 +**Sampling multiple times and uplink together** 866 866 867 867 **AT+WMOD=3,1,60,20,-16,32,1** 868 868 869 869 Explain: 870 870 871 -* Set Working Mode to **Mode 3** 872 -* Sampling Interval is **60**s. 873 -* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 874 -* Temperature alarm range is **-16** to **32**°C, 875 -* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 871 +* (% style="color:#037691" %)**parameter1:**(%%)Set Working Mode to **Mode 3** 872 +* (% style="color:#037691" %)**parameter2:**(%%) Set the temperature sampling mode to** 1**(1:DS18B20;2:TMP117;3:** **Internal GXHT30). 873 +* (% style="color:#037691" %)**parameter3:**(%%)Sampling Interval is **60**s. 874 +* (% style="color:#037691" %)**parameter4:**(%%)When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 875 +* (% style="color:#037691" %)**parameter5 & parameter6:**(%%)Temperature alarm range is **-16** to **32**°C, 876 +* (% style="color:#037691" %)**parameter7:**(%%) 1 to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 876 876 877 877 (% style="color:#4f81bd" %)**Downlink Command:** 878 878 ... ... @@ -880,7 +880,7 @@ 880 880 881 881 MOD=03 882 882 883 - EXT=01884 +TEMP=DS18B20 884 884 885 885 CITEMP=003C(S) 886 886 ... ... @@ -892,7 +892,6 @@ 892 892 893 893 ARTEMP=01 894 894 895 - 896 896 **Uplink payload( Fport=3)** 897 897 898 898 **Example: CBEA**01**0992**//0A41//**09C4** ... ... @@ -899,7 +899,7 @@ 899 899 900 900 BatV=CBEA 901 901 902 - EXT=01902 +TEMP=DS18B20 903 903 904 904 Temp1=0992 ~/~/ 24.50℃ 905 905 ... ... @@ -907,10 +907,9 @@ 907 907 908 908 Temp3=09C4 ~/~/ 25.00℃ 909 909 910 - 911 911 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 912 912 913 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ 912 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 914 914 ))) 915 915 916 916 ... ... @@ -970,7 +970,6 @@ 970 970 * For each success downlink, the PURPLE LED will blink once 971 971 972 972 973 - 974 974 == 2.9 installation == 975 975 976 976 ... ... @@ -1024,7 +1024,6 @@ 1024 1024 * Working voltage 2.35v ~~ 5v 1025 1025 1026 1026 1027 - 1028 1028 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1029 1029 1030 1030 ... ... @@ -1094,7 +1094,6 @@ 1094 1094 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1095 1095 1096 1096 1097 - 1098 1098 == 4.2 Set External Sensor Mode == 1099 1099 1100 1100 ... ... @@ -1119,7 +1119,6 @@ 1119 1119 * 0xA20702003c: Same as AT+SETCNT=60 1120 1120 1121 1121 1122 - 1123 1123 == 4.3 Enable/Disable uplink Temperature probe ID == 1124 1124 1125 1125 ... ... @@ -1151,7 +1151,6 @@ 1151 1151 * **0xA801** **~-~->** AT+PID=1 1152 1152 1153 1153 1154 - 1155 1155 == 4.4 Set Password == 1156 1156 1157 1157 ... ... @@ -1202,7 +1202,6 @@ 1202 1202 * There is no downlink command to set to Sleep mode. 1203 1203 1204 1204 1205 - 1206 1206 == 4.7 Set system time == 1207 1207 1208 1208 ... ... @@ -1307,7 +1307,6 @@ 1307 1307 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1308 1308 1309 1309 1310 - 1311 1311 == 4.13 Auto Send None-ACK messages == 1312 1312 1313 1313 ... ... @@ -1327,7 +1327,6 @@ 1327 1327 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1328 1328 1329 1329 1330 - 1331 1331 == 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1332 1332 1333 1333 ... ... @@ -1773,7 +1773,6 @@ 1773 1773 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1774 1774 1775 1775 1776 - 1777 1777 = 8. Packing Info = 1778 1778 1779 1779 ... ... @@ -1788,7 +1788,6 @@ 1788 1788 * Device Weight: 120.5g 1789 1789 1790 1790 1791 - 1792 1792 = 9. Reference material = 1793 1793 1794 1794 ... ... @@ -1795,7 +1795,6 @@ 1795 1795 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0]] 1796 1796 1797 1797 1798 - 1799 1799 = 10. FCC Warning = 1800 1800 1801 1801