Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 222.1
edited by Edwin Chen
on 2022/11/19 11:48
on 2022/11/19 11:48
Change comment:
There is no comment for this version
To version 218.1
edited by Bei Jinggeng
on 2022/11/16 15:24
on 2022/11/16 15:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -61,6 +61,7 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 + 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -85,6 +85,7 @@ 85 85 * ±2°C accuracy from -55°C to +125°C 86 86 * Operating Range: -55 °C ~~ 125 °C 87 87 89 + 88 88 = 2. Connect LHT65N to IoT Server = 89 89 90 90 ... ... @@ -242,6 +242,7 @@ 242 242 * The 7th byte (EXT #): defines the external sensor model. 243 243 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 244 244 247 + 245 245 === 2.4.1 Decoder in TTN V3 === 246 246 247 247 ... ... @@ -270,6 +270,7 @@ 270 270 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 271 271 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 272 272 276 + 273 273 === 2.4.3 Built-in Temperature === 274 274 275 275 ... ... @@ -281,6 +281,7 @@ 281 281 282 282 * Temperature: (0xF5C6-65536)/100=-26.18℃ 283 283 288 + 284 284 === 2.4.4 Built-in Humidity === 285 285 286 286 ... ... @@ -288,6 +288,7 @@ 288 288 289 289 * Humidity: 0x025C/10=60.4% 290 290 296 + 291 291 === 2.4.5 Ext # === 292 292 293 293 ... ... @@ -386,6 +386,7 @@ 386 386 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 387 387 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 388 388 395 + 389 389 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 390 390 391 391 ... ... @@ -875,17 +875,8 @@ 875 875 876 876 ==== **Sampling multiple times and uplink together** ==== 877 877 878 -**AT+WMOD=3,1,60,20,-16,32,1** 885 +**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -16 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 879 879 880 -Explain: 881 - 882 -* Set Working Mode to **Mode 3** 883 -* Sampling Interval is **60**s. 884 -* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink) 885 -* Temperature alarm range is **-16** to **32**°C, 886 -* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately if temperate exceeds the Alarm range. 887 - 888 - 889 889 (% style="color:#4f81bd" %)**Downlink Command:** 890 890 891 891 **Example: **A50301003C14FFF0002001 ... ... @@ -907,7 +907,7 @@ 907 907 908 908 **Uplink payload( Fport=3)** 909 909 910 -**Example: **01**0992**//0A41//**09C4**908 +**Example: **CBEA0109920A4109C4 911 911 912 912 BatV=CBEA 913 913 ... ... @@ -1039,6 +1039,7 @@ 1039 1039 * Operating Range: -40 ~~ 125 °C 1040 1040 * Working voltage 2.35v ~~ 5v 1041 1041 1040 + 1042 1042 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1043 1043 1044 1044 ... ... @@ -1108,6 +1108,7 @@ 1108 1108 1109 1109 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1110 1110 1110 + 1111 1111 == 4.2 Set External Sensor Mode == 1112 1112 1113 1113 ... ... @@ -1131,6 +1131,7 @@ 1131 1131 1132 1132 * 0xA20702003c: Same as AT+SETCNT=60 1133 1133 1134 + 1134 1134 == 4.3 Enable/Disable uplink Temperature probe ID == 1135 1135 1136 1136 ... ... @@ -1161,6 +1161,7 @@ 1161 1161 * **0xA800** **~-~->** AT+PID=0 1162 1162 * **0xA801** **~-~->** AT+PID=1 1163 1163 1165 + 1164 1164 == 4.4 Set Password == 1165 1165 1166 1166 ... ... @@ -1212,6 +1212,7 @@ 1212 1212 1213 1213 * There is no downlink command to set to Sleep mode. 1214 1214 1217 + 1215 1215 == 4.7 Set system time == 1216 1216 1217 1217 ... ... @@ -1320,6 +1320,7 @@ 1320 1320 1321 1321 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1322 1322 1326 + 1323 1323 == 4.13 Auto Send None-ACK messages == 1324 1324 1325 1325 ... ... @@ -1338,6 +1338,7 @@ 1338 1338 1339 1339 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1340 1340 1345 + 1341 1341 == 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1342 1342 1343 1343 ... ... @@ -1811,7 +1811,7 @@ 1811 1811 [[image:image-20220623113959-5.png||height="528" width="397"]] 1812 1812 1813 1813 (% _msthash="506146" _msttexthash="52173160" %) 1814 -Connect A 8and GND with Dupont wire for a while and then separate,enter reset mode1819 +Connect A5 and GND with Dupont wire for a while and then separate 1815 1815 1816 1816 1817 1817 ... ... @@ -1828,7 +1828,7 @@ 1828 1828 [[image:image-20220620160723-8.png]] 1829 1829 1830 1830 1831 -Finally, Disconnect 3.3v,Connect A8 and GND with Dupont wirefor a while and thenseparate,exitresetmode1836 +Finally,restart reset device again 1832 1832 1833 1833 1834 1834 ... ... @@ -1852,6 +1852,7 @@ 1852 1852 1853 1853 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1854 1854 1860 + 1855 1855 = 8. Packing Info = 1856 1856 1857 1857 ... ... @@ -1862,14 +1862,16 @@ 1862 1862 1863 1863 **Dimension and weight**: 1864 1864 1865 -* Device Size: 10 x 10 x 3.5 m m1871 +* Device Size: 10 x 10 x 3.5 cm 1866 1866 * Device Weight: 120.5g 1867 1867 1874 + 1868 1868 = 9. Reference material = 1869 1869 1870 1870 1871 1871 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1872 1872 1880 + 1873 1873 = 10. FCC Warning = 1874 1874 1875 1875