... ... @@ -875,8 +875,17 @@
875 875  
876 876  ==== **Sampling multiple times and uplink together** ====
877 877  
878 -**AT+WMOD=3,1,60,20,-16,32,1**  ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -16 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately.
878 +**AT+WMOD=3,1,60,20,-16,32,1** 
879 879  
880 +Explain:
881 +
882 +* Set Working Mode to **Mode 3**
883 +* Sampling Interval is **60**s.
884 +* When there is **20** sampling dats, Device will send these data via one uplink. (max value is 60, means max 60 sampling in one uplink)
885 +* Temperature alarm range is **-16** to **32**°C,
886 +* **1** to enable temperature alarm, **0** to disable the temperature alarm. If alarm is enabled, a data will be sent immediately  if temperate exceeds the Alarm range.
887 +
888 +
880 880  (% style="color:#4f81bd" %)**Downlink Command:**
881 881  
882 882  **Example: **A50301003C14FFF0002001
... ... @@ -898,7 +898,7 @@
898 898  
899 899  **Uplink payload( Fport=3)**
900 900  
901 -**Example: **CBEA0109920A4109C4
910 +**Example: CBEA**01**0992**//0A41//**09C4**
902 902  
903 903  BatV=CBEA
904 904