Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 221.1
edited by Bei Jinggeng
on 2022/11/17 16:54
on 2022/11/17 16:54
Change comment:
There is no comment for this version
To version 218.1
edited by Bei Jinggeng
on 2022/11/16 15:24
on 2022/11/16 15:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,6 +61,7 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 + 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -85,6 +85,7 @@ 85 85 * ±2°C accuracy from -55°C to +125°C 86 86 * Operating Range: -55 °C ~~ 125 °C 87 87 89 + 88 88 = 2. Connect LHT65N to IoT Server = 89 89 90 90 ... ... @@ -242,6 +242,7 @@ 242 242 * The 7th byte (EXT #): defines the external sensor model. 243 243 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 244 244 247 + 245 245 === 2.4.1 Decoder in TTN V3 === 246 246 247 247 ... ... @@ -270,6 +270,7 @@ 270 270 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 271 271 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 272 272 276 + 273 273 === 2.4.3 Built-in Temperature === 274 274 275 275 ... ... @@ -281,6 +281,7 @@ 281 281 282 282 * Temperature: (0xF5C6-65536)/100=-26.18℃ 283 283 288 + 284 284 === 2.4.4 Built-in Humidity === 285 285 286 286 ... ... @@ -288,6 +288,7 @@ 288 288 289 289 * Humidity: 0x025C/10=60.4% 290 290 296 + 291 291 === 2.4.5 Ext # === 292 292 293 293 ... ... @@ -386,6 +386,7 @@ 386 386 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 387 387 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 388 388 395 + 389 389 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 390 390 391 391 ... ... @@ -1030,6 +1030,7 @@ 1030 1030 * Operating Range: -40 ~~ 125 °C 1031 1031 * Working voltage 2.35v ~~ 5v 1032 1032 1040 + 1033 1033 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1034 1034 1035 1035 ... ... @@ -1099,6 +1099,7 @@ 1099 1099 1100 1100 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1101 1101 1110 + 1102 1102 == 4.2 Set External Sensor Mode == 1103 1103 1104 1104 ... ... @@ -1122,6 +1122,7 @@ 1122 1122 1123 1123 * 0xA20702003c: Same as AT+SETCNT=60 1124 1124 1134 + 1125 1125 == 4.3 Enable/Disable uplink Temperature probe ID == 1126 1126 1127 1127 ... ... @@ -1152,6 +1152,7 @@ 1152 1152 * **0xA800** **~-~->** AT+PID=0 1153 1153 * **0xA801** **~-~->** AT+PID=1 1154 1154 1165 + 1155 1155 == 4.4 Set Password == 1156 1156 1157 1157 ... ... @@ -1203,6 +1203,7 @@ 1203 1203 1204 1204 * There is no downlink command to set to Sleep mode. 1205 1205 1217 + 1206 1206 == 4.7 Set system time == 1207 1207 1208 1208 ... ... @@ -1311,6 +1311,7 @@ 1311 1311 1312 1312 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1313 1313 1326 + 1314 1314 == 4.13 Auto Send None-ACK messages == 1315 1315 1316 1316 ... ... @@ -1329,6 +1329,7 @@ 1329 1329 1330 1330 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1331 1331 1345 + 1332 1332 == 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1333 1333 1334 1334 ... ... @@ -1802,7 +1802,7 @@ 1802 1802 [[image:image-20220623113959-5.png||height="528" width="397"]] 1803 1803 1804 1804 (% _msthash="506146" _msttexthash="52173160" %) 1805 -Connect A 8and GND with Dupont wire for a while and then separate,enter reset mode1819 +Connect A5 and GND with Dupont wire for a while and then separate 1806 1806 1807 1807 1808 1808 ... ... @@ -1819,7 +1819,7 @@ 1819 1819 [[image:image-20220620160723-8.png]] 1820 1820 1821 1821 1822 -Finally, Disconnect 3.3v,Connect A8 and GND with Dupont wirefor a while and thenseparate,exitresetmode1836 +Finally,restart reset device again 1823 1823 1824 1824 1825 1825 ... ... @@ -1843,6 +1843,7 @@ 1843 1843 1844 1844 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1845 1845 1860 + 1846 1846 = 8. Packing Info = 1847 1847 1848 1848 ... ... @@ -1853,14 +1853,16 @@ 1853 1853 1854 1854 **Dimension and weight**: 1855 1855 1856 -* Device Size: 10 x 10 x 3.5 m m1871 +* Device Size: 10 x 10 x 3.5 cm 1857 1857 * Device Weight: 120.5g 1858 1858 1874 + 1859 1859 = 9. Reference material = 1860 1860 1861 1861 1862 1862 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1863 1863 1880 + 1864 1864 = 10. FCC Warning = 1865 1865 1866 1866