Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 218.1
edited by Bei Jinggeng
on 2022/11/16 15:24
on 2022/11/16 15:24
Change comment:
There is no comment for this version
To version 221.1
edited by Bei Jinggeng
on 2022/11/17 16:54
on 2022/11/17 16:54
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,7 +61,6 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 - 65 65 == 1.3 Specification == 66 66 67 67 ... ... @@ -86,7 +86,6 @@ 86 86 * ±2°C accuracy from -55°C to +125°C 87 87 * Operating Range: -55 °C ~~ 125 °C 88 88 89 - 90 90 = 2. Connect LHT65N to IoT Server = 91 91 92 92 ... ... @@ -244,7 +244,6 @@ 244 244 * The 7th byte (EXT #): defines the external sensor model. 245 245 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 246 246 247 - 248 248 === 2.4.1 Decoder in TTN V3 === 249 249 250 250 ... ... @@ -273,7 +273,6 @@ 273 273 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 274 274 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 275 275 276 - 277 277 === 2.4.3 Built-in Temperature === 278 278 279 279 ... ... @@ -285,7 +285,6 @@ 285 285 286 286 * Temperature: (0xF5C6-65536)/100=-26.18℃ 287 287 288 - 289 289 === 2.4.4 Built-in Humidity === 290 290 291 291 ... ... @@ -293,7 +293,6 @@ 293 293 294 294 * Humidity: 0x025C/10=60.4% 295 295 296 - 297 297 === 2.4.5 Ext # === 298 298 299 299 ... ... @@ -392,7 +392,6 @@ 392 392 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 393 393 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 394 394 395 - 396 396 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 397 397 398 398 ... ... @@ -1037,7 +1037,6 @@ 1037 1037 * Operating Range: -40 ~~ 125 °C 1038 1038 * Working voltage 2.35v ~~ 5v 1039 1039 1040 - 1041 1041 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1042 1042 1043 1043 ... ... @@ -1107,7 +1107,6 @@ 1107 1107 1108 1108 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1109 1109 1110 - 1111 1111 == 4.2 Set External Sensor Mode == 1112 1112 1113 1113 ... ... @@ -1131,7 +1131,6 @@ 1131 1131 1132 1132 * 0xA20702003c: Same as AT+SETCNT=60 1133 1133 1134 - 1135 1135 == 4.3 Enable/Disable uplink Temperature probe ID == 1136 1136 1137 1137 ... ... @@ -1162,7 +1162,6 @@ 1162 1162 * **0xA800** **~-~->** AT+PID=0 1163 1163 * **0xA801** **~-~->** AT+PID=1 1164 1164 1165 - 1166 1166 == 4.4 Set Password == 1167 1167 1168 1168 ... ... @@ -1214,7 +1214,6 @@ 1214 1214 1215 1215 * There is no downlink command to set to Sleep mode. 1216 1216 1217 - 1218 1218 == 4.7 Set system time == 1219 1219 1220 1220 ... ... @@ -1323,7 +1323,6 @@ 1323 1323 1324 1324 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1325 1325 1326 - 1327 1327 == 4.13 Auto Send None-ACK messages == 1328 1328 1329 1329 ... ... @@ -1342,7 +1342,6 @@ 1342 1342 1343 1343 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1344 1344 1345 - 1346 1346 == 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1347 1347 1348 1348 ... ... @@ -1816,7 +1816,7 @@ 1816 1816 [[image:image-20220623113959-5.png||height="528" width="397"]] 1817 1817 1818 1818 (% _msthash="506146" _msttexthash="52173160" %) 1819 -Connect A 5and GND with Dupont wire for a while and then separate1805 +Connect A8 and GND with Dupont wire for a while and then separate,enter reset mode 1820 1820 1821 1821 1822 1822 ... ... @@ -1833,7 +1833,7 @@ 1833 1833 [[image:image-20220620160723-8.png]] 1834 1834 1835 1835 1836 -Finally, restart resetdeviceagain1822 +Finally,Disconnect 3.3v,Connect A8 and GND with Dupont wire for a while and then separate,exit reset mode 1837 1837 1838 1838 1839 1839 ... ... @@ -1857,7 +1857,6 @@ 1857 1857 1858 1858 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1859 1859 1860 - 1861 1861 = 8. Packing Info = 1862 1862 1863 1863 ... ... @@ -1868,16 +1868,14 @@ 1868 1868 1869 1869 **Dimension and weight**: 1870 1870 1871 -* Device Size: 10 x 10 x 3.5 cm1856 +* Device Size: 10 x 10 x 3.5 mm 1872 1872 * Device Weight: 120.5g 1873 1873 1874 - 1875 1875 = 9. Reference material = 1876 1876 1877 1877 1878 1878 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1879 1879 1880 - 1881 1881 = 10. FCC Warning = 1882 1882 1883 1883