Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 218.1
edited by Bei Jinggeng
on 2022/11/16 15:24
on 2022/11/16 15:24
Change comment:
There is no comment for this version
To version 216.1
edited by Bei Jinggeng
on 2022/11/11 09:19
on 2022/11/11 09:19
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,7 +61,6 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 - 65 65 == 1.3 Specification == 66 66 67 67 ... ... @@ -86,7 +86,6 @@ 86 86 * ±2°C accuracy from -55°C to +125°C 87 87 * Operating Range: -55 °C ~~ 125 °C 88 88 89 - 90 90 = 2. Connect LHT65N to IoT Server = 91 91 92 92 ... ... @@ -186,6 +186,7 @@ 186 186 187 187 188 188 187 + 189 189 === 2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. === 190 190 191 191 ... ... @@ -244,7 +244,6 @@ 244 244 * The 7th byte (EXT #): defines the external sensor model. 245 245 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 246 246 247 - 248 248 === 2.4.1 Decoder in TTN V3 === 249 249 250 250 ... ... @@ -273,7 +273,6 @@ 273 273 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 274 274 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 275 275 276 - 277 277 === 2.4.3 Built-in Temperature === 278 278 279 279 ... ... @@ -285,7 +285,6 @@ 285 285 286 286 * Temperature: (0xF5C6-65536)/100=-26.18℃ 287 287 288 - 289 289 === 2.4.4 Built-in Humidity === 290 290 291 291 ... ... @@ -293,7 +293,6 @@ 293 293 294 294 * Humidity: 0x025C/10=60.4% 295 295 296 - 297 297 === 2.4.5 Ext # === 298 298 299 299 ... ... @@ -392,7 +392,6 @@ 392 392 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 393 393 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 394 394 395 - 396 396 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 397 397 398 398 ... ... @@ -681,8 +681,10 @@ 681 681 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 682 682 ))) 683 683 678 +((( 679 + 680 +))) 684 684 685 - 686 686 ((( 687 687 **2. Manually Set Time** 688 688 ))) ... ... @@ -882,7 +882,7 @@ 882 882 883 883 ==== **Sampling multiple times and uplink together** ==== 884 884 885 -**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -1 6to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately.881 +**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -10 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 886 886 887 887 (% style="color:#4f81bd" %)**Downlink Command:** 888 888 ... ... @@ -921,11 +921,16 @@ 921 921 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 922 922 923 923 (% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 924 -))) 925 925 926 926 922 + 923 +))) 924 + 925 +((( 927 927 === 2.7.2 ALARM MODE ( Before v1.3.1 firmware) === 928 928 928 + 929 +))) 929 929 930 930 (% _mstvisible="1" class="box infomessage" %) 931 931 ((( ... ... @@ -1037,7 +1037,6 @@ 1037 1037 * Operating Range: -40 ~~ 125 °C 1038 1038 * Working voltage 2.35v ~~ 5v 1039 1039 1040 - 1041 1041 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1042 1042 1043 1043 ... ... @@ -1107,7 +1107,6 @@ 1107 1107 1108 1108 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1109 1109 1110 - 1111 1111 == 4.2 Set External Sensor Mode == 1112 1112 1113 1113 ... ... @@ -1131,7 +1131,6 @@ 1131 1131 1132 1132 * 0xA20702003c: Same as AT+SETCNT=60 1133 1133 1134 - 1135 1135 == 4.3 Enable/Disable uplink Temperature probe ID == 1136 1136 1137 1137 ... ... @@ -1162,7 +1162,6 @@ 1162 1162 * **0xA800** **~-~->** AT+PID=0 1163 1163 * **0xA801** **~-~->** AT+PID=1 1164 1164 1165 - 1166 1166 == 4.4 Set Password == 1167 1167 1168 1168 ... ... @@ -1214,7 +1214,6 @@ 1214 1214 1215 1215 * There is no downlink command to set to Sleep mode. 1216 1216 1217 - 1218 1218 == 4.7 Set system time == 1219 1219 1220 1220 ... ... @@ -1323,7 +1323,6 @@ 1323 1323 1324 1324 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1325 1325 1326 - 1327 1327 == 4.13 Auto Send None-ACK messages == 1328 1328 1329 1329 ... ... @@ -1342,7 +1342,6 @@ 1342 1342 1343 1343 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1344 1344 1345 - 1346 1346 == 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1347 1347 1348 1348 ... ... @@ -1388,8 +1388,6 @@ 1388 1388 1389 1389 0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 ) 1390 1390 1391 -0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Need to convert -16 to -1600 for calculation,-1600(DEC)=FFFFFFFFFFFFF9C0(HEX) FFFFFFFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX)) 1392 - 1393 1393 0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = second byte, third byte, fourth byte) 1394 1394 1395 1395 0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02. ... ... @@ -1402,17 +1402,22 @@ 1402 1402 == 5.1 Battery Type == 1403 1403 1404 1404 1405 - 1406 1406 ((( 1398 +((( 1407 1407 LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 1408 1408 ))) 1401 +))) 1409 1409 1403 +((( 1404 + 1405 +))) 1410 1410 1411 - 1412 1412 ((( 1408 +((( 1413 1413 The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1414 1414 [[image:image-20220515075034-1.png||_mstalt="428961" _mstvisible="4" height="208" width="644"]] 1415 1415 ))) 1412 +))) 1416 1416 1417 1417 The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 1418 1418 ... ... @@ -1435,6 +1435,9 @@ 1435 1435 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 1436 1436 ))) 1437 1437 1435 +((( 1436 + 1437 +))) 1438 1438 1439 1439 ((( 1440 1440 A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] ... ... @@ -1816,7 +1816,7 @@ 1816 1816 [[image:image-20220623113959-5.png||height="528" width="397"]] 1817 1817 1818 1818 (% _msthash="506146" _msttexthash="52173160" %) 1819 - ConnectA5andGNDwithDupontwireforawhileandthen separate1819 +Press and hold the start key to restart and enter (% _mstvisible="1" %)bootlaod(%%) mode. 1820 1820 1821 1821 1822 1822 ... ... @@ -1857,7 +1857,6 @@ 1857 1857 1858 1858 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1859 1859 1860 - 1861 1861 = 8. Packing Info = 1862 1862 1863 1863 ... ... @@ -1871,13 +1871,11 @@ 1871 1871 * Device Size: 10 x 10 x 3.5 cm 1872 1872 * Device Weight: 120.5g 1873 1873 1874 - 1875 1875 = 9. Reference material = 1876 1876 1877 1877 1878 1878 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1879 1879 1880 - 1881 1881 = 10. FCC Warning = 1882 1882 1883 1883