Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 218.1
edited by Bei Jinggeng
on 2022/11/16 15:24
on 2022/11/16 15:24
Change comment:
There is no comment for this version
To version 214.1
edited by Edwin Chen
on 2022/11/03 23:38
on 2022/11/03 23:38
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Edwin - Content
-
... ... @@ -186,6 +186,7 @@ 186 186 187 187 188 188 189 + 189 189 === 2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. === 190 190 191 191 ... ... @@ -681,8 +681,10 @@ 681 681 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 682 682 ))) 683 683 685 +((( 686 + 687 +))) 684 684 685 - 686 686 ((( 687 687 **2. Manually Set Time** 688 688 ))) ... ... @@ -786,7 +786,7 @@ 786 786 787 787 788 788 789 -== 2.7 Alarm Mode & Feature "Multi sampling, one uplink"==792 +== 2.7 Alarm Mode == 790 790 791 791 792 792 ((( ... ... @@ -880,9 +880,9 @@ 880 880 temperature fluctuation=05 881 881 882 882 883 - ====**Samplingmultiple times anduplinktogether**====886 +**Collect multiple times and send once** 884 884 885 -**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -1 6to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately.888 +**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -10 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 886 886 887 887 (% style="color:#4f81bd" %)**Downlink Command:** 888 888 ... ... @@ -921,11 +921,16 @@ 921 921 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 922 922 923 923 (% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 924 -))) 925 925 926 926 929 + 930 +))) 931 + 932 +((( 927 927 === 2.7.2 ALARM MODE ( Before v1.3.1 firmware) === 928 928 935 + 936 +))) 929 929 930 930 (% _mstvisible="1" class="box infomessage" %) 931 931 ((( ... ... @@ -980,6 +980,7 @@ 980 980 * RED LED when external sensor is not connected 981 981 * For each success downlink, the PURPLE LED will blink once 982 982 991 + 983 983 == 2.9 installation == 984 984 985 985 ... ... @@ -1343,7 +1343,7 @@ 1343 1343 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1344 1344 1345 1345 1346 -== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm (Sincefirmware 1.3.0)==1355 +== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm == 1347 1347 1348 1348 1349 1349 Feature: Set internal and external temperature sensor alarms. ... ... @@ -1388,8 +1388,6 @@ 1388 1388 1389 1389 0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 ) 1390 1390 1391 -0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Need to convert -16 to -1600 for calculation,-1600(DEC)=FFFFFFFFFFFFF9C0(HEX) FFFFFFFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX)) 1392 - 1393 1393 0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = second byte, third byte, fourth byte) 1394 1394 1395 1395 0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02. ... ... @@ -1402,17 +1402,22 @@ 1402 1402 == 5.1 Battery Type == 1403 1403 1404 1404 1405 - 1406 1406 ((( 1413 +((( 1407 1407 LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 1408 1408 ))) 1416 +))) 1409 1409 1418 +((( 1419 + 1420 +))) 1410 1410 1411 - 1412 1412 ((( 1423 +((( 1413 1413 The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1414 1414 [[image:image-20220515075034-1.png||_mstalt="428961" _mstvisible="4" height="208" width="644"]] 1415 1415 ))) 1427 +))) 1416 1416 1417 1417 The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 1418 1418 ... ... @@ -1435,6 +1435,9 @@ 1435 1435 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 1436 1436 ))) 1437 1437 1450 +((( 1451 + 1452 +))) 1438 1438 1439 1439 ((( 1440 1440 A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] ... ... @@ -1816,7 +1816,7 @@ 1816 1816 [[image:image-20220623113959-5.png||height="528" width="397"]] 1817 1817 1818 1818 (% _msthash="506146" _msttexthash="52173160" %) 1819 - ConnectA5andGNDwithDupontwireforawhileandthen separate1834 +Press and hold the start key to restart and enter (% _mstvisible="1" %)bootlaod(%%) mode. 1820 1820 1821 1821 1822 1822