Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 216.1
edited by Bei Jinggeng
on 2022/11/11 09:19
on 2022/11/11 09:19
Change comment:
There is no comment for this version
To version 212.1
edited by Bei Jinggeng
on 2022/11/01 17:55
on 2022/11/01 17:55
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -500,6 +500,7 @@ 500 500 501 501 502 502 503 + 503 503 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 504 504 505 505 ... ... @@ -619,7 +619,6 @@ 619 619 620 620 (% style="color:blue" %)**Method 2: **(%%)Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 621 621 622 - 623 623 (% style="color:red" %)**Note for method 2:** 624 624 625 625 * a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. ... ... @@ -782,7 +782,7 @@ 782 782 783 783 784 784 785 -== 2.7 Alarm Mode & Feature "Multi sampling, one uplink"==785 +== 2.7 Alarm Mode == 786 786 787 787 788 788 ((( ... ... @@ -796,7 +796,6 @@ 796 796 797 797 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 798 798 799 - 800 800 **Internal GXHT30 temperature alarm** 801 801 802 802 ((( ... ... @@ -828,12 +828,11 @@ 828 828 829 829 AT+LEDALARM=1 : 3601 830 830 831 - 832 832 (% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 833 833 834 834 Total bytes: 8 bytes 835 835 836 -**Example: 834 +**Example:**AA0100010001003C 837 837 838 838 WMOD=01 839 839 ... ... @@ -846,11 +846,11 @@ 846 846 847 847 **DS18B20 and TMP117 Threshold Alarm** 848 848 849 - **~AT+WMOD=1,60,-10,20**847 + AT+WMOD=1,60,-10,20 850 850 851 851 (% style="color:#4f81bd" %)**Downlink Command:** 852 852 853 -**Example: 851 +**Example:**A5013CFC180014 854 854 855 855 MOD=01 856 856 ... ... @@ -863,11 +863,11 @@ 863 863 864 864 **Fluctuation alarm for DS18B20 and TMP117** 865 865 866 - **AT+WMOD=2,60,5**864 +AT+WMOD=2,60,5 867 867 868 868 (% style="color:#4f81bd" %)**Downlink Command:** 869 869 870 -**Example: 868 +**Example:**A5023C05 871 871 872 872 MOD=02 873 873 ... ... @@ -876,13 +876,13 @@ 876 876 temperature fluctuation=05 877 877 878 878 879 - ====**Samplingmultiple times anduplinktogether**====877 +**Collect multiple times and send once** 880 880 881 - **AT+WMOD=3,1,60,20,-16,32,1**~/~/879 +AT+WMOD=3,1,60,20,-16,32,1 ~/~/Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -10 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 882 882 883 883 (% style="color:#4f81bd" %)**Downlink Command:** 884 884 885 -**Example: 883 +**Example:**A50301003C14FFF0002001 886 886 887 887 MOD=03 888 888 ... ... @@ -898,27 +898,6 @@ 898 898 899 899 ARTEMP=01 900 900 901 - 902 -**Uplink payload( Fport=3)** 903 - 904 -**Example: **CBEA0109920A4109C4 905 - 906 -BatV=CBEA 907 - 908 -EXT=01 909 - 910 -Temp1=0992 ~/~/ 24.50℃ 911 - 912 -Temp2=0A41 ~/~/ 26.25℃ 913 - 914 -Temp3=09C4 ~/~/ 25.00℃ 915 - 916 - 917 -(% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 918 - 919 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 920 - 921 - 922 922 923 923 ))) 924 924 ... ... @@ -1337,7 +1337,7 @@ 1337 1337 1338 1338 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1339 1339 1340 -== 4.14 Modified W MOD command for external sensor TMP117 or DS18B20 temperature alarm(Sincefirmware 1.3.0)==1317 +== 4.14 Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm == 1341 1341 1342 1342 1343 1343 Feature: Set internal and external temperature sensor alarms.