Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 214.1
edited by Edwin Chen
on 2022/11/03 23:38
on 2022/11/03 23:38
Change comment:
There is no comment for this version
To version 218.1
edited by Bei Jinggeng
on 2022/11/16 15:24
on 2022/11/16 15:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -186,7 +186,6 @@ 186 186 187 187 188 188 189 - 190 190 === 2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. === 191 191 192 192 ... ... @@ -682,10 +682,8 @@ 682 682 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 683 683 ))) 684 684 685 -((( 686 - 687 -))) 688 688 685 + 689 689 ((( 690 690 **2. Manually Set Time** 691 691 ))) ... ... @@ -789,7 +789,7 @@ 789 789 790 790 791 791 792 -== 2.7 Alarm Mode == 789 +== 2.7 Alarm Mode & Feature "Multi sampling, one uplink" == 793 793 794 794 795 795 ((( ... ... @@ -883,9 +883,9 @@ 883 883 temperature fluctuation=05 884 884 885 885 886 -** Collectmultiple times andsendonce**883 +==== **Sampling multiple times and uplink together** ==== 887 887 888 -**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -1 0to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately.885 +**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -16 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 889 889 890 890 (% style="color:#4f81bd" %)**Downlink Command:** 891 891 ... ... @@ -924,16 +924,11 @@ 924 924 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 925 925 926 926 (% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 927 - 928 - 929 - 930 930 ))) 931 931 932 - (((926 + 933 933 === 2.7.2 ALARM MODE ( Before v1.3.1 firmware) === 934 934 935 - 936 -))) 937 937 938 938 (% _mstvisible="1" class="box infomessage" %) 939 939 ((( ... ... @@ -988,7 +988,6 @@ 988 988 * RED LED when external sensor is not connected 989 989 * For each success downlink, the PURPLE LED will blink once 990 990 991 - 992 992 == 2.9 installation == 993 993 994 994 ... ... @@ -1352,7 +1352,7 @@ 1352 1352 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1353 1353 1354 1354 1355 -== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm == 1346 +== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1356 1356 1357 1357 1358 1358 Feature: Set internal and external temperature sensor alarms. ... ... @@ -1397,6 +1397,8 @@ 1397 1397 1398 1398 0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 ) 1399 1399 1391 +0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Need to convert -16 to -1600 for calculation,-1600(DEC)=FFFFFFFFFFFFF9C0(HEX) FFFFFFFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX)) 1392 + 1400 1400 0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = second byte, third byte, fourth byte) 1401 1401 1402 1402 0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02. ... ... @@ -1409,22 +1409,17 @@ 1409 1409 == 5.1 Battery Type == 1410 1410 1411 1411 1405 + 1412 1412 ((( 1413 -((( 1414 1414 LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 1415 1415 ))) 1416 -))) 1417 1417 1418 -((( 1419 - 1420 -))) 1421 1421 1411 + 1422 1422 ((( 1423 -((( 1424 1424 The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1425 1425 [[image:image-20220515075034-1.png||_mstalt="428961" _mstvisible="4" height="208" width="644"]] 1426 1426 ))) 1427 -))) 1428 1428 1429 1429 The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 1430 1430 ... ... @@ -1447,9 +1447,6 @@ 1447 1447 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 1448 1448 ))) 1449 1449 1450 -((( 1451 - 1452 -))) 1453 1453 1454 1454 ((( 1455 1455 A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] ... ... @@ -1831,7 +1831,7 @@ 1831 1831 [[image:image-20220623113959-5.png||height="528" width="397"]] 1832 1832 1833 1833 (% _msthash="506146" _msttexthash="52173160" %) 1834 - Pressandholdthestartkeytoestartandenter(% _mstvisible="1" %)bootlaod(%%) mode.1819 +Connect A5 and GND with Dupont wire for a while and then separate 1835 1835 1836 1836 1837 1837