Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 214.1
edited by Edwin Chen
on 2022/11/03 23:38
on 2022/11/03 23:38
Change comment:
There is no comment for this version
To version 217.1
edited by Bei Jinggeng
on 2022/11/11 11:27
on 2022/11/11 11:27
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -61,7 +61,6 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 - 65 65 == 1.3 Specification == 66 66 67 67 ... ... @@ -86,7 +86,6 @@ 86 86 * ±2°C accuracy from -55°C to +125°C 87 87 * Operating Range: -55 °C ~~ 125 °C 88 88 89 - 90 90 = 2. Connect LHT65N to IoT Server = 91 91 92 92 ... ... @@ -245,7 +245,6 @@ 245 245 * The 7th byte (EXT #): defines the external sensor model. 246 246 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 247 247 248 - 249 249 === 2.4.1 Decoder in TTN V3 === 250 250 251 251 ... ... @@ -274,7 +274,6 @@ 274 274 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 275 275 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 276 276 277 - 278 278 === 2.4.3 Built-in Temperature === 279 279 280 280 ... ... @@ -286,7 +286,6 @@ 286 286 287 287 * Temperature: (0xF5C6-65536)/100=-26.18℃ 288 288 289 - 290 290 === 2.4.4 Built-in Humidity === 291 291 292 292 ... ... @@ -294,7 +294,6 @@ 294 294 295 295 * Humidity: 0x025C/10=60.4% 296 296 297 - 298 298 === 2.4.5 Ext # === 299 299 300 300 ... ... @@ -393,7 +393,6 @@ 393 393 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 394 394 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 395 395 396 - 397 397 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 398 398 399 399 ... ... @@ -789,7 +789,7 @@ 789 789 790 790 791 791 792 -== 2.7 Alarm Mode == 785 +== 2.7 Alarm Mode & Feature "Multi sampling, one uplink" == 793 793 794 794 795 795 ((( ... ... @@ -883,9 +883,9 @@ 883 883 temperature fluctuation=05 884 884 885 885 886 -** Collectmultiple times andsendonce**879 +==== **Sampling multiple times and uplink together** ==== 887 887 888 -**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -1 0to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately.881 +**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -16 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 889 889 890 890 (% style="color:#4f81bd" %)**Downlink Command:** 891 891 ... ... @@ -988,7 +988,6 @@ 988 988 * RED LED when external sensor is not connected 989 989 * For each success downlink, the PURPLE LED will blink once 990 990 991 - 992 992 == 2.9 installation == 993 993 994 994 ... ... @@ -1046,7 +1046,6 @@ 1046 1046 * Operating Range: -40 ~~ 125 °C 1047 1047 * Working voltage 2.35v ~~ 5v 1048 1048 1049 - 1050 1050 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1051 1051 1052 1052 ... ... @@ -1116,7 +1116,6 @@ 1116 1116 1117 1117 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1118 1118 1119 - 1120 1120 == 4.2 Set External Sensor Mode == 1121 1121 1122 1122 ... ... @@ -1140,7 +1140,6 @@ 1140 1140 1141 1141 * 0xA20702003c: Same as AT+SETCNT=60 1142 1142 1143 - 1144 1144 == 4.3 Enable/Disable uplink Temperature probe ID == 1145 1145 1146 1146 ... ... @@ -1171,7 +1171,6 @@ 1171 1171 * **0xA800** **~-~->** AT+PID=0 1172 1172 * **0xA801** **~-~->** AT+PID=1 1173 1173 1174 - 1175 1175 == 4.4 Set Password == 1176 1176 1177 1177 ... ... @@ -1223,7 +1223,6 @@ 1223 1223 1224 1224 * There is no downlink command to set to Sleep mode. 1225 1225 1226 - 1227 1227 == 4.7 Set system time == 1228 1228 1229 1229 ... ... @@ -1332,7 +1332,6 @@ 1332 1332 1333 1333 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1334 1334 1335 - 1336 1336 == 4.13 Auto Send None-ACK messages == 1337 1337 1338 1338 ... ... @@ -1351,10 +1351,9 @@ 1351 1351 1352 1352 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1353 1353 1340 +== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1354 1354 1355 -== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm == 1356 1356 1357 - 1358 1358 Feature: Set internal and external temperature sensor alarms. 1359 1359 1360 1360 (% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:500px" %) ... ... @@ -1397,6 +1397,8 @@ 1397 1397 1398 1398 0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 ) 1399 1399 1385 +0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Need to convert -16 to -1600 for calculation,-1600(DEC)=FFFFFFFFFFFFF9C0(HEX) FFFFFFFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX)) 1386 + 1400 1400 0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = second byte, third byte, fourth byte) 1401 1401 1402 1402 0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02. ... ... @@ -1872,7 +1872,6 @@ 1872 1872 1873 1873 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1874 1874 1875 - 1876 1876 = 8. Packing Info = 1877 1877 1878 1878 ... ... @@ -1886,13 +1886,11 @@ 1886 1886 * Device Size: 10 x 10 x 3.5 cm 1887 1887 * Device Weight: 120.5g 1888 1888 1889 - 1890 1890 = 9. Reference material = 1891 1891 1892 1892 1893 1893 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1894 1894 1895 - 1896 1896 = 10. FCC Warning = 1897 1897 1898 1898