Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 214.1
edited by Edwin Chen
on 2022/11/03 23:38
on 2022/11/03 23:38
Change comment:
There is no comment for this version
To version 211.1
edited by Bei Jinggeng
on 2022/11/01 16:33
on 2022/11/01 16:33
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -507,6 +507,7 @@ 507 507 508 508 509 509 510 + 510 510 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 511 511 512 512 ... ... @@ -626,7 +626,6 @@ 626 626 627 627 (% style="color:blue" %)**Method 2: **(%%)Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 628 628 629 - 630 630 (% style="color:red" %)**Note for method 2:** 631 631 632 632 * a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. ... ... @@ -804,12 +804,10 @@ 804 804 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 805 805 806 806 807 -**Internal GXHT30 temperature alarm** 808 - 809 809 ((( 810 810 (% class="box infomessage" %) 811 811 ((( 812 -**AT+WMOD=3**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 810 +**AT+WMOD=3,**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 813 813 814 814 **AT+CITEMP=1**: The interval between checking the alarm temperature. (In minutes) 815 815 ... ... @@ -823,109 +823,7 @@ 823 823 ))) 824 824 ))) 825 825 826 -(% style="color:#4f81bd" %)**Downlink Command:** 827 827 828 -AT+WMOD=1: A501 , AT+WMOD=0 : A600 829 - 830 -AT+CITEMP=1 : A60001 831 - 832 -AT+ARTEMP=1,60 : A70001003C 833 - 834 -AT+ARTEMP=-16,60 : A7FFF0003C 835 - 836 -AT+LEDALARM=1 : 3601 837 - 838 - 839 -(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 840 - 841 -Total bytes: 8 bytes 842 - 843 -**Example: **AA0100010001003C 844 - 845 -WMOD=01 846 - 847 -CITEMP=0001 848 - 849 -TEMPlow=0001 850 - 851 -TEMPhigh=003C 852 - 853 - 854 -**DS18B20 and TMP117 Threshold Alarm** 855 - 856 -**~ AT+WMOD=1,60,-10,20** 857 - 858 -(% style="color:#4f81bd" %)**Downlink Command:** 859 - 860 -**Example: **A5013CFC180014 861 - 862 -MOD=01 863 - 864 -CITEMP=3C(S) 865 - 866 -TEMPlow=FC18 867 - 868 -TEMPhigh=0014 869 - 870 - 871 -**Fluctuation alarm for DS18B20 and TMP117** 872 - 873 -**AT+WMOD=2,60,5** 874 - 875 -(% style="color:#4f81bd" %)**Downlink Command:** 876 - 877 -**Example: **A5023C05 878 - 879 -MOD=02 880 - 881 -CITEMP=3C(S) 882 - 883 -temperature fluctuation=05 884 - 885 - 886 -**Collect multiple times and send once** 887 - 888 -**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -10 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 889 - 890 -(% style="color:#4f81bd" %)**Downlink Command:** 891 - 892 -**Example: **A50301003C14FFF0002001 893 - 894 -MOD=03 895 - 896 -EXT=01 897 - 898 -CITEMP=003C(S) 899 - 900 -Total number of acquisitions=14 901 - 902 -TEMPlow=FFF0 903 - 904 -TEMPhigh=0020 905 - 906 -ARTEMP=01 907 - 908 - 909 -**Uplink payload( Fport=3)** 910 - 911 -**Example: **CBEA0109920A4109C4 912 - 913 -BatV=CBEA 914 - 915 -EXT=01 916 - 917 -Temp1=0992 ~/~/ 24.50℃ 918 - 919 -Temp2=0A41 ~/~/ 26.25℃ 920 - 921 -Temp3=09C4 ~/~/ 25.00℃ 922 - 923 - 924 -(% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 925 - 926 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 927 - 928 - 929 929 930 930 ))) 931 931 ... ... @@ -1352,7 +1352,7 @@ 1352 1352 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1353 1353 1354 1354 1355 -== 4.14 Modified W MOD command for external sensor TMP117 or DS18B20 temperature alarm ==1251 +== 4.14 Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm == 1356 1356 1357 1357 1358 1358 Feature: Set internal and external temperature sensor alarms.