Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 213.2
edited by Xiaoling
on 2022/11/02 15:39
on 2022/11/02 15:39
Change comment:
There is no comment for this version
To version 211.1
edited by Bei Jinggeng
on 2022/11/01 16:33
on 2022/11/01 16:33
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -62,7 +62,6 @@ 62 62 * Datalog feature (Max 3328 records) 63 63 64 64 65 - 66 66 == 1.3 Specification == 67 67 68 68 ... ... @@ -88,7 +88,6 @@ 88 88 * Operating Range: -55 °C ~~ 125 °C 89 89 90 90 91 - 92 92 = 2. Connect LHT65N to IoT Server = 93 93 94 94 ... ... @@ -248,7 +248,6 @@ 248 248 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 249 249 250 250 251 - 252 252 === 2.4.1 Decoder in TTN V3 === 253 253 254 254 ... ... @@ -278,7 +278,6 @@ 278 278 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 279 279 280 280 281 - 282 282 === 2.4.3 Built-in Temperature === 283 283 284 284 ... ... @@ -291,7 +291,6 @@ 291 291 * Temperature: (0xF5C6-65536)/100=-26.18℃ 292 292 293 293 294 - 295 295 === 2.4.4 Built-in Humidity === 296 296 297 297 ... ... @@ -300,7 +300,6 @@ 300 300 * Humidity: 0x025C/10=60.4% 301 301 302 302 303 - 304 304 === 2.4.5 Ext # === 305 305 306 306 ... ... @@ -400,7 +400,6 @@ 400 400 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 401 401 402 402 403 - 404 404 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 405 405 406 406 ... ... @@ -514,6 +514,7 @@ 514 514 515 515 516 516 510 + 517 517 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 518 518 519 519 ... ... @@ -633,7 +633,6 @@ 633 633 634 634 (% style="color:blue" %)**Method 2: **(%%)Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 635 635 636 - 637 637 (% style="color:red" %)**Note for method 2:** 638 638 639 639 * a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. ... ... @@ -811,12 +811,10 @@ 811 811 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 812 812 813 813 814 -**Internal GXHT30 temperature alarm** 815 - 816 816 ((( 817 817 (% class="box infomessage" %) 818 818 ((( 819 -**AT+WMOD=3**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 810 +**AT+WMOD=3,**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 820 820 821 821 **AT+CITEMP=1**: The interval between checking the alarm temperature. (In minutes) 822 822 ... ... @@ -830,109 +830,7 @@ 830 830 ))) 831 831 ))) 832 832 833 -(% style="color:#4f81bd" %)**Downlink Command:** 834 834 835 -AT+WMOD=1: A501 , AT+WMOD=0 : A600 836 - 837 -AT+CITEMP=1 : A60001 838 - 839 -AT+ARTEMP=1,60 : A70001003C 840 - 841 -AT+ARTEMP=-16,60 : A7FFF0003C 842 - 843 -AT+LEDALARM=1 : 3601 844 - 845 - 846 -(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 847 - 848 -Total bytes: 8 bytes 849 - 850 -**Example: **AA0100010001003C 851 - 852 -WMOD=01 853 - 854 -CITEMP=0001 855 - 856 -TEMPlow=0001 857 - 858 -TEMPhigh=003C 859 - 860 - 861 -**DS18B20 and TMP117 Threshold Alarm** 862 - 863 -**~ AT+WMOD=1,60,-10,20** 864 - 865 -(% style="color:#4f81bd" %)**Downlink Command:** 866 - 867 -**Example: **A5013CFC180014 868 - 869 -MOD=01 870 - 871 -CITEMP=3C(S) 872 - 873 -TEMPlow=FC18 874 - 875 -TEMPhigh=0014 876 - 877 - 878 -**Fluctuation alarm for DS18B20 and TMP117** 879 - 880 -**AT+WMOD=2,60,5** 881 - 882 -(% style="color:#4f81bd" %)**Downlink Command:** 883 - 884 -**Example: **A5023C05 885 - 886 -MOD=02 887 - 888 -CITEMP=3C(S) 889 - 890 -temperature fluctuation=05 891 - 892 - 893 -**Collect multiple times and send once** 894 - 895 -**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -10 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 896 - 897 -(% style="color:#4f81bd" %)**Downlink Command:** 898 - 899 -**Example: **A50301003C14FFF0002001 900 - 901 -MOD=03 902 - 903 -EXT=01 904 - 905 -CITEMP=003C(S) 906 - 907 -Total number of acquisitions=14 908 - 909 -TEMPlow=FFF0 910 - 911 -TEMPhigh=0020 912 - 913 -ARTEMP=01 914 - 915 - 916 -**Uplink payload( Fport=3)** 917 - 918 -**Example: **CBEA0109920A4109C4 919 - 920 -BatV=CBEA 921 - 922 -EXT=01 923 - 924 -Temp1=0992 ~/~/ 24.50℃ 925 - 926 -Temp2=0A41 ~/~/ 26.25℃ 927 - 928 -Temp3=09C4 ~/~/ 25.00℃ 929 - 930 - 931 -(% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 932 - 933 -(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 934 - 935 - 936 936 937 937 ))) 938 938 ... ... @@ -996,7 +996,6 @@ 996 996 * For each success downlink, the PURPLE LED will blink once 997 997 998 998 999 - 1000 1000 == 2.9 installation == 1001 1001 1002 1002 ... ... @@ -1055,7 +1055,6 @@ 1055 1055 * Working voltage 2.35v ~~ 5v 1056 1056 1057 1057 1058 - 1059 1059 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1060 1060 1061 1061 ... ... @@ -1126,7 +1126,6 @@ 1126 1126 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1127 1127 1128 1128 1129 - 1130 1130 == 4.2 Set External Sensor Mode == 1131 1131 1132 1132 ... ... @@ -1151,7 +1151,6 @@ 1151 1151 * 0xA20702003c: Same as AT+SETCNT=60 1152 1152 1153 1153 1154 - 1155 1155 == 4.3 Enable/Disable uplink Temperature probe ID == 1156 1156 1157 1157 ... ... @@ -1183,7 +1183,6 @@ 1183 1183 * **0xA801** **~-~->** AT+PID=1 1184 1184 1185 1185 1186 - 1187 1187 == 4.4 Set Password == 1188 1188 1189 1189 ... ... @@ -1236,7 +1236,6 @@ 1236 1236 * There is no downlink command to set to Sleep mode. 1237 1237 1238 1238 1239 - 1240 1240 == 4.7 Set system time == 1241 1241 1242 1242 ... ... @@ -1346,7 +1346,6 @@ 1346 1346 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1347 1347 1348 1348 1349 - 1350 1350 == 4.13 Auto Send None-ACK messages == 1351 1351 1352 1352 ... ... @@ -1366,7 +1366,6 @@ 1366 1366 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1367 1367 1368 1368 1369 - 1370 1370 == 4.14 Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm == 1371 1371 1372 1372 ... ... @@ -1888,7 +1888,6 @@ 1888 1888 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1889 1889 1890 1890 1891 - 1892 1892 = 8. Packing Info = 1893 1893 1894 1894 ... ... @@ -1903,7 +1903,6 @@ 1903 1903 * Device Weight: 120.5g 1904 1904 1905 1905 1906 - 1907 1907 = 9. Reference material = 1908 1908 1909 1909 ... ... @@ -1910,7 +1910,6 @@ 1910 1910 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1911 1911 1912 1912 1913 - 1914 1914 = 10. FCC Warning = 1915 1915 1916 1916