Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 213.1
edited by Bei Jinggeng
on 2022/11/02 11:17
on 2022/11/02 11:17
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -61,6 +61,8 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 + 65 + 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -85,6 +85,8 @@ 85 85 * ±2°C accuracy from -55°C to +125°C 86 86 * Operating Range: -55 °C ~~ 125 °C 87 87 90 + 91 + 88 88 = 2. Connect LHT65N to IoT Server = 89 89 90 90 ... ... @@ -184,7 +184,6 @@ 184 184 185 185 186 186 187 - 188 188 === 2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. === 189 189 190 190 ... ... @@ -243,6 +243,8 @@ 243 243 * The 7th byte (EXT #): defines the external sensor model. 244 244 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 245 245 249 + 250 + 246 246 === 2.4.1 Decoder in TTN V3 === 247 247 248 248 ... ... @@ -271,6 +271,8 @@ 271 271 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 272 272 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 273 273 279 + 280 + 274 274 === 2.4.3 Built-in Temperature === 275 275 276 276 ... ... @@ -282,6 +282,8 @@ 282 282 283 283 * Temperature: (0xF5C6-65536)/100=-26.18℃ 284 284 292 + 293 + 285 285 === 2.4.4 Built-in Humidity === 286 286 287 287 ... ... @@ -289,6 +289,8 @@ 289 289 290 290 * Humidity: 0x025C/10=60.4% 291 291 301 + 302 + 292 292 === 2.4.5 Ext # === 293 293 294 294 ... ... @@ -387,6 +387,8 @@ 387 387 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 388 388 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 389 389 401 + 402 + 390 390 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 391 391 392 392 ... ... @@ -500,7 +500,6 @@ 500 500 501 501 502 502 503 - 504 504 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 505 505 506 506 ... ... @@ -620,6 +620,7 @@ 620 620 621 621 (% style="color:blue" %)**Method 2: **(%%)Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 622 622 635 + 623 623 (% style="color:red" %)**Note for method 2:** 624 624 625 625 * a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. ... ... @@ -675,10 +675,8 @@ 675 675 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 676 676 ))) 677 677 678 -((( 679 - 680 -))) 681 681 692 + 682 682 ((( 683 683 **2. Manually Set Time** 684 684 ))) ... ... @@ -782,7 +782,7 @@ 782 782 783 783 784 784 785 -== 2.7 Alarm Mode == 796 +== 2.7 Alarm Mode & Feature "Multi sampling, one uplink" == 786 786 787 787 788 788 ((( ... ... @@ -796,6 +796,7 @@ 796 796 797 797 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 798 798 810 + 799 799 **Internal GXHT30 temperature alarm** 800 800 801 801 ((( ... ... @@ -827,11 +827,12 @@ 827 827 828 828 AT+LEDALARM=1 : 3601 829 829 842 + 830 830 (% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 831 831 832 832 Total bytes: 8 bytes 833 833 834 -**Example:**AA0100010001003C 847 +**Example: **AA0100010001003C 835 835 836 836 WMOD=01 837 837 ... ... @@ -844,11 +844,11 @@ 844 844 845 845 **DS18B20 and TMP117 Threshold Alarm** 846 846 847 - AT+WMOD=1,60,-10,20 860 +**~ AT+WMOD=1,60,-10,20** 848 848 849 849 (% style="color:#4f81bd" %)**Downlink Command:** 850 850 851 -**Example:**A5013CFC180014 864 +**Example: **A5013CFC180014 852 852 853 853 MOD=01 854 854 ... ... @@ -861,11 +861,11 @@ 861 861 862 862 **Fluctuation alarm for DS18B20 and TMP117** 863 863 864 -AT+WMOD=2,60,5 877 +**AT+WMOD=2,60,5** 865 865 866 866 (% style="color:#4f81bd" %)**Downlink Command:** 867 867 868 -**Example:**A5023C05 881 +**Example: **A5023C05 869 869 870 870 MOD=02 871 871 ... ... @@ -874,13 +874,13 @@ 874 874 temperature fluctuation=05 875 875 876 876 877 -** Collectmultiple times andsendonce**890 +==== **Sampling multiple times and uplink together** ==== 878 878 879 -AT+WMOD=3,1,60,20,-16,32,1 ~/~/Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -1 0to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately.892 +**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -16 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 880 880 881 881 (% style="color:#4f81bd" %)**Downlink Command:** 882 882 883 -**Example:**A50301003C14FFF0002001 896 +**Example: **A50301003C14FFF0002001 884 884 885 885 MOD=03 886 886 ... ... @@ -899,30 +899,27 @@ 899 899 900 900 **Uplink payload( Fport=3)** 901 901 902 -**Example:**CBEA0109920A4109C4 915 +**Example: **CBEA0109920A4109C4 903 903 904 904 BatV=CBEA 905 905 906 906 EXT=01 907 907 908 -Temp1=0992 ~/~/24.50℃ 921 +Temp1=0992 ~/~/ 24.50℃ 909 909 910 -Temp2=0A41 ~/~/26.25℃ 923 +Temp2=0A41 ~/~/ 26.25℃ 911 911 912 -Temp3=09C4 ~/~/25.00℃ 925 +Temp3=09C4 ~/~/ 25.00℃ 913 913 927 + 914 914 (% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 915 915 916 916 (% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 917 - 918 - 919 919 ))) 920 920 921 - (((933 + 922 922 === 2.7.2 ALARM MODE ( Before v1.3.1 firmware) === 923 923 924 - 925 -))) 926 926 927 927 (% _mstvisible="1" class="box infomessage" %) 928 928 ((( ... ... @@ -962,9 +962,7 @@ 962 962 TEMPhigh=003C 963 963 964 964 965 -=== === 966 966 967 - 968 968 == 2.8 LED Indicator == 969 969 970 970 ... ... @@ -979,6 +979,7 @@ 979 979 * RED LED when external sensor is not connected 980 980 * For each success downlink, the PURPLE LED will blink once 981 981 990 + 982 982 == 2.9 installation == 983 983 984 984 ... ... @@ -1036,6 +1036,8 @@ 1036 1036 * Operating Range: -40 ~~ 125 °C 1037 1037 * Working voltage 2.35v ~~ 5v 1038 1038 1048 + 1049 + 1039 1039 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1040 1040 1041 1041 ... ... @@ -1105,6 +1105,8 @@ 1105 1105 1106 1106 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1107 1107 1119 + 1120 + 1108 1108 == 4.2 Set External Sensor Mode == 1109 1109 1110 1110 ... ... @@ -1128,6 +1128,8 @@ 1128 1128 1129 1129 * 0xA20702003c: Same as AT+SETCNT=60 1130 1130 1144 + 1145 + 1131 1131 == 4.3 Enable/Disable uplink Temperature probe ID == 1132 1132 1133 1133 ... ... @@ -1158,6 +1158,8 @@ 1158 1158 * **0xA800** **~-~->** AT+PID=0 1159 1159 * **0xA801** **~-~->** AT+PID=1 1160 1160 1176 + 1177 + 1161 1161 == 4.4 Set Password == 1162 1162 1163 1163 ... ... @@ -1209,6 +1209,8 @@ 1209 1209 1210 1210 * There is no downlink command to set to Sleep mode. 1211 1211 1229 + 1230 + 1212 1212 == 4.7 Set system time == 1213 1213 1214 1214 ... ... @@ -1317,6 +1317,8 @@ 1317 1317 1318 1318 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1319 1319 1339 + 1340 + 1320 1320 == 4.13 Auto Send None-ACK messages == 1321 1321 1322 1322 ... ... @@ -1335,9 +1335,11 @@ 1335 1335 1336 1336 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1337 1337 1338 -== 4.14 Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm == 1339 1339 1340 1340 1361 +== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1362 + 1363 + 1341 1341 Feature: Set internal and external temperature sensor alarms. 1342 1342 1343 1343 (% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:500px" %) ... ... @@ -1380,6 +1380,8 @@ 1380 1380 1381 1381 0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 ) 1382 1382 1406 +0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Need to convert -16 to -1600 for calculation,-1600(DEC)=FFFFFFFFFFFFF9C0(HEX) FFFFFFFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX)) 1407 + 1383 1383 0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = second byte, third byte, fourth byte) 1384 1384 1385 1385 0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02. ... ... @@ -1392,22 +1392,17 @@ 1392 1392 == 5.1 Battery Type == 1393 1393 1394 1394 1420 + 1395 1395 ((( 1396 -((( 1397 1397 LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 1398 1398 ))) 1399 -))) 1400 1400 1401 -((( 1402 - 1403 -))) 1404 1404 1426 + 1405 1405 ((( 1406 -((( 1407 1407 The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1408 1408 [[image:image-20220515075034-1.png||_mstalt="428961" _mstvisible="4" height="208" width="644"]] 1409 1409 ))) 1410 -))) 1411 1411 1412 1412 The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 1413 1413 ... ... @@ -1430,9 +1430,6 @@ 1430 1430 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 1431 1431 ))) 1432 1432 1433 -((( 1434 - 1435 -))) 1436 1436 1437 1437 ((( 1438 1438 A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] ... ... @@ -1855,6 +1855,8 @@ 1855 1855 1856 1856 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1857 1857 1875 + 1876 + 1858 1858 = 8. Packing Info = 1859 1859 1860 1860 ... ... @@ -1868,11 +1868,15 @@ 1868 1868 * Device Size: 10 x 10 x 3.5 cm 1869 1869 * Device Weight: 120.5g 1870 1870 1890 + 1891 + 1871 1871 = 9. Reference material = 1872 1872 1873 1873 1874 1874 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1875 1875 1897 + 1898 + 1876 1876 = 10. FCC Warning = 1877 1877 1878 1878