... ... @@ -61,6 +61,8 @@
61 61  * Tri-color LED to indicate working status
62 62  * Datalog feature (Max 3328 records)
63 63  
64 +
65 +
64 64  == 1.3 Specification ==
65 65  
66 66  
... ... @@ -85,6 +85,8 @@
85 85  * ±2°C accuracy from -55°C to +125°C
86 86  * Operating Range: -55 °C ~~ 125 °C
87 87  
90 +
91 +
88 88  = 2. Connect LHT65N to IoT Server =
89 89  
90 90  
... ... @@ -184,7 +184,6 @@
184 184  
185 185  
186 186  
187 -
188 188  === 2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. ===
189 189  
190 190  
... ... @@ -243,6 +243,8 @@
243 243  * The 7th byte (EXT #): defines the external sensor model.
244 244  * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.)
245 245  
249 +
250 +
246 246  === 2.4.1 Decoder in TTN V3 ===
247 247  
248 248  
... ... @@ -271,6 +271,8 @@
271 271  * BAT status=(0Xcba4>>14)&0xFF=11(B),very good
272 272  * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
273 273  
279 +
280 +
274 274  === 2.4.3 Built-in Temperature ===
275 275  
276 276  
... ... @@ -282,6 +282,8 @@
282 282  
283 283  * Temperature:  (0xF5C6-65536)/100=-26.18℃
284 284  
292 +
293 +
285 285  === 2.4.4 Built-in Humidity ===
286 286  
287 287  
... ... @@ -289,6 +289,8 @@
289 289  
290 290  * Humidity:    0x025C/10=60.4%
291 291  
301 +
302 +
292 292  === 2.4.5 Ext # ===
293 293  
294 294  
... ... @@ -387,6 +387,8 @@
387 387  * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server.
388 388  * (% style="color:blue" %)**Unix Time Request**:(%%)  1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this)
389 389  
401 +
402 +
390 390  ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ====
391 391  
392 392  
... ... @@ -500,7 +500,6 @@
500 500  
501 501  
502 502  
503 -
504 504  ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ====
505 505  
506 506  
... ... @@ -620,6 +620,7 @@
620 620  
621 621  (% style="color:blue" %)**Method 2: **(%%)Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery.
622 622  
635 +
623 623  (% style="color:red" %)**Note for method 2:**
624 624  
625 625  * a) LHT65N will do an ACK check for data records sending to make sure every data arrive server.
... ... @@ -675,10 +675,8 @@
675 675  (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.**
676 676  )))
677 677  
678 -(((
679 -
680 -)))
681 681  
692 +
682 682  (((
683 683  **2. Manually Set Time**
684 684  )))
... ... @@ -782,7 +782,7 @@
782 782  
783 783  
784 784  
785 -== 2.7 Alarm Mode ==
796 +== 2.7 Alarm Mode & Feature "Multi sampling, one uplink" ==
786 786  
787 787  
788 788  (((
... ... @@ -796,6 +796,7 @@
796 796  
797 797  === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) ===
798 798  
810 +
799 799  **Internal GXHT30 temperature alarm**
800 800  
801 801  (((
... ... @@ -827,11 +827,12 @@
827 827  
828 828  AT+LEDALARM=1  :  3601
829 829  
842 +
830 830  (% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX**
831 831  
832 832  Total bytes: 8 bytes
833 833  
834 -**Example:**AA0100010001003C
847 +**Example: **AA0100010001003C
835 835  
836 836  WMOD=01
837 837  
... ... @@ -844,11 +844,11 @@
844 844  
845 845  **DS18B20 and TMP117 Threshold Alarm**
846 846  
847 - AT+WMOD=1,60,-10,20
860 +**~ AT+WMOD=1,60,-10,20**
848 848  
849 849  (% style="color:#4f81bd" %)**Downlink Command:**
850 850  
851 -**Example:**A5013CFC180014
864 +**Example: **A5013CFC180014
852 852  
853 853  MOD=01
854 854  
... ... @@ -861,11 +861,11 @@
861 861  
862 862  **Fluctuation alarm for DS18B20 and TMP117**
863 863  
864 -AT+WMOD=2,60,5
877 +**AT+WMOD=2,60,5** 
865 865  
866 866  (% style="color:#4f81bd" %)**Downlink Command:**
867 867  
868 -**Example:**A5023C05
881 +**Example: **A5023C05
869 869  
870 870  MOD=02
871 871  
... ... @@ -874,13 +874,13 @@
874 874  temperature fluctuation=05
875 875  
876 876  
877 -**Collect multiple times and send once**
890 +==== **Sampling multiple times and uplink together** ====
878 878  
879 -AT+WMOD=3,1,60,20,-16,32,1  ~/~/Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -10 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately.
892 +**AT+WMOD=3,1,60,20,-16,32,1**  ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -16 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately.
880 880  
881 881  (% style="color:#4f81bd" %)**Downlink Command:**
882 882  
883 -**Example:**A50301003C14FFF0002001
896 +**Example: **A50301003C14FFF0002001
884 884  
885 885  MOD=03
886 886  
... ... @@ -896,14 +896,30 @@
896 896  
897 897  ARTEMP=01
898 898  
899 -
912 +
913 +**Uplink payload( Fport=3)**
914 +
915 +**Example: **CBEA0109920A4109C4
916 +
917 +BatV=CBEA
918 +
919 +EXT=01
920 +
921 +Temp1=0992  ~/~/ 24.50℃
922 +
923 +Temp2=0A41  ~/~/ 26.25℃
924 +
925 +Temp3=09C4  ~/~/ 25.00℃
926 +
927 +
928 +(% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length**
929 +
930 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption**
900 900  )))
901 901  
902 -(((
933 +
903 903  === 2.7.2 ALARM MODE ( Before v1.3.1 firmware) ===
904 904  
905 -
906 -)))
907 907  
908 908  (% _mstvisible="1" class="box infomessage" %)
909 909  (((
... ... @@ -958,6 +958,7 @@
958 958  * RED LED when external sensor is not connected
959 959  * For each success downlink, the PURPLE LED will blink once
960 960  
990 +
961 961  == 2.9 installation ==
962 962  
963 963  
... ... @@ -1015,6 +1015,8 @@
1015 1015  * Operating Range: -40 ~~ 125 °C
1016 1016  * Working voltage 2.35v ~~ 5v
1017 1017  
1048 +
1049 +
1018 1018  = 4. Configure LHT65N via AT command or LoRaWAN downlink =
1019 1019  
1020 1020  
... ... @@ -1084,6 +1084,8 @@
1084 1084  
1085 1085  * **Example 2**: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
1086 1086  
1119 +
1120 +
1087 1087  == 4.2 Set External Sensor Mode ==
1088 1088  
1089 1089  
... ... @@ -1107,6 +1107,8 @@
1107 1107  
1108 1108  * 0xA20702003c: Same as AT+SETCNT=60
1109 1109  
1144 +
1145 +
1110 1110  == 4.3 Enable/Disable uplink Temperature probe ID ==
1111 1111  
1112 1112  
... ... @@ -1137,6 +1137,8 @@
1137 1137  * **0xA800**  **~-~->** AT+PID=0
1138 1138  * **0xA801**     **~-~->** AT+PID=1
1139 1139  
1176 +
1177 +
1140 1140  == 4.4 Set Password ==
1141 1141  
1142 1142  
... ... @@ -1188,6 +1188,8 @@
1188 1188  
1189 1189  * There is no downlink command to set to Sleep mode.
1190 1190  
1229 +
1230 +
1191 1191  == 4.7 Set system time ==
1192 1192  
1193 1193  
... ... @@ -1296,6 +1296,8 @@
1296 1296  
1297 1297  * Example: 0xA301  ~/~/  Same as AT+CLRDTA
1298 1298  
1339 +
1340 +
1299 1299  == 4.13 Auto Send None-ACK messages ==
1300 1300  
1301 1301  
... ... @@ -1314,9 +1314,11 @@
1314 1314  
1315 1315  * Example: 0x3401  ~/~/  Same as AT+PNACKMD=1
1316 1316  
1317 -== 4.14 Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm ==
1318 1318  
1319 1319  
1361 +== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) ==
1362 +
1363 +
1320 1320  Feature: Set internal and external temperature sensor alarms.
1321 1321  
1322 1322  (% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:500px" %)
... ... @@ -1359,6 +1359,8 @@
1359 1359  
1360 1360  0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105  (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 )
1361 1361  
1406 +0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Need to convert -16 to -1600 for calculation,-1600(DEC)=FFFFFFFFFFFFF9C0(HEX)  FFFFFFFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX))
1407 +
1362 1362  0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2  (AT+WMOD = second byte, third byte, fourth byte)
1363 1363  
1364 1364  0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02.
... ... @@ -1371,22 +1371,17 @@
1371 1371  == 5.1 Battery Type ==
1372 1372  
1373 1373  
1420 +
1374 1374  (((
1375 -(((
1376 1376  LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters.
1377 1377  )))
1378 -)))
1379 1379  
1380 -(((
1381 -
1382 -)))
1383 1383  
1426 +
1384 1384  (((
1385 -(((
1386 1386  The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance.
1387 1387  [[image:image-20220515075034-1.png||_mstalt="428961" _mstvisible="4" height="208" width="644"]]
1388 1388  )))
1389 -)))
1390 1390  
1391 1391  The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery.
1392 1392  
... ... @@ -1409,9 +1409,6 @@
1409 1409  [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]]
1410 1410  )))
1411 1411  
1412 -(((
1413 -
1414 -)))
1415 1415  
1416 1416  (((
1417 1417  A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]]
... ... @@ -1834,6 +1834,8 @@
1834 1834  
1835 1835  * (% style="color:red" %)**E3**(%%): External Temperature Probe
1836 1836  
1875 +
1876 +
1837 1837  = 8. Packing Info =
1838 1838  
1839 1839  
... ... @@ -1847,11 +1847,15 @@
1847 1847  * Device Size:  10 x 10 x 3.5 cm
1848 1848  * Device Weight: 120.5g
1849 1849  
1890 +
1891 +
1850 1850  = 9. Reference material =
1851 1851  
1852 1852  
1853 1853  * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]]
1854 1854  
1897 +
1898 +
1855 1855  = 10. FCC Warning =
1856 1856  
1857 1857