Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 212.1
edited by Bei Jinggeng
on 2022/11/01 17:55
on 2022/11/01 17:55
Change comment:
There is no comment for this version
To version 211.1
edited by Bei Jinggeng
on 2022/11/01 16:33
on 2022/11/01 16:33
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,6 +61,7 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 + 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -85,6 +85,7 @@ 85 85 * ±2°C accuracy from -55°C to +125°C 86 86 * Operating Range: -55 °C ~~ 125 °C 87 87 89 + 88 88 = 2. Connect LHT65N to IoT Server = 89 89 90 90 ... ... @@ -243,6 +243,7 @@ 243 243 * The 7th byte (EXT #): defines the external sensor model. 244 244 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 245 245 248 + 246 246 === 2.4.1 Decoder in TTN V3 === 247 247 248 248 ... ... @@ -271,6 +271,7 @@ 271 271 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 272 272 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 273 273 277 + 274 274 === 2.4.3 Built-in Temperature === 275 275 276 276 ... ... @@ -282,6 +282,7 @@ 282 282 283 283 * Temperature: (0xF5C6-65536)/100=-26.18℃ 284 284 289 + 285 285 === 2.4.4 Built-in Humidity === 286 286 287 287 ... ... @@ -289,6 +289,7 @@ 289 289 290 290 * Humidity: 0x025C/10=60.4% 291 291 297 + 292 292 === 2.4.5 Ext # === 293 293 294 294 ... ... @@ -387,6 +387,7 @@ 387 387 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 388 388 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 389 389 396 + 390 390 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 391 391 392 392 ... ... @@ -796,12 +796,11 @@ 796 796 797 797 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 798 798 799 -**Internal GXHT30 temperature alarm** 800 800 801 801 ((( 802 802 (% class="box infomessage" %) 803 803 ((( 804 -**AT+WMOD=3**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 810 +**AT+WMOD=3,**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 805 805 806 806 **AT+CITEMP=1**: The interval between checking the alarm temperature. (In minutes) 807 807 ... ... @@ -815,87 +815,7 @@ 815 815 ))) 816 816 ))) 817 817 818 -(% style="color:#4f81bd" %)**Downlink Command:** 819 819 820 -AT+WMOD=1: A501 , AT+WMOD=0 : A600 821 - 822 -AT+CITEMP=1 : A60001 823 - 824 -AT+ARTEMP=1,60 : A70001003C 825 - 826 -AT+ARTEMP=-16,60 : A7FFF0003C 827 - 828 -AT+LEDALARM=1 : 3601 829 - 830 -(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 831 - 832 -Total bytes: 8 bytes 833 - 834 -**Example:**AA0100010001003C 835 - 836 -WMOD=01 837 - 838 -CITEMP=0001 839 - 840 -TEMPlow=0001 841 - 842 -TEMPhigh=003C 843 - 844 - 845 -**DS18B20 and TMP117 Threshold Alarm** 846 - 847 - AT+WMOD=1,60,-10,20 848 - 849 -(% style="color:#4f81bd" %)**Downlink Command:** 850 - 851 -**Example:**A5013CFC180014 852 - 853 -MOD=01 854 - 855 -CITEMP=3C(S) 856 - 857 -TEMPlow=FC18 858 - 859 -TEMPhigh=0014 860 - 861 - 862 -**Fluctuation alarm for DS18B20 and TMP117** 863 - 864 -AT+WMOD=2,60,5 865 - 866 -(% style="color:#4f81bd" %)**Downlink Command:** 867 - 868 -**Example:**A5023C05 869 - 870 -MOD=02 871 - 872 -CITEMP=3C(S) 873 - 874 -temperature fluctuation=05 875 - 876 - 877 -**Collect multiple times and send once** 878 - 879 -AT+WMOD=3,1,60,20,-16,32,1 ~/~/Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -10 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 880 - 881 -(% style="color:#4f81bd" %)**Downlink Command:** 882 - 883 -**Example:**A50301003C14FFF0002001 884 - 885 -MOD=03 886 - 887 -EXT=01 888 - 889 -CITEMP=003C(S) 890 - 891 -Total number of acquisitions=14 892 - 893 -TEMPlow=FFF0 894 - 895 -TEMPhigh=0020 896 - 897 -ARTEMP=01 898 - 899 899 900 900 ))) 901 901 ... ... @@ -958,6 +958,7 @@ 958 958 * RED LED when external sensor is not connected 959 959 * For each success downlink, the PURPLE LED will blink once 960 960 887 + 961 961 == 2.9 installation == 962 962 963 963 ... ... @@ -1015,6 +1015,7 @@ 1015 1015 * Operating Range: -40 ~~ 125 °C 1016 1016 * Working voltage 2.35v ~~ 5v 1017 1017 945 + 1018 1018 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1019 1019 1020 1020 ... ... @@ -1084,6 +1084,7 @@ 1084 1084 1085 1085 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1086 1086 1015 + 1087 1087 == 4.2 Set External Sensor Mode == 1088 1088 1089 1089 ... ... @@ -1107,6 +1107,7 @@ 1107 1107 1108 1108 * 0xA20702003c: Same as AT+SETCNT=60 1109 1109 1039 + 1110 1110 == 4.3 Enable/Disable uplink Temperature probe ID == 1111 1111 1112 1112 ... ... @@ -1137,6 +1137,7 @@ 1137 1137 * **0xA800** **~-~->** AT+PID=0 1138 1138 * **0xA801** **~-~->** AT+PID=1 1139 1139 1070 + 1140 1140 == 4.4 Set Password == 1141 1141 1142 1142 ... ... @@ -1188,6 +1188,7 @@ 1188 1188 1189 1189 * There is no downlink command to set to Sleep mode. 1190 1190 1122 + 1191 1191 == 4.7 Set system time == 1192 1192 1193 1193 ... ... @@ -1296,6 +1296,7 @@ 1296 1296 1297 1297 * Example: 0xA301 ~/~/ Same as AT+CLRDTA 1298 1298 1231 + 1299 1299 == 4.13 Auto Send None-ACK messages == 1300 1300 1301 1301 ... ... @@ -1314,6 +1314,7 @@ 1314 1314 1315 1315 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1316 1316 1250 + 1317 1317 == 4.14 Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm == 1318 1318 1319 1319 ... ... @@ -1834,6 +1834,7 @@ 1834 1834 1835 1835 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1836 1836 1771 + 1837 1837 = 8. Packing Info = 1838 1838 1839 1839 ... ... @@ -1847,11 +1847,13 @@ 1847 1847 * Device Size: 10 x 10 x 3.5 cm 1848 1848 * Device Weight: 120.5g 1849 1849 1785 + 1850 1850 = 9. Reference material = 1851 1851 1852 1852 1853 1853 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1854 1854 1791 + 1855 1855 = 10. FCC Warning = 1856 1856 1857 1857