Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 211.1
edited by Bei Jinggeng
on 2022/11/01 16:33
on 2022/11/01 16:33
Change comment:
There is no comment for this version
To version 218.1
edited by Bei Jinggeng
on 2022/11/16 15:24
on 2022/11/16 15:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -186,7 +186,6 @@ 186 186 187 187 188 188 189 - 190 190 === 2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. === 191 191 192 192 ... ... @@ -507,7 +507,6 @@ 507 507 508 508 509 509 510 - 511 511 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 512 512 513 513 ... ... @@ -627,6 +627,7 @@ 627 627 628 628 (% style="color:blue" %)**Method 2: **(%%)Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 629 629 628 + 630 630 (% style="color:red" %)**Note for method 2:** 631 631 632 632 * a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. ... ... @@ -682,10 +682,8 @@ 682 682 (% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 683 683 ))) 684 684 685 -((( 686 - 687 -))) 688 688 685 + 689 689 ((( 690 690 **2. Manually Set Time** 691 691 ))) ... ... @@ -789,7 +789,7 @@ 789 789 790 790 791 791 792 -== 2.7 Alarm Mode == 789 +== 2.7 Alarm Mode & Feature "Multi sampling, one uplink" == 793 793 794 794 795 795 ((( ... ... @@ -804,10 +804,12 @@ 804 804 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 805 805 806 806 804 +**Internal GXHT30 temperature alarm** 805 + 807 807 ((( 808 808 (% class="box infomessage" %) 809 809 ((( 810 -**AT+WMOD=3 ,**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor)809 +**AT+WMOD=3**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 811 811 812 812 **AT+CITEMP=1**: The interval between checking the alarm temperature. (In minutes) 813 813 ... ... @@ -821,15 +821,112 @@ 821 821 ))) 822 822 ))) 823 823 823 +(% style="color:#4f81bd" %)**Downlink Command:** 824 824 825 - 825 +AT+WMOD=1: A501 , AT+WMOD=0 : A600 826 + 827 +AT+CITEMP=1 : A60001 828 + 829 +AT+ARTEMP=1,60 : A70001003C 830 + 831 +AT+ARTEMP=-16,60 : A7FFF0003C 832 + 833 +AT+LEDALARM=1 : 3601 834 + 835 + 836 +(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 837 + 838 +Total bytes: 8 bytes 839 + 840 +**Example: **AA0100010001003C 841 + 842 +WMOD=01 843 + 844 +CITEMP=0001 845 + 846 +TEMPlow=0001 847 + 848 +TEMPhigh=003C 849 + 850 + 851 +**DS18B20 and TMP117 Threshold Alarm** 852 + 853 +**~ AT+WMOD=1,60,-10,20** 854 + 855 +(% style="color:#4f81bd" %)**Downlink Command:** 856 + 857 +**Example: **A5013CFC180014 858 + 859 +MOD=01 860 + 861 +CITEMP=3C(S) 862 + 863 +TEMPlow=FC18 864 + 865 +TEMPhigh=0014 866 + 867 + 868 +**Fluctuation alarm for DS18B20 and TMP117** 869 + 870 +**AT+WMOD=2,60,5** 871 + 872 +(% style="color:#4f81bd" %)**Downlink Command:** 873 + 874 +**Example: **A5023C05 875 + 876 +MOD=02 877 + 878 +CITEMP=3C(S) 879 + 880 +temperature fluctuation=05 881 + 882 + 883 +==== **Sampling multiple times and uplink together** ==== 884 + 885 +**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -16 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 886 + 887 +(% style="color:#4f81bd" %)**Downlink Command:** 888 + 889 +**Example: **A50301003C14FFF0002001 890 + 891 +MOD=03 892 + 893 +EXT=01 894 + 895 +CITEMP=003C(S) 896 + 897 +Total number of acquisitions=14 898 + 899 +TEMPlow=FFF0 900 + 901 +TEMPhigh=0020 902 + 903 +ARTEMP=01 904 + 905 + 906 +**Uplink payload( Fport=3)** 907 + 908 +**Example: **CBEA0109920A4109C4 909 + 910 +BatV=CBEA 911 + 912 +EXT=01 913 + 914 +Temp1=0992 ~/~/ 24.50℃ 915 + 916 +Temp2=0A41 ~/~/ 26.25℃ 917 + 918 +Temp3=09C4 ~/~/ 25.00℃ 919 + 920 + 921 +(% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 922 + 923 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 826 826 ))) 827 827 828 - (((926 + 829 829 === 2.7.2 ALARM MODE ( Before v1.3.1 firmware) === 830 830 831 - 832 -))) 833 833 834 834 (% _mstvisible="1" class="box infomessage" %) 835 835 ((( ... ... @@ -884,7 +884,6 @@ 884 884 * RED LED when external sensor is not connected 885 885 * For each success downlink, the PURPLE LED will blink once 886 886 887 - 888 888 == 2.9 installation == 889 889 890 890 ... ... @@ -1248,7 +1248,7 @@ 1248 1248 * Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1249 1249 1250 1250 1251 -== 4.14 Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm ==1346 +== 4.14 Modified WMOD command for external sensor TMP117 or DS18B20 temperature alarm(Since firmware 1.3.0) == 1252 1252 1253 1253 1254 1254 Feature: Set internal and external temperature sensor alarms. ... ... @@ -1293,6 +1293,8 @@ 1293 1293 1294 1294 0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 ) 1295 1295 1391 +0XA5 01 0A F9 C0 29 04 ~-~-AT+WMOD=1,10,-16,105(Need to convert -16 to -1600 for calculation,-1600(DEC)=FFFFFFFFFFFFF9C0(HEX) FFFFFFFFFFFFF9C0(HEX) +10000(HEX)=F9C0(HEX)) 1392 + 1296 1296 0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = second byte, third byte, fourth byte) 1297 1297 1298 1298 0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02. ... ... @@ -1305,22 +1305,17 @@ 1305 1305 == 5.1 Battery Type == 1306 1306 1307 1307 1405 + 1308 1308 ((( 1309 -((( 1310 1310 LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. 1311 1311 ))) 1312 -))) 1313 1313 1314 -((( 1315 - 1316 -))) 1317 1317 1411 + 1318 1318 ((( 1319 -((( 1320 1320 The discharge curve is not linear so can't simply use percentage to show the battery level. Below is the battery performance. 1321 1321 [[image:image-20220515075034-1.png||_mstalt="428961" _mstvisible="4" height="208" width="644"]] 1322 1322 ))) 1323 -))) 1324 1324 1325 1325 The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 1326 1326 ... ... @@ -1343,9 +1343,6 @@ 1343 1343 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] 1344 1344 ))) 1345 1345 1346 -((( 1347 - 1348 -))) 1349 1349 1350 1350 ((( 1351 1351 A full detail test report for LHT65N on different frequency can be found at : [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0>>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]] ... ... @@ -1727,7 +1727,7 @@ 1727 1727 [[image:image-20220623113959-5.png||height="528" width="397"]] 1728 1728 1729 1729 (% _msthash="506146" _msttexthash="52173160" %) 1730 - Pressandholdthestartkeytoestartandenter(% _mstvisible="1" %)bootlaod(%%) mode.1819 +Connect A5 and GND with Dupont wire for a while and then separate 1731 1731 1732 1732 1733 1733