Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -375,7 +375,6 @@ 375 375 [[Unix Time Stamp>>||anchor="H2.6.2UnixTimeStamp"]] 376 376 ))) 377 377 378 - 379 379 * **Battery status & Built-in Humidity** 380 380 381 381 (% _mstvisible="1" border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:461px" %) ... ... @@ -390,7 +390,6 @@ 390 390 [[Built-in Humidity>>||anchor="H2.4.4Built-inHumidity"]] 391 391 ))) 392 392 393 - 394 394 * **Status & Ext Byte** 395 395 396 396 (% border="1" cellspacing="4" style="background-color:#ffffcc; color:green; width:500px" %) ... ... @@ -516,7 +516,6 @@ 516 516 517 517 518 518 519 - 520 520 ==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 521 521 522 522 ... ... @@ -636,6 +636,7 @@ 636 636 637 637 (% style="color:blue" %)**Method 2: **(%%)Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 638 638 636 + 639 639 (% style="color:red" %)**Note for method 2:** 640 640 641 641 * a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. ... ... @@ -736,7 +736,6 @@ 736 736 )))|=(% style="width: 90px;" %)**2**|=(% style="width: 90px;" %)**2**|=(% style="width: 70px;" %)**2**|=(% style="width: 100px;" %)**1**|=(% style="width: 70px;" %)**4** 737 737 |(% style="width:97px" %)**Value**|(% style="width:123px" %)[[External sensor data>>||anchor="H2.4.6Extvalue"]]|(% style="width:108px" %)[[Built In Temperature>>||anchor="H2.4.3Built-inTemperature"]]|(% style="width:133px" %)[[Built-in Humidity>>||anchor="H2.4.4Built-inHumidity"]]|(% style="width:159px" %)Poll message flag & Ext|(% style="width:80px" %)[[Unix Time Stamp>>||anchor="H2.6.2UnixTimeStamp"]] 738 738 739 - 740 740 **Poll message flag & Ext:** 741 741 742 742 [[image:image-20221006192726-1.png||height="112" width="754"]] ... ... @@ -749,7 +749,6 @@ 749 749 750 750 * Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands. 751 751 752 - 753 753 For example, in US915 band, the max payload for different DR is: 754 754 755 755 (% style="color:blue" %)**a) DR0:** (%%)max is 11 bytes so one entry of data ... ... @@ -815,10 +815,12 @@ 815 815 === 2.7.1 ALARM MODE ( Since v1.3.1 firmware) === 816 816 817 817 814 +**Internal GXHT30 temperature alarm** 815 + 818 818 ((( 819 819 (% class="box infomessage" %) 820 820 ((( 821 -**AT+WMOD=3 ,**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor)819 +**AT+WMOD=3**: Enable/disable alarm mode. (0: Disabled, 1: Enabled Temperature Alarm for onboard temperature sensor) 822 822 823 823 **AT+CITEMP=1**: The interval between checking the alarm temperature. (In minutes) 824 824 ... ... @@ -832,7 +832,109 @@ 832 832 ))) 833 833 ))) 834 834 833 +(% style="color:#4f81bd" %)**Downlink Command:** 835 835 835 +AT+WMOD=1: A501 , AT+WMOD=0 : A600 836 + 837 +AT+CITEMP=1 : A60001 838 + 839 +AT+ARTEMP=1,60 : A70001003C 840 + 841 +AT+ARTEMP=-16,60 : A7FFF0003C 842 + 843 +AT+LEDALARM=1 : 3601 844 + 845 + 846 +(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX** 847 + 848 +Total bytes: 8 bytes 849 + 850 +**Example: **AA0100010001003C 851 + 852 +WMOD=01 853 + 854 +CITEMP=0001 855 + 856 +TEMPlow=0001 857 + 858 +TEMPhigh=003C 859 + 860 + 861 +**DS18B20 and TMP117 Threshold Alarm** 862 + 863 +**~ AT+WMOD=1,60,-10,20** 864 + 865 +(% style="color:#4f81bd" %)**Downlink Command:** 866 + 867 +**Example: **A5013CFC180014 868 + 869 +MOD=01 870 + 871 +CITEMP=3C(S) 872 + 873 +TEMPlow=FC18 874 + 875 +TEMPhigh=0014 876 + 877 + 878 +**Fluctuation alarm for DS18B20 and TMP117** 879 + 880 +**AT+WMOD=2,60,5** 881 + 882 +(% style="color:#4f81bd" %)**Downlink Command:** 883 + 884 +**Example: **A5023C05 885 + 886 +MOD=02 887 + 888 +CITEMP=3C(S) 889 + 890 +temperature fluctuation=05 891 + 892 + 893 +**Collect multiple times and send once** 894 + 895 +**AT+WMOD=3,1,60,20,-16,32,1** ~/~/ Mode 3, the collection interval is 60s, the total number of collection is 20 times, and the data of these 20 times will be sent to the 20th time, with a maximum of 60 groups, the normal working temperature range is -10 to 32°C, 1 is to open the temperature alarm, 0 is to close the temperature alarm, and the temperature is turned on. After the alarm, if the temperature collected at the current time exceeds the normal working temperature, a data will be sent immediately. 896 + 897 +(% style="color:#4f81bd" %)**Downlink Command:** 898 + 899 +**Example: **A50301003C14FFF0002001 900 + 901 +MOD=03 902 + 903 +EXT=01 904 + 905 +CITEMP=003C(S) 906 + 907 +Total number of acquisitions=14 908 + 909 +TEMPlow=FFF0 910 + 911 +TEMPhigh=0020 912 + 913 +ARTEMP=01 914 + 915 + 916 +**Uplink payload( Fport=3)** 917 + 918 +**Example: **CBEA0109920A4109C4 919 + 920 +BatV=CBEA 921 + 922 +EXT=01 923 + 924 +Temp1=0992 ~/~/ 24.50℃ 925 + 926 +Temp2=0A41 ~/~/ 26.25℃ 927 + 928 +Temp3=09C4 ~/~/ 25.00℃ 929 + 930 + 931 +(% style="color:red" %)**Note: This uplink will automatically select the appropriate DR according to the data length** 932 + 933 +(% style="color:red" %)** In this mode, the temperature resolution of ds18b20 is 0.25℃ to save power consumption** 934 + 935 + 836 836 837 837 ))) 838 838