Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 205.1
edited by Edwin Chen
on 2022/10/11 18:16
on 2022/10/11 18:16
Change comment:
There is no comment for this version
To version 206.1
edited by Edwin Chen
on 2022/10/18 09:46
on 2022/10/18 09:46
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,6 +61,7 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 + 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -85,6 +85,7 @@ 85 85 * ±2°C accuracy from -55°C to +125°C 86 86 * Operating Range: -55 °C ~~ 125 °C 87 87 89 + 88 88 = 2. Connect LHT65N to IoT Server = 89 89 90 90 ... ... @@ -197,7 +197,7 @@ 197 197 198 198 199 199 200 -== 2.4 Uplink Payload == 202 +== 2.4 Uplink Payload ( Fport~=2) == 201 201 202 202 203 203 ((( ... ... @@ -276,17 +276,15 @@ 276 276 * The 7th byte (EXT #): defines the external sensor model. 277 277 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 278 278 281 + 279 279 === 2.4.1 Decoder in TTN V3 === 280 280 281 281 282 282 When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N decoder in TTNv3 for friendly reading. 283 283 284 -Below is the position to put the decoder and LHT65N decoder can be download from here: 287 +Below is the position to put the decoder and LHT65N decoder can be download from here: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 285 285 286 286 287 -[[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0 >>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0||_msthash="315253" _msttexthash="3509064" _mstvisible="2"]] 288 - 289 - 290 290 [[image:image-20220522234118-10.png||_mstalt="451464" _mstvisible="3" height="353" width="729"]] 291 291 292 292 ... ... @@ -308,6 +308,7 @@ 308 308 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 309 309 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 310 310 311 + 311 311 === 2.4.3 Built-in Temperature === 312 312 313 313 ... ... @@ -326,6 +326,7 @@ 326 326 327 327 * Humidity: 0x025C/10=60.4% 328 328 330 + 329 329 === 2.4.5 Ext # === 330 330 331 331 ... ... @@ -483,6 +483,8 @@ 483 483 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 484 484 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 485 485 488 + 489 + 486 486 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 487 487 488 488 ... ... @@ -997,9 +997,9 @@ 997 997 ((( 998 998 [[image:image-20221006192726-1.png||height="112" width="754"]] 999 999 1000 -(% class="mark" %)No ACK Message(%%): 1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]] feature) 1004 +(% class="mark" %)**No ACK Message**(%%): 1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]] feature) 1001 1001 1002 -(% class="mark" %)Poll Message Flag(%%): 1: This message is a poll message reply. 1006 +(% class="mark" %)**Poll Message Flag**(%%): 1: This message is a poll message reply. 1003 1003 1004 1004 1005 1005 ))) ... ... @@ -1050,7 +1050,7 @@ 1050 1050 ((( 1051 1051 (% _msthash="736725" _msttexthash="1065532" _mstvisible="3" %) 1052 1052 ((( 1053 -a) DR0: max is 11 bytes so one entry of data 1057 +**a) DR0:** max is 11 bytes so one entry of data 1054 1054 ))) 1055 1055 ))) 1056 1056 ))) ... ... @@ -1061,7 +1061,7 @@ 1061 1061 ((( 1062 1062 (% _msthash="736726" _msttexthash="3265665" _mstvisible="3" %) 1063 1063 ((( 1064 -b) DR1: max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 1068 +**b) DR1:** max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 1065 1065 ))) 1066 1066 ))) 1067 1067 ))) ... ... @@ -1072,7 +1072,7 @@ 1072 1072 ((( 1073 1073 (% _msthash="736727" _msttexthash="1454115" _mstvisible="3" style="text-align: left;" %) 1074 1074 ((( 1075 -c) DR2: total payload includes 11 entries of data 1079 +**c) DR2:** total payload includes 11 entries of data 1076 1076 ))) 1077 1077 ))) 1078 1078 ))) ... ... @@ -1083,7 +1083,7 @@ 1083 1083 ((( 1084 1084 (% _msthash="736728" _msttexthash="1483924" _mstvisible="3" style="text-align: left;" %) 1085 1085 ((( 1086 -d) DR3: total payload includes 22 entries of data. 1090 +**d) DR3: **total payload includes 22 entries of data. 1087 1087 ))) 1088 1088 ))) 1089 1089 ))) ... ... @@ -1094,7 +1094,7 @@ 1094 1094 ((( 1095 1095 (% _msthash="736729" _msttexthash="5848349" _mstvisible="3" style="text-align: left;" %) 1096 1096 ((( 1097 -If devise doesn ’t have any data in the polling time. Device will uplink 11 bytes of 01101 +If devise doesn't have any data in the polling time. Device will uplink 11 bytes of 0 1098 1098 ))) 1099 1099 ))) 1100 1100 ))) ... ... @@ -1255,6 +1255,7 @@ 1255 1255 * RED LED when external sensor is not connected 1256 1256 * For each success downlink, the PURPLE LED will blink once 1257 1257 1262 + 1258 1258 == 2.9 installation == 1259 1259 1260 1260 ... ... @@ -1312,6 +1312,7 @@ 1312 1312 * Operating Range: -40 ~~ 125 °C 1313 1313 * Working voltage 2.35v ~~ 5v 1314 1314 1320 + 1315 1315 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1316 1316 1317 1317 ... ... @@ -1381,6 +1381,7 @@ 1381 1381 1382 1382 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1383 1383 1390 + 1384 1384 == 4.2 Set External Sensor Mode == 1385 1385 1386 1386 ... ... @@ -1404,6 +1404,7 @@ 1404 1404 1405 1405 * 0xA20702003c: Same as AT+SETCNT=60 1406 1406 1414 + 1407 1407 == 4.3 Enable/Disable uplink Temperature probe ID == 1408 1408 1409 1409 ... ... @@ -1434,6 +1434,7 @@ 1434 1434 * **0xA800** **~-~->** AT+PID=0 1435 1435 * **0xA801** **~-~->** AT+PID=1 1436 1436 1445 + 1437 1437 == 4.4 Set Password == 1438 1438 1439 1439 ... ... @@ -1485,6 +1485,7 @@ 1485 1485 1486 1486 * There is no downlink command to set to Sleep mode. 1487 1487 1497 + 1488 1488 == 4.7 Set system time == 1489 1489 1490 1490 ... ... @@ -1540,7 +1540,7 @@ 1540 1540 1541 1541 (% _msthash="315257" _msttexthash="298038" style="color:#4f81bd" %)**Downlink Command:** 1542 1542 1543 -**0x29 0A** ~/~/ Same as AT+SYNCTDC=0x0A 1553 +**0x29 0A** ~/~/ Same as AT+SYNCTDC=0x0A 1544 1544 1545 1545 1546 1546 ... ... @@ -1591,8 +1591,9 @@ 1591 1591 1592 1592 (% style="color:#4f81bd" %)**Downlink Command: 0xA3** 1593 1593 1594 -* Example: 0xA301 ~/~/Same as AT+CLRDTA 1604 +* Example: 0xA301 ~/~/ Same as AT+CLRDTA 1595 1595 1606 + 1596 1596 == 4.13 Auto Send None-ACK messages == 1597 1597 1598 1598 ... ... @@ -1611,8 +1611,9 @@ 1611 1611 1612 1612 (% style="color:#4f81bd" %)**Downlink Command: 0x34** 1613 1613 1614 -* Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1625 +* Example: 0x3401 ~/~/ Same as AT+PNACKMD=1 1615 1615 1627 + 1616 1616 = 5. Battery & How to replace = 1617 1617 1618 1618