Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 205.1
edited by Edwin Chen
on 2022/10/11 18:16
on 2022/10/11 18:16
Change comment:
There is no comment for this version
To version 197.1
edited by Bei Jinggeng
on 2022/09/06 10:23
on 2022/09/06 10:23
Change comment:
Uploaded new attachment "image-20220906102307-7.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -16,7 +16,6 @@ 16 16 17 17 = 1. Introduction = 18 18 19 - 20 20 == 1.1 What is LHT65N Temperature & Humidity Sensor == 21 21 22 22 ... ... @@ -45,7 +45,6 @@ 45 45 ))) 46 46 47 47 48 - 49 49 == 1.2 Features == 50 50 51 51 ... ... @@ -61,10 +61,12 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 62 + 63 + 64 64 == 1.3 Specification == 65 65 66 66 67 - (% style="color:#037691" %)**Built-in Temperature Sensor:**67 +**Built-in Temperature Sensor:** 68 68 69 69 * Resolution: 0.01 °C 70 70 * Accuracy Tolerance : Typ ±0.3 °C ... ... @@ -71,7 +71,7 @@ 71 71 * Long Term Drift: < 0.02 °C/yr 72 72 * Operating Range: -40 ~~ 85 °C 73 73 74 - (% style="color:#037691" %)**Built-in Humidity Sensor:**74 +**Built-in Humidity Sensor:** 75 75 76 76 * Resolution: 0.04 %RH 77 77 * Accuracy Tolerance : Typ ±3 %RH ... ... @@ -78,7 +78,7 @@ 78 78 * Long Term Drift: < 0.02 °C/yr 79 79 * Operating Range: 0 ~~ 96 %RH 80 80 81 - (% style="color:#037691" %)**External Temperature Sensor:**81 +**External Temperature Sensor:** 82 82 83 83 * Resolution: 0.0625 °C 84 84 * ±0.5°C accuracy from -10°C to +85°C ... ... @@ -85,9 +85,10 @@ 85 85 * ±2°C accuracy from -55°C to +125°C 86 86 * Operating Range: -55 °C ~~ 125 °C 87 87 88 -= 2. Connect LHT65N to IoT Server = 89 89 90 90 90 += 2. Connect LHT65N to IoT Server = 91 + 91 91 == 2.1 How does LHT65N work? == 92 92 93 93 ... ... @@ -132,7 +132,6 @@ 132 132 (% _msthash="315240" _msttexthash="9205482" _mstvisible="1" class="wikigeneratedid" %) 133 133 This section shows an example of how to join the TTN V3 LoRaWAN IoT server. Use with other LoRaWAN IoT servers is of a similar procedure. 134 134 135 - 136 136 (% _mstvisible="1" class="wikigeneratedid" %) 137 137 [[image:image-20220522232442-1.png||_mstalt="427830" _mstvisible="3" height="387" width="648"]] 138 138 ... ... @@ -276,6 +276,8 @@ 276 276 * The 7th byte (EXT #): defines the external sensor model. 277 277 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 278 278 279 + 280 + 279 279 === 2.4.1 Decoder in TTN V3 === 280 280 281 281 ... ... @@ -308,6 +308,8 @@ 308 308 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 309 309 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 310 310 313 + 314 + 311 311 === 2.4.3 Built-in Temperature === 312 312 313 313 ... ... @@ -319,6 +319,8 @@ 319 319 320 320 * Temperature: (0xF5C6-65536)/100=-26.18℃ 321 321 326 + 327 + 322 322 === 2.4.4 Built-in Humidity === 323 323 324 324 ... ... @@ -326,6 +326,8 @@ 326 326 327 327 * Humidity: 0x025C/10=60.4% 328 328 335 + 336 + 329 329 === 2.4.5 Ext # === 330 330 331 331 ... ... @@ -483,6 +483,8 @@ 483 483 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 484 484 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 485 485 494 + 495 + 486 486 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 487 487 488 488 ... ... @@ -492,7 +492,7 @@ 492 492 493 493 sensor by setting: 494 494 495 -AT+EXT=6,timeout (% _msthash="506085" _msttexthash="8782189" _mstvisible="3" style="color:red" %) **Time to power this sensor, from 0 ~~ 65535ms**505 +AT+EXT=6,timeout (% _msthash="506085" _msttexthash="8782189" _mstvisible="3" style="color:red" %)Time to power this sensor, from 0 ~~ 65535ms 496 496 497 497 For example: 498 498 ... ... @@ -515,7 +515,6 @@ 515 515 516 516 When the voltage collected by ADC_IN1 is less than the minimum range, the minimum range will be used as the output; Similarly, when the collected voltage is greater than the maximum range, the maximum range will be used as the output. 517 517 518 - 519 519 1) The minimum range is about 0.1V. Each chip has internal calibration, so this value is close to 0.1V 520 520 521 521 [[image:image-20220628151005-5.png]] ... ... @@ -532,168 +532,6 @@ 532 532 533 533 534 534 535 -==== 2.4.6.4 Ext~=2 TMP117 Sensor (Since Firmware v1.3) ==== 536 - 537 - 538 -[[image:image-20220927095645-1.png||height="534" width="460"]] 539 - 540 - 541 -**Ext=2,Temperature Sensor(TMP117):** 542 - 543 -[[image:image-20220906102307-7.png]] 544 - 545 - 546 -(% style="color:blue" %)**Interrupt Mode and Counting Mode:** 547 - 548 -The external cable NE2 can be use for MOD4 and MOD8 549 - 550 - 551 - 552 - 553 -==== 2.4.6.5 Ext~=4 Interrupt Mode (Since Firmware v1.3) ==== 554 - 555 - 556 -(% style="color:red" %)**Note: In this mode, 3.3v output will be always ON. LHT65N will send an uplink when there is a trigger.** 557 - 558 - 559 -(% style="color:blue" %)**Interrupt Mode can be used to connect to external interrupt sensors such as:** 560 - 561 -**Case 1: Door Sensor.** 3.3v Out for such sensor is just to detect Open/Close. 562 - 563 - In Open State, the power consumption is the same as if there is no probe 564 - 565 - In Close state, the power consumption will be 3uA higher than normal. 566 - 567 -[[image:image-20220906100852-1.png||height="205" width="377"]] 568 - 569 - 570 -Ext=4,Interrupt Sensor: 571 - 572 -(% border="2" cellpadding="4" cellspacing="4" style="background-color:#ffffcc; color:green; height:6px; width:512px" %) 573 -|(% style="width:117px" %)((( 574 -AT+EXT=4,1 575 -)))|(% style="width:371px" %)((( 576 -Sent uplink packet in both rising and falling interrupt 577 -))) 578 -|(% style="width:117px" %)((( 579 -AT+EXT=4,2 580 -)))|(% style="width:371px" %)((( 581 -Sent uplink packet only in falling interrupt 582 -))) 583 -|(% style="width:117px" %)((( 584 -AT+EXT=4,3 585 -)))|(% style="width:371px" %)((( 586 -Sent uplink packet only in rising interrupt 587 -))) 588 - 589 -Trigger by falling edge: 590 - 591 -[[image:image-20220906101145-2.png]] 592 - 593 - 594 -Trigger by raising edge: 595 - 596 -[[image:image-20220906101145-3.png]] 597 - 598 - 599 - 600 - 601 -==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 602 - 603 - 604 -(% style="color:red" %)**Note: In this mode, 3.3v output will be always ON. LHT65N will count for every interrupt and uplink periodically.** 605 - 606 - 607 -(% style="color:blue" %)**Case 1**(%%): Low power consumption Flow Sensor, such flow sensor has pulse output and the power consumption in uA level and can be powered by LHT65N. 608 - 609 -[[image:image-20220906101320-4.png||height="366" width="698"]] 610 - 611 - 612 -(% style="color:blue" %)**Case 2**(%%): Normal Flow Sensor: Such flow sensor has higher power consumption and is not suitable to be powered by LHT65N. It is powered by external power and output <3.3v pulse 613 - 614 -[[image:image-20220906101320-5.png||height="353" width="696"]] 615 - 616 -Ext=8, Counting Sensor ( 4 bytes): 617 - 618 -(% border="2" cellpadding="4" cellspacing="4" style="background-color:#ffffcc; color:green; height:6px; width:381px" %) 619 -|(% style="width:138px" %)((( 620 -AT+EXT=8,0 621 -)))|(% style="width:240px" %)((( 622 -Count at falling interrupt 623 -))) 624 -|(% style="width:138px" %)((( 625 -AT+EXT=8,1 626 -)))|(% style="width:240px" %)((( 627 -Count at rising interrupt 628 -))) 629 -|(% style="width:138px" %)((( 630 -AT+SETCNT=60 631 -)))|(% style="width:240px" %)((( 632 -Sent current count to 60 633 -))) 634 - 635 -[[image:image-20220906101320-6.png]] 636 - 637 - 638 -(% style="color:blue" %)**A2 downlink Command:** 639 - 640 -A2 02: Same as AT+EXT=2 (AT+EXT= second byte) 641 - 642 -A2 06 01 F4: Same as AT+EXT=6,500 (AT+EXT= second byte, third and fourth bytes) 643 - 644 -A2 04 02: Same as AT+EXT=4,2 (AT+EXT= second byte, third byte) 645 - 646 -A2 08 01 00: Same as AT+EXT=8,0 (AT+EXT= second byte, fourth byte) 647 - 648 -A2 08 02 00 00 00 3C: Same as AT+ SETCNT=60 (AT+ SETCNT = 4th byte and 5th byte and 6th byte and 7th byte) 649 - 650 - 651 -(% style="color:blue" %)**Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm.** 652 - 653 - 654 -(% style="color:#037691" %)**AT+WMOD=parameter1,parameter2,parameter3,parameter4** 655 - 656 -(% style="color:#037691" %)**Parameter 1**(%%): Alarm mode: 657 - 658 -0): Cancel 659 - 660 -1): Threshold alarm 661 - 662 -2): Fluctuation alarm 663 - 664 - 665 -(% style="color:#037691" %)** Parameter 2**(%%): Sampling time. Unit: seconds, up to 255 seconds. 666 - 667 -(% style="color:red" %)**Note: When the collection time is less than 60 seconds and always exceeds the set alarm threshold, the sending interval will not be the collection time, but will be sent every 60 seconds.** 668 - 669 - 670 -(% style="color:#037691" %) **Parameter 3 and parameter 4:** 671 - 672 -1): If Alarm Mode is set to 1: Parameter 3 and parameter 4 are valid, as before, they represent low temperature and high temperature. 673 - 674 -Such as AT+WMOD=1,60,45,105, it means high and low temperature alarm. 675 - 676 - 677 -2): If Alarm Mode is set to 2: Parameter 3 is valid, which represents the difference between the currently collected temperature and the last uploaded temperature. 678 - 679 -Such as AT+WMOD=2,10,2,it means that it is a fluctuation alarm. 680 - 681 -If the difference between the current collected temperature and the last Uplin is ±2 degrees, the alarm will be issued. 682 - 683 - 684 -(% style="color:blue" %)** Downlink:** 685 - 686 -0xA5 00 ~-~- AT+WMOD=0. 687 - 688 -0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 ) 689 - 690 -0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = second byte, third byte, fourth byte) 691 - 692 -0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02. 693 - 694 - 695 - 696 - 697 697 == 2.5 Show data on Datacake == 698 698 699 699 ... ... @@ -756,19 +756,11 @@ 756 756 757 757 There are two methods: 758 758 759 -**Method 1**: IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specified time range. 606 +1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specifying time range. 607 +1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack message and store the sensor data, and it will send all messages (10s interval) after the network recovery. note: a) LHT65N will do ack check for data records sending to make sure every data arrive server. b) LHT65N will send data in CONFIRMED Mode when PNACKMD=1, but it won't re-transmit the same packet , it will just mark it as NONE-ACK and resend after network is detected. 760 760 761 - 762 -**Method 2: **Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 763 - 764 -**Note for method 2:** 765 - 766 -* a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. 767 -* b) LHT65N will send data in **CONFIRMED Mode** when PNACKMD=1, but LHT65N won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if LHT65N gets a ACK, LHT65N will consider there is a network connection and resend all NONE-ACK Message. 768 - 769 769 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 770 770 771 - 772 772 [[image:image-20220703111700-2.png||height="381" width="1119"]] 773 773 774 774 ... ... @@ -990,18 +990,15 @@ 990 990 (% _msthash="315268" _msttexthash="390390" _mstvisible="3" %)**Poll message flag & Ext** 991 991 992 992 (% _mstvisible="1" %) 832 +[[image:image-20220523152208-14.png||_mstalt="452920" _mstvisible="3"]] 833 + 834 +(% _mstvisible="1" %) 993 993 ((( 994 994 (% _mstvisible="2" %) 995 995 ((( 996 996 (% _msthash="736723" _msttexthash="2005003" _mstvisible="3" %) 997 997 ((( 998 -[[image:image-20221006192726-1.png||height="112" width="754"]] 999 - 1000 -(% class="mark" %)No ACK Message(%%): 1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]] feature) 1001 - 1002 -(% class="mark" %)Poll Message Flag(%%): 1: This message is a poll message reply. 1003 - 1004 - 840 +Poll Message Flag: 1: This message is a poll message reply. 1005 1005 ))) 1006 1006 ))) 1007 1007 ))) ... ... @@ -1142,7 +1142,6 @@ 1142 1142 (% _mstvisible="1" %) 1143 1143 [[image:image-20220523001219-13.png||_mstalt="451204" _mstvisible="3" height="421" style="text-align:left" width="727"]] 1144 1144 1145 - 1146 1146 (% _msthash="315271" _msttexthash="12012546" _mstvisible="1" style="text-align: left;" %) 1147 1147 ((( 1148 1148 7FFF089801464160065F977FFF088E014B41600660097FFF0885014E41600660667FFF0875015141600662BE7FFF086B015541600665167FFF08660155416006676E7FFF085F015A41600669C67FFF0857015D4160066C1E ... ... @@ -1255,6 +1255,8 @@ 1255 1255 * RED LED when external sensor is not connected 1256 1256 * For each success downlink, the PURPLE LED will blink once 1257 1257 1093 + 1094 + 1258 1258 == 2.9 installation == 1259 1259 1260 1260 ... ... @@ -1265,7 +1265,6 @@ 1265 1265 1266 1266 = 3. Sensors and Accessories = 1267 1267 1268 - 1269 1269 == 3.1 E2 Extension Cable == 1270 1270 1271 1271 ... ... @@ -1312,6 +1312,8 @@ 1312 1312 * Operating Range: -40 ~~ 125 °C 1313 1313 * Working voltage 2.35v ~~ 5v 1314 1314 1151 + 1152 + 1315 1315 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1316 1316 1317 1317 ... ... @@ -1381,6 +1381,8 @@ 1381 1381 1382 1382 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1383 1383 1222 + 1223 + 1384 1384 == 4.2 Set External Sensor Mode == 1385 1385 1386 1386 ... ... @@ -1404,6 +1404,8 @@ 1404 1404 1405 1405 * 0xA20702003c: Same as AT+SETCNT=60 1406 1406 1247 + 1248 + 1407 1407 == 4.3 Enable/Disable uplink Temperature probe ID == 1408 1408 1409 1409 ... ... @@ -1434,6 +1434,8 @@ 1434 1434 * **0xA800** **~-~->** AT+PID=0 1435 1435 * **0xA801** **~-~->** AT+PID=1 1436 1436 1279 + 1280 + 1437 1437 == 4.4 Set Password == 1438 1438 1439 1439 ... ... @@ -1485,6 +1485,8 @@ 1485 1485 1486 1486 * There is no downlink command to set to Sleep mode. 1487 1487 1332 + 1333 + 1488 1488 == 4.7 Set system time == 1489 1489 1490 1490 ... ... @@ -1498,7 +1498,7 @@ 1498 1498 1499 1499 (% _msthash="315254" _msttexthash="298038" style="color:#4f81bd" %)**Downlink Command:** 1500 1500 1501 -0x306007806000 1347 +0x306007806000 ~/~/ Set timestamp to 0x(6007806000),Same as AT+TIMESTAMP=1611104352 1502 1502 1503 1503 1504 1504 ... ... @@ -1522,8 +1522,8 @@ 1522 1522 1523 1523 (% style="color:#4f81bd" %)**Downlink Command:** 1524 1524 1525 -0x28 01 1526 -0x28 00 1371 +0x28 01 ~/~/ Same As AT+SYNCMOD=1 1372 +0x28 00 ~/~/ Same As AT+SYNCMOD=0 1527 1527 1528 1528 1529 1529 ... ... @@ -1593,6 +1593,8 @@ 1593 1593 1594 1594 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1595 1595 1442 + 1443 + 1596 1596 == 4.13 Auto Send None-ACK messages == 1597 1597 1598 1598 ... ... @@ -1613,9 +1613,10 @@ 1613 1613 1614 1614 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1615 1615 1616 -= 5. Battery & How to replace = 1617 1617 1618 1618 1466 += 5. Battery & How to replace = 1467 + 1619 1619 == 5.1 Battery Type == 1620 1620 1621 1621 ... ... @@ -1682,6 +1682,7 @@ 1682 1682 * (% style="background-color:yellow" %)**USB to TTL GND <~-~->GND** 1683 1683 * (% style="background-color:yellow" %)**USB to TTL RXD <~-~-> D+** 1684 1684 * (% style="background-color:yellow" %)**USB to TTL TXD <~-~-> A11** 1534 +* (% style="background-color:yellow" %)**USB to TTL 3.3V <~-~-> D-** 1685 1685 1686 1686 ((( 1687 1687 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. ... ... @@ -1933,7 +1933,7 @@ 1933 1933 == 6.3 How to change the uplink interval? == 1934 1934 1935 1935 1936 - Please see this link:[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_msthash="506137" _msttexthash="5712018"style="background-color: rgb(255, 255, 255);"]]1786 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_msthash="506137" _msttexthash="5712018"]] 1937 1937 1938 1938 1939 1939 ... ... @@ -1967,7 +1967,6 @@ 1967 1967 [[image:image-20220615170542-5.png]] 1968 1968 1969 1969 1970 - 1971 1971 (% style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 1972 1972 1973 1973 (% _msthash="506146" _msttexthash="52173160" %) ... ... @@ -1981,7 +1981,6 @@ 1981 1981 [[image:image-20220621170938-2.png]] 1982 1982 1983 1983 1984 - 1985 1985 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 1986 1986 1987 1987 [[image:image-20220615171334-6.png]] ... ... @@ -2030,7 +2030,6 @@ 2030 2030 [[image:image-20220615170542-5.png]] 2031 2031 2032 2032 2033 - 2034 2034 (% style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 2035 2035 2036 2036 (% _msthash="506146" _msttexthash="52173160" %) ... ... @@ -2043,7 +2043,6 @@ 2043 2043 Press and hold the start key to restart and enter (% _mstvisible="1" %)bootlaod(%%) mode. 2044 2044 2045 2045 2046 - 2047 2047 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 2048 2048 2049 2049 [[image:image-20220615171334-6.png]] ... ... @@ -2068,13 +2068,20 @@ 2068 2068 2069 2069 (% style="color:#4f81bd" %)**XX **(%%): The default frequency band 2070 2070 2071 -* (% style="color:#4f81bd" %)** **(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1917 +(% style="color:#4f81bd" %)** **(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1918 + 2072 2072 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1920 + 2073 2073 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1922 + 2074 2074 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1924 + 2075 2075 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1926 + 2076 2076 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1928 + 2077 2077 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1930 + 2078 2078 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 2079 2079 2080 2080 (% style="color:#4f81bd" %)**YY**(%%): Sensor Accessories ... ... @@ -2081,6 +2081,7 @@ 2081 2081 2082 2082 * (% style="color:red" %)**E3**(%%): External Temperature Probe 2083 2083 1937 + 2084 2084 = 8. Packing Info = 2085 2085 2086 2086 ... ... @@ -2094,11 +2094,13 @@ 2094 2094 * Device Size: 10 x 10 x 3.5 cm 2095 2095 * Device Weight: 120.5g 2096 2096 1951 + 2097 2097 = 9. Reference material = 2098 2098 2099 2099 2100 2100 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 2101 2101 1957 + 2102 2102 = 10. FCC Warning = 2103 2103 2104 2104 ... ... @@ -2107,6 +2107,3 @@ 2107 2107 (1) This device may not cause harmful interference; 2108 2108 2109 2109 (2) this device must accept any interference received, including interference that may cause undesired operation. 2110 - 2111 - 2112 -
- image-20220927095645-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -174.1 KB - Content
- image-20221006192726-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.3 KB - Content