Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 204.1
edited by Edwin Chen
on 2022/10/08 15:03
on 2022/10/08 15:03
Change comment:
There is no comment for this version
To version 203.1
edited by Edwin Chen
on 2022/10/06 19:30
on 2022/10/06 19:30
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,6 +61,7 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 + 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -85,6 +85,7 @@ 85 85 * ±2°C accuracy from -55°C to +125°C 86 86 * Operating Range: -55 °C ~~ 125 °C 87 87 89 + 88 88 = 2. Connect LHT65N to IoT Server = 89 89 90 90 ... ... @@ -277,6 +277,7 @@ 277 277 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 278 278 279 279 282 + 280 280 === 2.4.1 Decoder in TTN V3 === 281 281 282 282 ... ... @@ -310,6 +310,7 @@ 310 310 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 311 311 312 312 316 + 313 313 === 2.4.3 Built-in Temperature === 314 314 315 315 ... ... @@ -322,6 +322,7 @@ 322 322 * Temperature: (0xF5C6-65536)/100=-26.18℃ 323 323 324 324 329 + 325 325 === 2.4.4 Built-in Humidity === 326 326 327 327 ... ... @@ -330,6 +330,7 @@ 330 330 * Humidity: 0x025C/10=60.4% 331 331 332 332 338 + 333 333 === 2.4.5 Ext # === 334 334 335 335 ... ... @@ -488,6 +488,7 @@ 488 488 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 489 489 490 490 497 + 491 491 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 492 492 493 493 ... ... @@ -761,16 +761,9 @@ 761 761 762 762 There are two methods: 763 763 764 -**Method 1**: IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specified time range. 771 +1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specifying time range. 772 +1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack message and store the sensor data, and it will send all messages (10s interval) after the network recovery. note: a) LHT65N will do ack check for data records sending to make sure every data arrive server. b) LHT65N will send data in CONFIRMED Mode when PNACKMD=1, but it won't re-transmit the same packet , it will just mark it as NONE-ACK and resend after network is detected. 765 765 766 - 767 -**Method 2: **Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 768 - 769 -**Note for method 2:** 770 - 771 -* a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. 772 -* b) LHT65N will send data in **CONFIRMED Mode** when PNACKMD=1, but LHT65N won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if LHT65N gets a ACK, LHT65N will consider there is a network connection and resend all NONE-ACK Message. 773 - 774 774 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 775 775 776 776 ... ... @@ -1261,6 +1261,7 @@ 1261 1261 * For each success downlink, the PURPLE LED will blink once 1262 1262 1263 1263 1264 + 1264 1264 == 2.9 installation == 1265 1265 1266 1266 ... ... @@ -1319,6 +1319,7 @@ 1319 1319 * Working voltage 2.35v ~~ 5v 1320 1320 1321 1321 1323 + 1322 1322 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1323 1323 1324 1324 ... ... @@ -1389,6 +1389,7 @@ 1389 1389 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1390 1390 1391 1391 1394 + 1392 1392 == 4.2 Set External Sensor Mode == 1393 1393 1394 1394 ... ... @@ -1413,6 +1413,7 @@ 1413 1413 * 0xA20702003c: Same as AT+SETCNT=60 1414 1414 1415 1415 1419 + 1416 1416 == 4.3 Enable/Disable uplink Temperature probe ID == 1417 1417 1418 1418 ... ... @@ -1444,6 +1444,7 @@ 1444 1444 * **0xA801** **~-~->** AT+PID=1 1445 1445 1446 1446 1451 + 1447 1447 == 4.4 Set Password == 1448 1448 1449 1449 ... ... @@ -1496,6 +1496,7 @@ 1496 1496 * There is no downlink command to set to Sleep mode. 1497 1497 1498 1498 1504 + 1499 1499 == 4.7 Set system time == 1500 1500 1501 1501 ... ... @@ -1605,6 +1605,7 @@ 1605 1605 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1606 1606 1607 1607 1614 + 1608 1608 == 4.13 Auto Send None-ACK messages == 1609 1609 1610 1610 ... ... @@ -1626,6 +1626,7 @@ 1626 1626 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1627 1627 1628 1628 1636 + 1629 1629 = 5. Battery & How to replace = 1630 1630 1631 1631 ... ... @@ -2096,6 +2096,7 @@ 2096 2096 * (% style="color:red" %)**E3**(%%): External Temperature Probe 2097 2097 2098 2098 2107 + 2099 2099 = 8. Packing Info = 2100 2100 2101 2101 ... ... @@ -2110,6 +2110,7 @@ 2110 2110 * Device Weight: 120.5g 2111 2111 2112 2112 2122 + 2113 2113 = 9. Reference material = 2114 2114 2115 2115 ... ... @@ -2116,6 +2116,7 @@ 2116 2116 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 2117 2117 2118 2118 2129 + 2119 2119 = 10. FCC Warning = 2120 2120 2121 2121