Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 203.1
edited by Edwin Chen
on 2022/10/06 19:30
on 2022/10/06 19:30
Change comment:
There is no comment for this version
To version 205.1
edited by Edwin Chen
on 2022/10/11 18:16
on 2022/10/11 18:16
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,7 +61,6 @@ 61 61 * Tri-color LED to indicate working status 62 62 * Datalog feature (Max 3328 records) 63 63 64 - 65 65 == 1.3 Specification == 66 66 67 67 ... ... @@ -86,7 +86,6 @@ 86 86 * ±2°C accuracy from -55°C to +125°C 87 87 * Operating Range: -55 °C ~~ 125 °C 88 88 89 - 90 90 = 2. Connect LHT65N to IoT Server = 91 91 92 92 ... ... @@ -278,8 +278,6 @@ 278 278 * The 7th byte (EXT #): defines the external sensor model. 279 279 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 280 280 281 - 282 - 283 283 === 2.4.1 Decoder in TTN V3 === 284 284 285 285 ... ... @@ -312,8 +312,6 @@ 312 312 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 313 313 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 314 314 315 - 316 - 317 317 === 2.4.3 Built-in Temperature === 318 318 319 319 ... ... @@ -325,8 +325,6 @@ 325 325 326 326 * Temperature: (0xF5C6-65536)/100=-26.18℃ 327 327 328 - 329 - 330 330 === 2.4.4 Built-in Humidity === 331 331 332 332 ... ... @@ -334,8 +334,6 @@ 334 334 335 335 * Humidity: 0x025C/10=60.4% 336 336 337 - 338 - 339 339 === 2.4.5 Ext # === 340 340 341 341 ... ... @@ -493,8 +493,6 @@ 493 493 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 494 494 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 495 495 496 - 497 - 498 498 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 499 499 500 500 ... ... @@ -768,9 +768,16 @@ 768 768 769 769 There are two methods: 770 770 771 -1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specifying time range. 772 -1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack message and store the sensor data, and it will send all messages (10s interval) after the network recovery. note: a) LHT65N will do ack check for data records sending to make sure every data arrive server. b) LHT65N will send data in CONFIRMED Mode when PNACKMD=1, but it won't re-transmit the same packet , it will just mark it as NONE-ACK and resend after network is detected. 759 +**Method 1**: IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specified time range. 773 773 761 + 762 +**Method 2: **Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack messages and store the sensor data, and it will send all messages (10s interval) after the network recovery. 763 + 764 +**Note for method 2:** 765 + 766 +* a) LHT65N will do an ACK check for data records sending to make sure every data arrive server. 767 +* b) LHT65N will send data in **CONFIRMED Mode** when PNACKMD=1, but LHT65N won't re-transmit the packet if it doesn't get ACK, it will just mark it as a NONE-ACK message. In a future uplink if LHT65N gets a ACK, LHT65N will consider there is a network connection and resend all NONE-ACK Message. 768 + 774 774 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 775 775 776 776 ... ... @@ -1260,8 +1260,6 @@ 1260 1260 * RED LED when external sensor is not connected 1261 1261 * For each success downlink, the PURPLE LED will blink once 1262 1262 1263 - 1264 - 1265 1265 == 2.9 installation == 1266 1266 1267 1267 ... ... @@ -1319,8 +1319,6 @@ 1319 1319 * Operating Range: -40 ~~ 125 °C 1320 1320 * Working voltage 2.35v ~~ 5v 1321 1321 1322 - 1323 - 1324 1324 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1325 1325 1326 1326 ... ... @@ -1390,8 +1390,6 @@ 1390 1390 1391 1391 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1392 1392 1393 - 1394 - 1395 1395 == 4.2 Set External Sensor Mode == 1396 1396 1397 1397 ... ... @@ -1415,8 +1415,6 @@ 1415 1415 1416 1416 * 0xA20702003c: Same as AT+SETCNT=60 1417 1417 1418 - 1419 - 1420 1420 == 4.3 Enable/Disable uplink Temperature probe ID == 1421 1421 1422 1422 ... ... @@ -1447,8 +1447,6 @@ 1447 1447 * **0xA800** **~-~->** AT+PID=0 1448 1448 * **0xA801** **~-~->** AT+PID=1 1449 1449 1450 - 1451 - 1452 1452 == 4.4 Set Password == 1453 1453 1454 1454 ... ... @@ -1500,8 +1500,6 @@ 1500 1500 1501 1501 * There is no downlink command to set to Sleep mode. 1502 1502 1503 - 1504 - 1505 1505 == 4.7 Set system time == 1506 1506 1507 1507 ... ... @@ -1610,8 +1610,6 @@ 1610 1610 1611 1611 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1612 1612 1613 - 1614 - 1615 1615 == 4.13 Auto Send None-ACK messages == 1616 1616 1617 1617 ... ... @@ -1632,8 +1632,6 @@ 1632 1632 1633 1633 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1634 1634 1635 - 1636 - 1637 1637 = 5. Battery & How to replace = 1638 1638 1639 1639 ... ... @@ -1703,7 +1703,6 @@ 1703 1703 * (% style="background-color:yellow" %)**USB to TTL GND <~-~->GND** 1704 1704 * (% style="background-color:yellow" %)**USB to TTL RXD <~-~-> D+** 1705 1705 * (% style="background-color:yellow" %)**USB to TTL TXD <~-~-> A11** 1706 -* (% style="background-color:yellow" %)**USB to TTL 3.3V <~-~-> D-** 1707 1707 1708 1708 ((( 1709 1709 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**) (%%)to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. ... ... @@ -2103,8 +2103,6 @@ 2103 2103 2104 2104 * (% style="color:red" %)**E3**(%%): External Temperature Probe 2105 2105 2106 - 2107 - 2108 2108 = 8. Packing Info = 2109 2109 2110 2110 ... ... @@ -2118,15 +2118,11 @@ 2118 2118 * Device Size: 10 x 10 x 3.5 cm 2119 2119 * Device Weight: 120.5g 2120 2120 2121 - 2122 - 2123 2123 = 9. Reference material = 2124 2124 2125 2125 2126 2126 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 2127 2127 2128 - 2129 - 2130 2130 = 10. FCC Warning = 2131 2131 2132 2132