Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 203.1
edited by Edwin Chen
on 2022/10/06 19:30
on 2022/10/06 19:30
Change comment:
There is no comment for this version
To version 200.1
edited by Bei Jinggeng
on 2022/09/27 09:56
on 2022/09/27 09:56
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Bei - Content
-
... ... @@ -62,6 +62,7 @@ 62 62 * Datalog feature (Max 3328 records) 63 63 64 64 65 + 65 65 == 1.3 Specification == 66 66 67 67 ... ... @@ -87,6 +87,7 @@ 87 87 * Operating Range: -55 °C ~~ 125 °C 88 88 89 89 91 + 90 90 = 2. Connect LHT65N to IoT Server = 91 91 92 92 ... ... @@ -134,7 +134,6 @@ 134 134 (% _msthash="315240" _msttexthash="9205482" _mstvisible="1" class="wikigeneratedid" %) 135 135 This section shows an example of how to join the TTN V3 LoRaWAN IoT server. Use with other LoRaWAN IoT servers is of a similar procedure. 136 136 137 - 138 138 (% _mstvisible="1" class="wikigeneratedid" %) 139 139 [[image:image-20220522232442-1.png||_mstalt="427830" _mstvisible="3" height="387" width="648"]] 140 140 ... ... @@ -279,7 +279,6 @@ 279 279 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 280 280 281 281 282 - 283 283 === 2.4.1 Decoder in TTN V3 === 284 284 285 285 ... ... @@ -313,7 +313,6 @@ 313 313 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 314 314 315 315 316 - 317 317 === 2.4.3 Built-in Temperature === 318 318 319 319 ... ... @@ -326,7 +326,6 @@ 326 326 * Temperature: (0xF5C6-65536)/100=-26.18℃ 327 327 328 328 329 - 330 330 === 2.4.4 Built-in Humidity === 331 331 332 332 ... ... @@ -335,7 +335,6 @@ 335 335 * Humidity: 0x025C/10=60.4% 336 336 337 337 338 - 339 339 === 2.4.5 Ext # === 340 340 341 341 ... ... @@ -544,12 +544,10 @@ 544 544 545 545 546 546 547 -==== 2.4.6.4 Ext~=2 TMP117 Sensor ( SinceFirmwarev1.3) ====544 +==== 2.4.6.4 Ext~=2 TMP117 Sensor (since v1.3) ==== 548 548 549 - 550 550 [[image:image-20220927095645-1.png||height="534" width="460"]] 551 551 552 - 553 553 **Ext=2,Temperature Sensor(TMP117):** 554 554 555 555 [[image:image-20220906102307-7.png]] ... ... @@ -562,7 +562,7 @@ 562 562 563 563 564 564 565 -==== 2.4.6.5 Ext~=4 Interrupt Mode ( SinceFirmwarev1.3) ====560 +==== 2.4.6.5 Ext~=4 Interrupt Mode (since v1.3) ==== 566 566 567 567 568 568 (% style="color:red" %)**Note: In this mode, 3.3v output will be always ON. LHT65N will send an uplink when there is a trigger.** ... ... @@ -610,7 +610,7 @@ 610 610 611 611 612 612 613 -==== 2.4.6.6 Ext~=8 Counting Mode( SinceFirmwarev1.3) ====608 +==== 2.4.6.6 Ext~=8 Counting Mode(since v1.3) ==== 614 614 615 615 616 616 (% style="color:red" %)**Note: In this mode, 3.3v output will be always ON. LHT65N will count for every interrupt and uplink periodically.** ... ... @@ -773,7 +773,6 @@ 773 773 774 774 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 775 775 776 - 777 777 [[image:image-20220703111700-2.png||height="381" width="1119"]] 778 778 779 779 ... ... @@ -995,18 +995,15 @@ 995 995 (% _msthash="315268" _msttexthash="390390" _mstvisible="3" %)**Poll message flag & Ext** 996 996 997 997 (% _mstvisible="1" %) 992 +[[image:image-20220523152208-14.png||_mstalt="452920" _mstvisible="3"]] 993 + 994 +(% _mstvisible="1" %) 998 998 ((( 999 999 (% _mstvisible="2" %) 1000 1000 ((( 1001 1001 (% _msthash="736723" _msttexthash="2005003" _mstvisible="3" %) 1002 1002 ((( 1003 -[[image:image-20221006192726-1.png||height="112" width="754"]] 1004 - 1005 -(% class="mark" %)No ACK Message(%%): 1: This message means this payload is fromn Uplink Message which doesn't get ACK from the server before ( for [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]] feature) 1006 - 1007 -(% class="mark" %)Poll Message Flag(%%): 1: This message is a poll message reply. 1008 - 1009 - 1000 +Poll Message Flag: 1: This message is a poll message reply. 1010 1010 ))) 1011 1011 ))) 1012 1012 ))) ... ... @@ -1147,7 +1147,6 @@ 1147 1147 (% _mstvisible="1" %) 1148 1148 [[image:image-20220523001219-13.png||_mstalt="451204" _mstvisible="3" height="421" style="text-align:left" width="727"]] 1149 1149 1150 - 1151 1151 (% _msthash="315271" _msttexthash="12012546" _mstvisible="1" style="text-align: left;" %) 1152 1152 ((( 1153 1153 7FFF089801464160065F977FFF088E014B41600660097FFF0885014E41600660667FFF0875015141600662BE7FFF086B015541600665167FFF08660155416006676E7FFF085F015A41600669C67FFF0857015D4160066C1E ... ... @@ -1320,7 +1320,6 @@ 1320 1320 * Working voltage 2.35v ~~ 5v 1321 1321 1322 1322 1323 - 1324 1324 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1325 1325 1326 1326 ... ... @@ -1515,7 +1515,7 @@ 1515 1515 1516 1516 (% _msthash="315254" _msttexthash="298038" style="color:#4f81bd" %)**Downlink Command:** 1517 1517 1518 -0x306007806000 1507 +0x306007806000 ~/~/ Set timestamp to 0x(6007806000),Same as AT+TIMESTAMP=1611104352 1519 1519 1520 1520 1521 1521 ... ... @@ -1539,8 +1539,8 @@ 1539 1539 1540 1540 (% style="color:#4f81bd" %)**Downlink Command:** 1541 1541 1542 -0x28 01 1543 -0x28 00 1531 +0x28 01 ~/~/ Same As AT+SYNCMOD=1 1532 +0x28 00 ~/~/ Same As AT+SYNCMOD=0 1544 1544 1545 1545 1546 1546 ... ... @@ -1955,7 +1955,7 @@ 1955 1955 == 6.3 How to change the uplink interval? == 1956 1956 1957 1957 1958 - Please see this link:[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_msthash="506137" _msttexthash="5712018"style="background-color: rgb(255, 255, 255);"]]1947 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_msthash="506137" _msttexthash="5712018"]] 1959 1959 1960 1960 1961 1961 ... ... @@ -1989,7 +1989,6 @@ 1989 1989 [[image:image-20220615170542-5.png]] 1990 1990 1991 1991 1992 - 1993 1993 (% style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 1994 1994 1995 1995 (% _msthash="506146" _msttexthash="52173160" %) ... ... @@ -2003,7 +2003,6 @@ 2003 2003 [[image:image-20220621170938-2.png]] 2004 2004 2005 2005 2006 - 2007 2007 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 2008 2008 2009 2009 [[image:image-20220615171334-6.png]] ... ... @@ -2052,7 +2052,6 @@ 2052 2052 [[image:image-20220615170542-5.png]] 2053 2053 2054 2054 2055 - 2056 2056 (% style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 2057 2057 2058 2058 (% _msthash="506146" _msttexthash="52173160" %) ... ... @@ -2065,7 +2065,6 @@ 2065 2065 Press and hold the start key to restart and enter (% _mstvisible="1" %)bootlaod(%%) mode. 2066 2066 2067 2067 2068 - 2069 2069 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 2070 2070 2071 2071 [[image:image-20220615171334-6.png]]
- image-20221006192726-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.3 KB - Content