Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 202.1
edited by Edwin Chen
on 2022/10/06 19:27
on 2022/10/06 19:27
Change comment:
Uploaded new attachment "image-20221006192726-1.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 9 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -16,7 +16,6 @@ 16 16 17 17 = 1. Introduction = 18 18 19 - 20 20 == 1.1 What is LHT65N Temperature & Humidity Sensor == 21 21 22 22 ... ... @@ -45,7 +45,6 @@ 45 45 ))) 46 46 47 47 48 - 49 49 == 1.2 Features == 50 50 51 51 ... ... @@ -59,7 +59,7 @@ 59 59 * Built-in Temperature & Humidity sensor 60 60 * Optional External Sensors 61 61 * Tri-color LED to indicate working status 62 -* Datalog feature (Max 3328 records)60 +* Datalog feature 63 63 64 64 65 65 ... ... @@ -66,7 +66,7 @@ 66 66 == 1.3 Specification == 67 67 68 68 69 - (% style="color:#037691" %)**Built-in Temperature Sensor:**67 +**Built-in Temperature Sensor:** 70 70 71 71 * Resolution: 0.01 °C 72 72 * Accuracy Tolerance : Typ ±0.3 °C ... ... @@ -73,15 +73,19 @@ 73 73 * Long Term Drift: < 0.02 °C/yr 74 74 * Operating Range: -40 ~~ 85 °C 75 75 76 -(% style="color:#037691" %)**Built-in Humidity Sensor:** 77 77 75 + 76 +**Built-in Humidity Sensor:** 77 + 78 78 * Resolution: 0.04 %RH 79 79 * Accuracy Tolerance : Typ ±3 %RH 80 80 * Long Term Drift: < 0.02 °C/yr 81 81 * Operating Range: 0 ~~ 96 %RH 82 82 83 -(% style="color:#037691" %)**External Temperature Sensor:** 84 84 84 + 85 +**External Temperature Sensor:** 86 + 85 85 * Resolution: 0.0625 °C 86 86 * ±0.5°C accuracy from -10°C to +85°C 87 87 * ±2°C accuracy from -55°C to +125°C ... ... @@ -91,7 +91,6 @@ 91 91 92 92 = 2. Connect LHT65N to IoT Server = 93 93 94 - 95 95 == 2.1 How does LHT65N work? == 96 96 97 97 ... ... @@ -136,7 +136,6 @@ 136 136 (% _msthash="315240" _msttexthash="9205482" _mstvisible="1" class="wikigeneratedid" %) 137 137 This section shows an example of how to join the TTN V3 LoRaWAN IoT server. Use with other LoRaWAN IoT servers is of a similar procedure. 138 138 139 - 140 140 (% _mstvisible="1" class="wikigeneratedid" %) 141 141 [[image:image-20220522232442-1.png||_mstalt="427830" _mstvisible="3" height="387" width="648"]] 142 142 ... ... @@ -282,7 +282,6 @@ 282 282 283 283 284 284 285 - 286 286 === 2.4.1 Decoder in TTN V3 === 287 287 288 288 ... ... @@ -317,7 +317,6 @@ 317 317 318 318 319 319 320 - 321 321 === 2.4.3 Built-in Temperature === 322 322 323 323 ... ... @@ -331,7 +331,6 @@ 331 331 332 332 333 333 334 - 335 335 === 2.4.4 Built-in Humidity === 336 336 337 337 ... ... @@ -341,7 +341,6 @@ 341 341 342 342 343 343 344 - 345 345 === 2.4.5 Ext # === 346 346 347 347 ... ... @@ -353,7 +353,6 @@ 353 353 354 354 === 2.4.6 Ext value === 355 355 356 - 357 357 ==== 2.4.6.1 Ext~=1, E3 Temperature Sensor ==== 358 358 359 359 ... ... @@ -501,7 +501,6 @@ 501 501 502 502 503 503 504 - 505 505 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 506 506 507 507 ... ... @@ -511,7 +511,7 @@ 511 511 512 512 sensor by setting: 513 513 514 -AT+EXT=6,timeout (% _msthash="506085" _msttexthash="8782189" _mstvisible="3" style="color:red" %) **Time to power this sensor, from 0 ~~ 65535ms**508 +AT+EXT=6,timeout (% _msthash="506085" _msttexthash="8782189" _mstvisible="3" style="color:red" %)Time to power this sensor, from 0 ~~ 65535ms 515 515 516 516 For example: 517 517 ... ... @@ -534,7 +534,6 @@ 534 534 535 535 When the voltage collected by ADC_IN1 is less than the minimum range, the minimum range will be used as the output; Similarly, when the collected voltage is greater than the maximum range, the maximum range will be used as the output. 536 536 537 - 538 538 1) The minimum range is about 0.1V. Each chip has internal calibration, so this value is close to 0.1V 539 539 540 540 [[image:image-20220628151005-5.png]] ... ... @@ -551,168 +551,6 @@ 551 551 552 552 553 553 554 -==== 2.4.6.4 Ext~=2 TMP117 Sensor (Since Firmware v1.3) ==== 555 - 556 - 557 -[[image:image-20220927095645-1.png||height="534" width="460"]] 558 - 559 - 560 -**Ext=2,Temperature Sensor(TMP117):** 561 - 562 -[[image:image-20220906102307-7.png]] 563 - 564 - 565 -(% style="color:blue" %)**Interrupt Mode and Counting Mode:** 566 - 567 -The external cable NE2 can be use for MOD4 and MOD8 568 - 569 - 570 - 571 - 572 -==== 2.4.6.5 Ext~=4 Interrupt Mode (Since Firmware v1.3) ==== 573 - 574 - 575 -(% style="color:red" %)**Note: In this mode, 3.3v output will be always ON. LHT65N will send an uplink when there is a trigger.** 576 - 577 - 578 -(% style="color:blue" %)**Interrupt Mode can be used to connect to external interrupt sensors such as:** 579 - 580 -**Case 1: Door Sensor.** 3.3v Out for such sensor is just to detect Open/Close. 581 - 582 - In Open State, the power consumption is the same as if there is no probe 583 - 584 - In Close state, the power consumption will be 3uA higher than normal. 585 - 586 -[[image:image-20220906100852-1.png||height="205" width="377"]] 587 - 588 - 589 -Ext=4,Interrupt Sensor: 590 - 591 -(% border="2" cellpadding="4" cellspacing="4" style="background-color:#ffffcc; color:green; height:6px; width:512px" %) 592 -|(% style="width:117px" %)((( 593 -AT+EXT=4,1 594 -)))|(% style="width:371px" %)((( 595 -Sent uplink packet in both rising and falling interrupt 596 -))) 597 -|(% style="width:117px" %)((( 598 -AT+EXT=4,2 599 -)))|(% style="width:371px" %)((( 600 -Sent uplink packet only in falling interrupt 601 -))) 602 -|(% style="width:117px" %)((( 603 -AT+EXT=4,3 604 -)))|(% style="width:371px" %)((( 605 -Sent uplink packet only in rising interrupt 606 -))) 607 - 608 -Trigger by falling edge: 609 - 610 -[[image:image-20220906101145-2.png]] 611 - 612 - 613 -Trigger by raising edge: 614 - 615 -[[image:image-20220906101145-3.png]] 616 - 617 - 618 - 619 - 620 -==== 2.4.6.6 Ext~=8 Counting Mode(Since Firmware v1.3) ==== 621 - 622 - 623 -(% style="color:red" %)**Note: In this mode, 3.3v output will be always ON. LHT65N will count for every interrupt and uplink periodically.** 624 - 625 - 626 -(% style="color:blue" %)**Case 1**(%%): Low power consumption Flow Sensor, such flow sensor has pulse output and the power consumption in uA level and can be powered by LHT65N. 627 - 628 -[[image:image-20220906101320-4.png||height="366" width="698"]] 629 - 630 - 631 -(% style="color:blue" %)**Case 2**(%%): Normal Flow Sensor: Such flow sensor has higher power consumption and is not suitable to be powered by LHT65N. It is powered by external power and output <3.3v pulse 632 - 633 -[[image:image-20220906101320-5.png||height="353" width="696"]] 634 - 635 -Ext=8, Counting Sensor ( 4 bytes): 636 - 637 -(% border="2" cellpadding="4" cellspacing="4" style="background-color:#ffffcc; color:green; height:6px; width:381px" %) 638 -|(% style="width:138px" %)((( 639 -AT+EXT=8,0 640 -)))|(% style="width:240px" %)((( 641 -Count at falling interrupt 642 -))) 643 -|(% style="width:138px" %)((( 644 -AT+EXT=8,1 645 -)))|(% style="width:240px" %)((( 646 -Count at rising interrupt 647 -))) 648 -|(% style="width:138px" %)((( 649 -AT+SETCNT=60 650 -)))|(% style="width:240px" %)((( 651 -Sent current count to 60 652 -))) 653 - 654 -[[image:image-20220906101320-6.png]] 655 - 656 - 657 -(% style="color:blue" %)**A2 downlink Command:** 658 - 659 -A2 02: Same as AT+EXT=2 (AT+EXT= second byte) 660 - 661 -A2 06 01 F4: Same as AT+EXT=6,500 (AT+EXT= second byte, third and fourth bytes) 662 - 663 -A2 04 02: Same as AT+EXT=4,2 (AT+EXT= second byte, third byte) 664 - 665 -A2 08 01 00: Same as AT+EXT=8,0 (AT+EXT= second byte, fourth byte) 666 - 667 -A2 08 02 00 00 00 3C: Same as AT+ SETCNT=60 (AT+ SETCNT = 4th byte and 5th byte and 6th byte and 7th byte) 668 - 669 - 670 -(% style="color:blue" %)**Modified ATWOOD command for external sensor TMP117 or DS18B20 temperature alarm.** 671 - 672 - 673 -(% style="color:#037691" %)**AT+WMOD=parameter1,parameter2,parameter3,parameter4** 674 - 675 -(% style="color:#037691" %)**Parameter 1**(%%): Alarm mode: 676 - 677 -0): Cancel 678 - 679 -1): Threshold alarm 680 - 681 -2): Fluctuation alarm 682 - 683 - 684 -(% style="color:#037691" %)** Parameter 2**(%%): Sampling time. Unit: seconds, up to 255 seconds. 685 - 686 -(% style="color:red" %)**Note: When the collection time is less than 60 seconds and always exceeds the set alarm threshold, the sending interval will not be the collection time, but will be sent every 60 seconds.** 687 - 688 - 689 -(% style="color:#037691" %) **Parameter 3 and parameter 4:** 690 - 691 -1): If Alarm Mode is set to 1: Parameter 3 and parameter 4 are valid, as before, they represent low temperature and high temperature. 692 - 693 -Such as AT+WMOD=1,60,45,105, it means high and low temperature alarm. 694 - 695 - 696 -2): If Alarm Mode is set to 2: Parameter 3 is valid, which represents the difference between the currently collected temperature and the last uploaded temperature. 697 - 698 -Such as AT+WMOD=2,10,2,it means that it is a fluctuation alarm. 699 - 700 -If the difference between the current collected temperature and the last Uplin is ±2 degrees, the alarm will be issued. 701 - 702 - 703 -(% style="color:blue" %)** Downlink:** 704 - 705 -0xA5 00 ~-~- AT+WMOD=0. 706 - 707 -0xA5 01 0A 11 94 29 04 ~-~- AT+WMOD=1,10,45,105 (AT+WMOD = second byte, third byte, fourth and fifth bytes divided by 100, sixth and seventh bytes divided by 100 ) 708 - 709 -0xA5 02 0A 02 ~-~- AT+WMOD=2,10,2 (AT+WMOD = second byte, third byte, fourth byte) 710 - 711 -0xA5 FF ~-~- After the device receives it, upload the current alarm configuration (FPORT=8). Such as 01 0A 11 94 29 04 or 02 0A 02. 712 - 713 - 714 - 715 - 716 716 == 2.5 Show data on Datacake == 717 717 718 718 ... ... @@ -776,11 +776,10 @@ 776 776 There are two methods: 777 777 778 778 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specifying time range. 779 -1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will mark these records with non-ack message and store the sensor data, and it will send all messages(10s interval) after the network recovery.note: a) LHT65N will do ack check for data records sending to make sure every data arrive server. b) LHT65N will send data in CONFIRMED Mode when PNACKMD=1, but it won't re-transmit the same packet , it will just mark it as NONE-ACK and resend after network is detected.610 +1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after the network recovery. 780 780 781 781 Below is the typical case for the auto-update datalog feature (Set PNACKMD=1) 782 782 783 - 784 784 [[image:image-20220703111700-2.png||height="381" width="1119"]] 785 785 786 786 ... ... @@ -998,6 +998,7 @@ 998 998 ))) 999 999 ))) 1000 1000 831 + 1001 1001 (% _mstvisible="1" %) 1002 1002 (% _msthash="315268" _msttexthash="390390" _mstvisible="3" %)**Poll message flag & Ext** 1003 1003 ... ... @@ -1151,7 +1151,6 @@ 1151 1151 (% _mstvisible="1" %) 1152 1152 [[image:image-20220523001219-13.png||_mstalt="451204" _mstvisible="3" height="421" style="text-align:left" width="727"]] 1153 1153 1154 - 1155 1155 (% _msthash="315271" _msttexthash="12012546" _mstvisible="1" style="text-align: left;" %) 1156 1156 ((( 1157 1157 7FFF089801464160065F977FFF088E014B41600660097FFF0885014E41600660667FFF0875015141600662BE7FFF086B015541600665167FFF08660155416006676E7FFF085F015A41600669C67FFF0857015D4160066C1E ... ... @@ -1196,15 +1196,12 @@ 1196 1196 1197 1197 == 2.7 Alarm Mode == 1198 1198 1199 - 1200 1200 ((( 1201 1201 when the device is in alarm mode, it checks the built-in sensor temperature for a short time. if the temperature exceeds the preconfigured range, it sends an uplink immediately. 1202 1202 ))) 1203 1203 1204 1204 ((( 1205 -(% style="color:red" %)**Note: alarm mode adds a little power consumption, and we recommend extending the normal read time when this feature is enabled.** 1206 - 1207 - 1034 +(% style="color:red" %)Note: alarm mode adds a little power consumption, and we recommend extending the normal read time when this feature is enabled. 1208 1208 ))) 1209 1209 1210 1210 ((( ... ... @@ -1249,10 +1249,8 @@ 1249 1249 TEMPhigh=003C 1250 1250 1251 1251 1252 - 1253 1253 == 2.8 LED Indicator == 1254 1254 1255 - 1256 1256 The LHT65 has a triple color LED which for easy showing different stage . 1257 1257 1258 1258 While user press ACT button, the LED will work as per LED status with ACT button. ... ... @@ -1265,11 +1265,8 @@ 1265 1265 * For each success downlink, the PURPLE LED will blink once 1266 1266 1267 1267 1268 - 1269 - 1270 1270 == 2.9 installation == 1271 1271 1272 - 1273 1273 (% _mstvisible="1" %) 1274 1274 [[image:image-20220516231650-1.png||_mstalt="428597" _mstvisible="3" height="436" width="428"]] 1275 1275 ... ... @@ -1277,13 +1277,10 @@ 1277 1277 1278 1278 = 3. Sensors and Accessories = 1279 1279 1280 - 1281 1281 == 3.1 E2 Extension Cable == 1282 1282 1283 - 1284 1284 [[image:image-20220619092222-1.png||height="182" width="188"]][[image:image-20220619092313-2.png||height="182" width="173"]] 1285 1285 1286 - 1287 1287 **1m long breakout cable for LHT65N. Features:** 1288 1288 1289 1289 * ((( ... ... @@ -1300,9 +1300,6 @@ 1300 1300 ))) 1301 1301 * ((( 1302 1302 Exposed All pins from the LHT65N Type-C connector. 1303 - 1304 - 1305 - 1306 1306 ))) 1307 1307 1308 1308 [[image:image-20220619092421-3.png||height="371" width="529"]] ... ... @@ -1325,11 +1325,8 @@ 1325 1325 * Working voltage 2.35v ~~ 5v 1326 1326 1327 1327 1328 - 1329 - 1330 1330 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1331 1331 1332 - 1333 1333 ((( 1334 1334 Use can configure LHT65N via AT Command or LoRaWAN Downlink. 1335 1335 ))) ... ... @@ -1374,13 +1374,10 @@ 1374 1374 ))) 1375 1375 1376 1376 1377 - 1378 1378 == 4.1 Set Transmit Interval Time == 1379 1379 1380 - 1381 1381 Feature: Change LoRaWAN End Node Transmit Interval. 1382 1382 1383 - 1384 1384 (% style="color:#4f81bd" %)**AT Command: AT+TDC** 1385 1385 1386 1386 [[image:image-20220523150701-2.png||_mstalt="427453" _mstvisible="3"]] ... ... @@ -1397,14 +1397,10 @@ 1397 1397 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1398 1398 1399 1399 1400 - 1401 - 1402 1402 == 4.2 Set External Sensor Mode == 1403 1403 1404 - 1405 1405 Feature: Change External Sensor Mode. 1406 1406 1407 - 1408 1408 (% style="color:#4f81bd" %)**AT Command: AT+EXT** 1409 1409 1410 1410 [[image:image-20220523150759-3.png||_mstalt="432146" _mstvisible="3"]] ... ... @@ -1423,11 +1423,8 @@ 1423 1423 * 0xA20702003c: Same as AT+SETCNT=60 1424 1424 1425 1425 1426 - 1427 - 1428 1428 == 4.3 Enable/Disable uplink Temperature probe ID == 1429 1429 1430 - 1431 1431 ((( 1432 1432 Feature: If PID is enabled, device will send the temperature probe ID on: 1433 1433 ))) ... ... @@ -1441,8 +1441,6 @@ 1441 1441 1442 1442 ((( 1443 1443 PID is default set to disable (0) 1444 - 1445 - 1446 1446 ))) 1447 1447 1448 1448 (% style="color:#4f81bd" %)**AT Command:** ... ... @@ -1456,14 +1456,10 @@ 1456 1456 * **0xA801** **~-~->** AT+PID=1 1457 1457 1458 1458 1459 - 1460 - 1461 1461 == 4.4 Set Password == 1462 1462 1463 - 1464 1464 Feature: Set device password, max 9 digits 1465 1465 1466 - 1467 1467 (% style="color:#4f81bd" %)**AT Command: AT+PWORD** 1468 1468 1469 1469 [[image:image-20220523151052-5.png||_mstalt="428623" _mstvisible="3"]] ... ... @@ -1477,10 +1477,8 @@ 1477 1477 1478 1478 == 4.5 Quit AT Command == 1479 1479 1480 - 1481 1481 Feature: Quit AT Command mode, so user needs to input password again before use AT Commands. 1482 1482 1483 - 1484 1484 (% style="color:#4f81bd" %)**AT Command: AT+DISAT** 1485 1485 1486 1486 [[image:image-20220523151132-6.png||_mstalt="428649" _mstvisible="3"]] ... ... @@ -1494,7 +1494,6 @@ 1494 1494 1495 1495 == 4.6 Set to sleep mode == 1496 1496 1497 - 1498 1498 Feature: Set device to sleep mode 1499 1499 1500 1500 * **AT+Sleep=0** : Normal working mode, device will sleep and use lower power when there is no LoRa message ... ... @@ -1510,14 +1510,10 @@ 1510 1510 * There is no downlink command to set to Sleep mode. 1511 1511 1512 1512 1513 - 1514 - 1515 1515 == 4.7 Set system time == 1516 1516 1517 - 1518 1518 Feature: Set system time, unix format. [[See here for format detail.>>||anchor="H2.6.2UnixTimeStamp"]] 1519 1519 1520 - 1521 1521 (% _msthash="315253" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:** 1522 1522 1523 1523 [[image:image-20220523151253-8.png||_mstalt="430677" _mstvisible="3"]] ... ... @@ -1525,13 +1525,12 @@ 1525 1525 1526 1526 (% _msthash="315254" _msttexthash="298038" style="color:#4f81bd" %)**Downlink Command:** 1527 1527 1528 -0x306007806000 1318 +0x306007806000 ~/~/ Set timestamp to 0x(6007806000),Same as AT+TIMESTAMP=1611104352 1529 1529 1530 1530 1531 1531 1532 1532 == 4.8 Set Time Sync Mode == 1533 1533 1534 - 1535 1535 ((( 1536 1536 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command. 1537 1537 ))) ... ... @@ -1538,8 +1538,6 @@ 1538 1538 1539 1539 ((( 1540 1540 SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0. 1541 - 1542 - 1543 1543 ))) 1544 1544 1545 1545 (% _msthash="506058" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:** ... ... @@ -1549,17 +1549,15 @@ 1549 1549 1550 1550 (% style="color:#4f81bd" %)**Downlink Command:** 1551 1551 1552 -0x28 01 1553 -0x28 00 1339 +0x28 01 ~/~/ Same As AT+SYNCMOD=1 1340 +0x28 00 ~/~/ Same As AT+SYNCMOD=0 1554 1554 1555 1555 1556 1556 1557 1557 == 4.9 Set Time Sync Interval == 1558 1558 1559 - 1560 1560 Feature: Define System time sync interval. SYNCTDC default value: 10 days. 1561 1561 1562 - 1563 1563 (% _msthash="315256" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:** 1564 1564 1565 1565 [[image:image-20220523151411-10.png||_mstalt="449696" _mstvisible="3"]] ... ... @@ -1573,10 +1573,8 @@ 1573 1573 1574 1574 == 4.10 Print data entries base on page. == 1575 1575 1576 - 1577 1577 Feature: Print the sector data from start page to stop page (max is 416 pages). 1578 1578 1579 - 1580 1580 (% _msthash="315258" _msttexthash="264953" style="color:#4f81bd" %)**AT Command: AT+PDTA** 1581 1581 1582 1582 [[image:image-20220523151450-11.png||_mstalt="451035" _mstvisible="3"]] ... ... @@ -1590,10 +1590,8 @@ 1590 1590 1591 1591 == 4.11 Print last few data entries. == 1592 1592 1593 - 1594 1594 Feature: Print the last few data entries 1595 1595 1596 - 1597 1597 (% _msthash="315260" _msttexthash="288522" style="color:#4f81bd" %)**AT Command: AT+PLDTA** 1598 1598 1599 1599 [[image:image-20220523151524-12.png||_mstalt="452101" _mstvisible="3"]] ... ... @@ -1607,7 +1607,6 @@ 1607 1607 1608 1608 == 4.12 Clear Flash Record == 1609 1609 1610 - 1611 1611 Feature: Clear flash storage for data log feature. 1612 1612 1613 1613 ... ... @@ -1621,15 +1621,11 @@ 1621 1621 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1622 1622 1623 1623 1624 - 1625 - 1626 1626 == 4.13 Auto Send None-ACK messages == 1627 1627 1628 - 1629 1629 (% _msthash="315394" _msttexthash="51837149" _mstvisible="1" %) 1630 1630 Feature: LHT65N will wait for ACK for each uplink, If LHT65N doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. LHT65N keeps sending messages in normal periodically. Once LHT65N gets ACK from a server, it will consider the network is ok and start to send the not-arrive message. 1631 1631 1632 - 1633 1633 (% style="color:#4f81bd" %)**AT Command: AT+PNACKMD** 1634 1634 1635 1635 (% _msthash="315396" _msttexthash="734682" _mstvisible="1" %) ... ... @@ -1644,14 +1644,10 @@ 1644 1644 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1645 1645 1646 1646 1647 - 1648 - 1649 1649 = 5. Battery & How to replace = 1650 1650 1651 - 1652 1652 == 5.1 Battery Type == 1653 1653 1654 - 1655 1655 ((( 1656 1656 ((( 1657 1657 LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. ... ... @@ -1672,10 +1672,8 @@ 1672 1672 The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 1673 1673 1674 1674 1675 - 1676 1676 == 5.2 Replace Battery == 1677 1677 1678 - 1679 1679 LHT65N has two screws on the back, Unscrew them, and changing the battery inside is ok. The battery is a general CR17450 battery. Any brand should be ok. 1680 1680 1681 1681 [[image:image-20220515075440-2.png||_mstalt="429546" _mstvisible="3" height="338" width="272"]][[image:image-20220515075625-3.png||_mstalt="431574" _mstvisible="3" height="193" width="257"]] ... ... @@ -1683,7 +1683,6 @@ 1683 1683 1684 1684 == 5.3 Battery Life Analyze == 1685 1685 1686 - 1687 1687 ((( 1688 1688 Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life: 1689 1689 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] ... ... @@ -1701,10 +1701,8 @@ 1701 1701 1702 1702 = 6. FAQ = 1703 1703 1704 - 1705 1705 == 6.1 How to use AT Command? == 1706 1706 1707 - 1708 1708 LHT65N supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 1709 1709 1710 1710 [[image:image-20220530085651-1.png||_mstalt="429949"]] ... ... @@ -1923,43 +1923,40 @@ 1923 1923 AT+PID: Get or set the PID 1924 1924 1925 1925 1926 - 1927 1927 == 6.2 Where to use AT commands and Downlink commands == 1928 1928 1695 +(% _msthash="506131" _msttexthash="14585714" %) 1696 +AT commands: 1929 1929 1930 -**AT commands:** 1931 - 1932 1932 [[image:image-20220620153708-1.png||height="603" width="723"]] 1933 1933 1700 +(% _msthash="506132" _msttexthash="337922" %) 1701 +Downlink commands: 1934 1934 1935 -**Downlink commands:** 1936 1936 1704 +(% _msthash="506133" _msttexthash="33046" %) 1705 +**TTN:** 1937 1937 1938 - 1939 -(% style="color:blue" %)**TTN:** 1940 - 1941 1941 [[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 1942 1942 1943 1943 1710 +(% _msthash="506134" _msttexthash="11113791" %) 1711 +**Helium:** 1944 1944 1945 -(% style="color:blue" %)**Helium:** 1946 - 1947 1947 [[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 1948 1948 1949 1949 1716 +(% _msthash="506135" _msttexthash="4159844" %) 1717 +**Chirpstack:The downlink window will not be displayed until the network is accessed** 1950 1950 1951 -(% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed** 1952 - 1953 - 1954 1954 [[image:image-20220615094850-6.png||_mstalt="433082"]] 1955 1955 1956 - 1957 1957 [[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 1958 1958 1959 1959 1724 +(% _msthash="506136" _msttexthash="39286" %) 1725 +**Aws:** 1960 1960 1961 -(% style="color:blue" %)**Aws:** 1962 - 1963 1963 [[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 1964 1964 1965 1965 ... ... @@ -1966,14 +1966,12 @@ 1966 1966 1967 1967 == 6.3 How to change the uplink interval? == 1968 1968 1733 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_msthash="506137" _msttexthash="5712018"]] 1969 1969 1970 -Please see this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_msthash="506137" _msttexthash="5712018" style="background-color: rgb(255, 255, 255);"]] 1971 1971 1972 1972 1973 - 1974 1974 == 6.4 How to use TTL-USB to connect a PC to input AT commands? == 1975 1975 1976 - 1977 1977 [[image:image-20220615153355-1.png]] 1978 1978 1979 1979 [[image:1655802313617-381.png]] ... ... @@ -2001,7 +2001,6 @@ 2001 2001 [[image:image-20220615170542-5.png]] 2002 2002 2003 2003 2004 - 2005 2005 (% style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 2006 2006 2007 2007 (% _msthash="506146" _msttexthash="52173160" %) ... ... @@ -2015,7 +2015,6 @@ 2015 2015 [[image:image-20220621170938-2.png]] 2016 2016 2017 2017 2018 - 2019 2019 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 2020 2020 2021 2021 [[image:image-20220615171334-6.png]] ... ... @@ -2032,16 +2032,13 @@ 2032 2032 Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. 2033 2033 2034 2034 2035 - 2036 2036 == 6.6 Using USB-TYPE-C to connect to the computer using the AT command == 2037 2037 2038 - 2039 2039 [[image:image-20220623110706-1.png]] 2040 2040 2041 2041 2042 2042 [[image:image-20220623112117-4.png||height="459" width="343"]] 2043 2043 2044 - 2045 2045 ((( 2046 2046 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 2047 2047 ))) ... ... @@ -2052,19 +2052,15 @@ 2052 2052 [[image:image-20220615154519-3.png||height="672" width="807"]] 2053 2053 2054 2054 2055 - 2056 2056 == 6.7 How to use USB-TYPE-C to connect PC to upgrade firmware? == 2057 2057 2058 - 2059 2059 [[image:image-20220623110706-1.png]] 2060 2060 2061 - 2062 2062 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 2063 2063 2064 2064 [[image:image-20220615170542-5.png]] 2065 2065 2066 2066 2067 - 2068 2068 (% style="color:blue" %)**Step2**(%%):wiring method.(% style="display:none" %) 2069 2069 2070 2070 (% _msthash="506146" _msttexthash="52173160" %) ... ... @@ -2076,8 +2076,6 @@ 2076 2076 (% _msthash="506146" _msttexthash="52173160" %) 2077 2077 Press and hold the start key to restart and enter (% _mstvisible="1" %)bootlaod(%%) mode. 2078 2078 2079 - 2080 - 2081 2081 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 2082 2082 2083 2083 [[image:image-20220615171334-6.png]] ... ... @@ -2094,7 +2094,6 @@ 2094 2094 Finally,restart reset device again 2095 2095 2096 2096 2097 - 2098 2098 = 7. Order Info = 2099 2099 2100 2100 ... ... @@ -2102,13 +2102,20 @@ 2102 2102 2103 2103 (% style="color:#4f81bd" %)**XX **(%%): The default frequency band 2104 2104 2105 -* (% style="color:#4f81bd" %)** **(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1855 +(% style="color:#4f81bd" %)** **(% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1856 + 2106 2106 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1858 + 2107 2107 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1860 + 2108 2108 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1862 + 2109 2109 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1864 + 2110 2110 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1866 + 2111 2111 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1868 + 2112 2112 * (% style="color:#4f81bd" %)** **(% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 2113 2113 2114 2114 (% style="color:#4f81bd" %)**YY**(%%): Sensor Accessories ... ... @@ -2116,8 +2116,6 @@ 2116 2116 * (% style="color:red" %)**E3**(%%): External Temperature Probe 2117 2117 2118 2118 2119 - 2120 - 2121 2121 = 8. Packing Info = 2122 2122 2123 2123 ... ... @@ -2132,24 +2132,15 @@ 2132 2132 * Device Weight: 120.5g 2133 2133 2134 2134 2135 - 2136 - 2137 2137 = 9. Reference material = 2138 2138 2139 - 2140 2140 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 2141 2141 2142 2142 2143 - 2144 - 2145 2145 = 10. FCC Warning = 2146 2146 2147 - 2148 2148 This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: 2149 2149 2150 2150 (1) This device may not cause harmful interference; 2151 2151 2152 2152 (2) this device must accept any interference received, including interference that may cause undesired operation. 2153 - 2154 - 2155 -
- image-20220906100852-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -251.9 KB - Content
- image-20220906101145-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.3 KB - Content
- image-20220906101145-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.6 KB - Content
- image-20220906101320-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -202.3 KB - Content
- image-20220906101320-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -206.1 KB - Content
- image-20220906101320-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.1 KB - Content
- image-20220906102307-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.3 KB - Content
- image-20220927095645-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -174.1 KB - Content
- image-20221006192726-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.3 KB - Content