Last modified by Xiaoling on 2023/07/18 10:12

From version 189.9
edited by Xiaoling
on 2022/08/08 16:38
Change comment: There is no comment for this version
To version 189.8
edited by Xiaoling
on 2022/08/08 16:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1026,15 +1026,12 @@
1026 1026  
1027 1027  == 2.7 Alarm Mode ==
1028 1028  
1029 -
1030 1030  (((
1031 1031  when the device is in alarm mode, it checks the built-in sensor temperature for a short time. if the temperature exceeds the preconfigured range, it sends an uplink immediately.
1032 1032  )))
1033 1033  
1034 1034  (((
1035 -(% style="color:red" %)**Note: alarm mode adds a little power consumption, and we recommend extending the normal read time when this feature is enabled.**
1036 -
1037 -
1034 +(% style="color:red" %)Note: alarm mode adds a little power consumption, and we recommend extending the normal read time when this feature is enabled.
1038 1038  )))
1039 1039  
1040 1040  (((
... ... @@ -1079,10 +1079,8 @@
1079 1079  TEMPhigh=003C
1080 1080  
1081 1081  
1082 -
1083 1083  == 2.8 LED Indicator ==
1084 1084  
1085 -
1086 1086  The LHT65 has a triple color LED which for easy showing different stage .
1087 1087  
1088 1088  While user press ACT button, the LED will work as per LED status with ACT button.
... ... @@ -1095,10 +1095,8 @@
1095 1095  * For each success downlink, the PURPLE LED will blink once
1096 1096  
1097 1097  
1098 -
1099 1099  == 2.9 installation ==
1100 1100  
1101 -
1102 1102  (% _mstvisible="1" %)
1103 1103  [[image:image-20220516231650-1.png||_mstalt="428597" _mstvisible="3" height="436" width="428"]]
1104 1104  
... ... @@ -1108,10 +1108,8 @@
1108 1108  
1109 1109  == 3.1 E2 Extension Cable ==
1110 1110  
1111 -
1112 1112  [[image:image-20220619092222-1.png||height="182" width="188"]][[image:image-20220619092313-2.png||height="182" width="173"]]
1113 1113  
1114 -
1115 1115  **1m long breakout cable for LHT65N. Features:**
1116 1116  
1117 1117  * (((
... ... @@ -1128,9 +1128,6 @@
1128 1128  )))
1129 1129  * (((
1130 1130  Exposed All pins from the LHT65N Type-C connector.
1131 -
1132 -
1133 -
1134 1134  )))
1135 1135  
1136 1136  [[image:image-20220619092421-3.png||height="371" width="529"]]
... ... @@ -1153,10 +1153,8 @@
1153 1153  * Working voltage 2.35v ~~ 5v
1154 1154  
1155 1155  
1156 -
1157 1157  = 4. Configure LHT65N via AT command or LoRaWAN downlink =
1158 1158  
1159 -
1160 1160  (((
1161 1161  Use can configure LHT65N via AT Command or LoRaWAN Downlink.
1162 1162  )))
... ... @@ -1201,13 +1201,10 @@
1201 1201  )))
1202 1202  
1203 1203  
1204 -
1205 1205  == 4.1 Set Transmit Interval Time ==
1206 1206  
1207 -
1208 1208  Feature: Change LoRaWAN End Node Transmit Interval.
1209 1209  
1210 -
1211 1211  (% style="color:#4f81bd" %)**AT Command: AT+TDC**
1212 1212  
1213 1213  [[image:image-20220523150701-2.png||_mstalt="427453" _mstvisible="3"]]
... ... @@ -1224,13 +1224,10 @@
1224 1224  * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1225 1225  
1226 1226  
1227 -
1228 1228  == 4.2 Set External Sensor Mode ==
1229 1229  
1230 -
1231 1231  Feature: Change External Sensor Mode.
1232 1232  
1233 -
1234 1234  (% style="color:#4f81bd" %)**AT Command: AT+EXT**
1235 1235  
1236 1236  [[image:image-20220523150759-3.png||_mstalt="432146" _mstvisible="3"]]
... ... @@ -1249,10 +1249,8 @@
1249 1249  * 0xA20702003c: Same as AT+SETCNT=60
1250 1250  
1251 1251  
1252 -
1253 1253  == 4.3 Enable/Disable uplink Temperature probe ID ==
1254 1254  
1255 -
1256 1256  (((
1257 1257  Feature: If PID is enabled, device will send the temperature probe ID on:
1258 1258  )))
... ... @@ -1266,8 +1266,6 @@
1266 1266  
1267 1267  (((
1268 1268  PID is default set to disable (0)
1269 -
1270 -
1271 1271  )))
1272 1272  
1273 1273  (% style="color:#4f81bd" %)**AT Command:**
... ... @@ -1281,13 +1281,10 @@
1281 1281  * **0xA801**     **~-~->** AT+PID=1
1282 1282  
1283 1283  
1284 -
1285 1285  == 4.4 Set Password ==
1286 1286  
1287 -
1288 1288  Feature: Set device password, max 9 digits
1289 1289  
1290 -
1291 1291  (% style="color:#4f81bd" %)**AT Command: AT+PWORD**
1292 1292  
1293 1293  [[image:image-20220523151052-5.png||_mstalt="428623" _mstvisible="3"]]
... ... @@ -1301,10 +1301,8 @@
1301 1301  
1302 1302  == 4.5 Quit AT Command ==
1303 1303  
1304 -
1305 1305  Feature: Quit AT Command mode, so user needs to input password again before use AT Commands.
1306 1306  
1307 -
1308 1308  (% style="color:#4f81bd" %)**AT Command: AT+DISAT**
1309 1309  
1310 1310  [[image:image-20220523151132-6.png||_mstalt="428649" _mstvisible="3"]]
... ... @@ -1318,14 +1318,11 @@
1318 1318  
1319 1319  == 4.6 Set to sleep mode ==
1320 1320  
1321 -
1322 1322  Feature: Set device to sleep mode
1323 1323  
1324 1324  * **AT+Sleep=0**  : Normal working mode, device will sleep and use lower power when there is no LoRa message
1325 1325  * **AT+Sleep=1** :  Device is in deep sleep mode, no LoRa activation happen, used for storage or shipping.
1326 1326  
1327 -
1328 -
1329 1329  (% _msthash="315251" _msttexthash="289783" style="color:#4f81bd" %)**AT Command: AT+SLEEP**
1330 1330  
1331 1331  [[image:image-20220523151218-7.png||_mstalt="430703" _mstvisible="3"]]
... ... @@ -1336,13 +1336,10 @@
1336 1336  * There is no downlink command to set to Sleep mode.
1337 1337  
1338 1338  
1339 -
1340 1340  == 4.7 Set system time ==
1341 1341  
1342 -
1343 1343  Feature: Set system time, unix format. [[See here for format detail.>>||anchor="H2.6.2UnixTimeStamp"]]
1344 1344  
1345 -
1346 1346  (% _msthash="315253" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:**
1347 1347  
1348 1348  [[image:image-20220523151253-8.png||_mstalt="430677" _mstvisible="3"]]
... ... @@ -1356,7 +1356,6 @@
1356 1356  
1357 1357  == 4.8 Set Time Sync Mode ==
1358 1358  
1359 -
1360 1360  (((
1361 1361  Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command.
1362 1362  )))
... ... @@ -1363,8 +1363,6 @@
1363 1363  
1364 1364  (((
1365 1365  SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0.
1366 -
1367 -
1368 1368  )))
1369 1369  
1370 1370  (% _msthash="506058" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:**
... ... @@ -1381,10 +1381,8 @@
1381 1381  
1382 1382  == 4.9 Set Time Sync Interval ==
1383 1383  
1384 -
1385 1385  Feature: Define System time sync interval. SYNCTDC default value: 10 days.
1386 1386  
1387 -
1388 1388  (% _msthash="315256" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:**
1389 1389  
1390 1390  [[image:image-20220523151411-10.png||_mstalt="449696" _mstvisible="3"]]
... ... @@ -1398,10 +1398,8 @@
1398 1398  
1399 1399  == 4.10 Print data entries base on page. ==
1400 1400  
1401 -
1402 1402  Feature: Print the sector data from start page to stop page (max is 416 pages).
1403 1403  
1404 -
1405 1405  (% _msthash="315258" _msttexthash="264953" style="color:#4f81bd" %)**AT Command: AT+PDTA**
1406 1406  
1407 1407  [[image:image-20220523151450-11.png||_mstalt="451035" _mstvisible="3"]]