Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20220613162008-1.png||_mstalt="428142" height="5 79" width="379"]]2 +[[image:image-20220613162008-1.png||_mstalt="428142" height="510" width="334"]] 3 3 4 4 5 5 ... ... @@ -46,6 +46,7 @@ 46 46 47 47 == 1.2 Features == 48 48 49 + 49 49 * Wall mountable 50 50 * LoRaWAN v1.0.3 Class A protocol 51 51 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915 ... ... @@ -58,9 +58,6 @@ 58 58 * Tri-color LED to indicate working status 59 59 * Datalog feature 60 60 61 - 62 - 63 - 64 64 == 1.3 Specification == 65 65 66 66 ... ... @@ -85,13 +85,11 @@ 85 85 * ±2°C accuracy from -55°C to +125°C 86 86 * Operating Range: -55 °C ~~ 125 °C 87 87 88 - 89 - 90 - 91 91 = 2. Connect LHT65N to IoT Server = 92 92 93 93 == 2.1 How does LHT65N work? == 94 94 90 + 95 95 ((( 96 96 LHT65N is configured as LoRaWAN OTAA Class A mode by default. Each LHT65N is shipped with a worldwide unique set of OTAA keys. To use LHT65N in a LoRaWAN network, first, we need to put the OTAA keys in LoRaWAN Network Server and then activate LHT65N. 97 97 ))) ... ... @@ -101,8 +101,10 @@ 101 101 ))) 102 102 103 103 100 + 104 104 == 2.2 How to Activate LHT65N? == 105 105 103 + 106 106 ((( 107 107 The LHT65N has two working modes: 108 108 ))) ... ... @@ -127,6 +127,7 @@ 127 127 128 128 == 2.3 Example to join LoRaWAN network == 129 129 128 + 130 130 (% _msthash="315240" _msttexthash="9205482" _mstvisible="1" class="wikigeneratedid" %) 131 131 This section shows an example of how to join the TTN V3 LoRaWAN IoT server. Use with other LoRaWAN IoT servers is of a similar procedure. 132 132 ... ... @@ -142,6 +142,7 @@ 142 142 143 143 === 2.3.1 Step 1: Create Device n TTN === 144 144 144 + 145 145 ((( 146 146 Create a device in TTN V3 with the OTAA keys from LHT65N. 147 147 ))) ... ... @@ -183,6 +183,7 @@ 183 183 184 184 === 2.3.2 Step 2: Activate LHT65N by pressing the ACT button for more than 5 seconds. === 185 185 186 + 186 186 ((( 187 187 Use ACT button to activate LHT65N and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel. 188 188 ))) ... ... @@ -194,6 +194,7 @@ 194 194 195 195 == 2.4 Uplink Payload == 196 196 198 + 197 197 ((( 198 198 The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% _mstvisible="3" style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default. 199 199 ))) ... ... @@ -268,12 +268,11 @@ 268 268 269 269 * The First 6 bytes: has fix meanings for every LHT65N. 270 270 * The 7th byte (EXT #): defines the external sensor model. 271 -* The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won ’t be these four bytes.)273 +* The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won't be these four bytes.) 272 272 273 - 274 - 275 275 === 2.4.1 Decoder in TTN V3 === 276 276 277 + 277 277 When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N decoder in TTNv3 for friendly reading. 278 278 279 279 Below is the position to put the decoder and LHT65N decoder can be download from here: ... ... @@ -289,6 +289,7 @@ 289 289 290 290 === 2.4.2 BAT-Battery Info === 291 291 293 + 292 292 These two bytes of BAT include the battery state and the actually voltage 293 293 294 294 [[image:image-20220523152839-18.png||_mstalt="457613" _mstvisible="3"]] ... ... @@ -302,10 +302,9 @@ 302 302 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 303 303 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 304 304 305 - 306 - 307 307 === 2.4.3 Built-in Temperature === 308 308 309 + 309 309 [[image:image-20220522235639-2.png||_mstalt="431756" _mstvisible="3" height="138" width="722"]] 310 310 311 311 * Temperature: 0x0ABB/100=27.47℃ ... ... @@ -314,18 +314,16 @@ 314 314 315 315 * Temperature: (0xF5C6-65536)/100=-26.18℃ 316 316 317 - 318 - 319 319 === 2.4.4 Built-in Humidity === 320 320 320 + 321 321 [[image:image-20220522235639-4.png||_mstalt="432484" _mstvisible="3" height="138" width="722"]] 322 322 323 323 * Humidity: 0x025C/10=60.4% 324 324 325 - 326 - 327 327 === 2.4.5 Ext # === 328 328 327 + 329 329 Bytes for External Sensor: 330 330 331 331 [[image:image-20220523152822-17.png||_mstalt="454545" _mstvisible="3"]] ... ... @@ -357,6 +357,7 @@ 357 357 358 358 ==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ==== 359 359 359 + 360 360 ((( 361 361 Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below: 362 362 ))) ... ... @@ -478,9 +478,9 @@ 478 478 * (% style="color:blue" %)**Sync time OK**: (%%) 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 479 479 * (% style="color:blue" %)**Unix Time Request**:(%%) 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 480 480 481 - 482 482 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 483 483 483 + 484 484 In this mode, user can connect external ADC sensor to check ADC value. The 3V3_OUT can 485 485 486 486 be used to power the external ADC sensor; user can control the power on time for this ... ... @@ -528,6 +528,7 @@ 528 528 529 529 == 2.5 Show data on Datacake == 530 530 531 + 531 531 ((( 532 532 Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps: 533 533 ))) ... ... @@ -575,6 +575,7 @@ 575 575 576 576 == 2.6 Datalog Feature == 577 577 579 + 578 578 ((( 579 579 Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, LHT65N will store the reading for future retrieving purposes. There are two ways for IoT servers to get datalog from LHT65N. 580 580 ))) ... ... @@ -583,6 +583,7 @@ 583 583 584 584 === 2.6.1 Ways to get datalog via LoRaWAN === 585 585 588 + 586 586 There are two methods: 587 587 588 588 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specifying time range. ... ... @@ -615,6 +615,7 @@ 615 615 616 616 === 2.6.3 Set Device Time === 617 617 621 + 618 618 ((( 619 619 There are two ways to set device's time: 620 620 ))) ... ... @@ -632,7 +632,7 @@ 632 632 ))) 633 633 634 634 ((( 635 -(% style="color:red" %)Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn ’t support. If server doesn’t support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.639 +(% style="color:red" %)**Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn't support. If server doesn't support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.** 636 636 ))) 637 637 638 638 ((( ... ... @@ -651,6 +651,7 @@ 651 651 652 652 === 2.6.4 Poll sensor value === 653 653 658 + 654 654 User can poll sensor value based on timestamps from the server. Below is the downlink command. 655 655 656 656 [[image:image-20220523152302-15.png||_mstalt="451581" _mstvisible="3"]] ... ... @@ -668,6 +668,7 @@ 668 668 669 669 === 2.6.5 Datalog Uplink payload === 670 670 676 + 671 671 (% _msthash="315267" _msttexthash="2245087" _mstvisible="1" %) 672 672 The Datalog poll reply uplink will use below payload format. 673 673 ... ... @@ -674,6 +674,9 @@ 674 674 (% _mstvisible="1" %) 675 675 ((( 676 676 (% _mstvisible="2" %) 683 + 684 + 685 +(% _mstvisible="2" %) 677 677 (% _msthash="506080" _msttexthash="451581" _mstvisible="4" %)**Retrieval data payload** 678 678 ))) 679 679 ... ... @@ -936,7 +936,7 @@ 936 936 (% _mstvisible="1" %) 937 937 ((( 938 938 (% _msthash="506083" _msttexthash="737269" _mstvisible="2" style="text-align: left;" %) 939 - Stop time 60066DA7= time 21/1/19 05:27:(% _msthash="903005" _msttexthash="9672" _mstvisible="2" %)03 948 + Stop time 60066DA7= time 21/1/19 05:27:(% _msthash="903005" _msttexthash="9672" _mstvisible="2" %)03 940 940 ))) 941 941 942 942 (% _mstvisible="1" %) ... ... @@ -998,12 +998,15 @@ 998 998 999 999 == 2.7 Alarm Mode == 1000 1000 1010 + 1001 1001 ((( 1002 1002 when the device is in alarm mode, it checks the built-in sensor temperature for a short time. if the temperature exceeds the preconfigured range, it sends an uplink immediately. 1003 1003 ))) 1004 1004 1005 1005 ((( 1006 -(% style="color:red" %)Note: alarm mode adds a little power consumption, and we recommend extending the normal read time when this feature is enabled. 1016 +(% style="color:red" %)**Note: alarm mode adds a little power consumption, and we recommend extending the normal read time when this feature is enabled.** 1017 + 1018 + 1007 1007 ))) 1008 1008 1009 1009 ((( ... ... @@ -1048,8 +1048,10 @@ 1048 1048 TEMPhigh=003C 1049 1049 1050 1050 1063 + 1051 1051 == 2.8 LED Indicator == 1052 1052 1066 + 1053 1053 The LHT65 has a triple color LED which for easy showing different stage . 1054 1054 1055 1055 While user press ACT button, the LED will work as per LED status with ACT button. ... ... @@ -1061,11 +1061,9 @@ 1061 1061 * RED LED when external sensor is not connected 1062 1062 * For each success downlink, the PURPLE LED will blink once 1063 1063 1064 - 1065 - 1066 - 1067 1067 == 2.9 installation == 1068 1068 1080 + 1069 1069 (% _mstvisible="1" %) 1070 1070 [[image:image-20220516231650-1.png||_mstalt="428597" _mstvisible="3" height="436" width="428"]] 1071 1071 ... ... @@ -1075,8 +1075,10 @@ 1075 1075 1076 1076 == 3.1 E2 Extension Cable == 1077 1077 1090 + 1078 1078 [[image:image-20220619092222-1.png||height="182" width="188"]][[image:image-20220619092313-2.png||height="182" width="173"]] 1079 1079 1093 + 1080 1080 **1m long breakout cable for LHT65N. Features:** 1081 1081 1082 1082 * ((( ... ... @@ -1093,6 +1093,9 @@ 1093 1093 ))) 1094 1094 * ((( 1095 1095 Exposed All pins from the LHT65N Type-C connector. 1110 + 1111 + 1112 + 1096 1096 ))) 1097 1097 1098 1098 [[image:image-20220619092421-3.png||height="371" width="529"]] ... ... @@ -1114,11 +1114,9 @@ 1114 1114 * Operating Range: -40 ~~ 125 °C 1115 1115 * Working voltage 2.35v ~~ 5v 1116 1116 1117 - 1118 - 1119 - 1120 1120 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1121 1121 1136 + 1122 1122 ((( 1123 1123 Use can configure LHT65N via AT Command or LoRaWAN Downlink. 1124 1124 ))) ... ... @@ -1163,10 +1163,13 @@ 1163 1163 ))) 1164 1164 1165 1165 1181 + 1166 1166 == 4.1 Set Transmit Interval Time == 1167 1167 1184 + 1168 1168 Feature: Change LoRaWAN End Node Transmit Interval. 1169 1169 1187 + 1170 1170 (% style="color:#4f81bd" %)**AT Command: AT+TDC** 1171 1171 1172 1172 [[image:image-20220523150701-2.png||_mstalt="427453" _mstvisible="3"]] ... ... @@ -1182,13 +1182,12 @@ 1182 1182 1183 1183 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1184 1184 1185 - 1186 - 1187 - 1188 1188 == 4.2 Set External Sensor Mode == 1189 1189 1205 + 1190 1190 Feature: Change External Sensor Mode. 1191 1191 1208 + 1192 1192 (% style="color:#4f81bd" %)**AT Command: AT+EXT** 1193 1193 1194 1194 [[image:image-20220523150759-3.png||_mstalt="432146" _mstvisible="3"]] ... ... @@ -1206,11 +1206,9 @@ 1206 1206 1207 1207 * 0xA20702003c: Same as AT+SETCNT=60 1208 1208 1209 - 1210 - 1211 - 1212 1212 == 4.3 Enable/Disable uplink Temperature probe ID == 1213 1213 1228 + 1214 1214 ((( 1215 1215 Feature: If PID is enabled, device will send the temperature probe ID on: 1216 1216 ))) ... ... @@ -1224,6 +1224,8 @@ 1224 1224 1225 1225 ((( 1226 1226 PID is default set to disable (0) 1242 + 1243 + 1227 1227 ))) 1228 1228 1229 1229 (% style="color:#4f81bd" %)**AT Command:** ... ... @@ -1236,13 +1236,12 @@ 1236 1236 * **0xA800** **~-~->** AT+PID=0 1237 1237 * **0xA801** **~-~->** AT+PID=1 1238 1238 1239 - 1240 - 1241 - 1242 1242 == 4.4 Set Password == 1243 1243 1258 + 1244 1244 Feature: Set device password, max 9 digits 1245 1245 1261 + 1246 1246 (% style="color:#4f81bd" %)**AT Command: AT+PWORD** 1247 1247 1248 1248 [[image:image-20220523151052-5.png||_mstalt="428623" _mstvisible="3"]] ... ... @@ -1256,8 +1256,10 @@ 1256 1256 1257 1257 == 4.5 Quit AT Command == 1258 1258 1275 + 1259 1259 Feature: Quit AT Command mode, so user needs to input password again before use AT Commands. 1260 1260 1278 + 1261 1261 (% style="color:#4f81bd" %)**AT Command: AT+DISAT** 1262 1262 1263 1263 [[image:image-20220523151132-6.png||_mstalt="428649" _mstvisible="3"]] ... ... @@ -1271,6 +1271,7 @@ 1271 1271 1272 1272 == 4.6 Set to sleep mode == 1273 1273 1292 + 1274 1274 Feature: Set device to sleep mode 1275 1275 1276 1276 * **AT+Sleep=0** : Normal working mode, device will sleep and use lower power when there is no LoRa message ... ... @@ -1285,13 +1285,12 @@ 1285 1285 1286 1286 * There is no downlink command to set to Sleep mode. 1287 1287 1288 - 1289 - 1290 - 1291 1291 == 4.7 Set system time == 1292 1292 1309 + 1293 1293 Feature: Set system time, unix format. [[See here for format detail.>>||anchor="H2.6.2UnixTimeStamp"]] 1294 1294 1312 + 1295 1295 (% _msthash="315253" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:** 1296 1296 1297 1297 [[image:image-20220523151253-8.png||_mstalt="430677" _mstvisible="3"]] ... ... @@ -1305,6 +1305,7 @@ 1305 1305 1306 1306 == 4.8 Set Time Sync Mode == 1307 1307 1326 + 1308 1308 ((( 1309 1309 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command. 1310 1310 ))) ... ... @@ -1311,6 +1311,8 @@ 1311 1311 1312 1312 ((( 1313 1313 SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0. 1333 + 1334 + 1314 1314 ))) 1315 1315 1316 1316 (% _msthash="506058" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:** ... ... @@ -1327,8 +1327,10 @@ 1327 1327 1328 1328 == 4.9 Set Time Sync Interval == 1329 1329 1351 + 1330 1330 Feature: Define System time sync interval. SYNCTDC default value: 10 days. 1331 1331 1354 + 1332 1332 (% _msthash="315256" _msttexthash="137488" style="color:#4f81bd" %)**AT Command:** 1333 1333 1334 1334 [[image:image-20220523151411-10.png||_mstalt="449696" _mstvisible="3"]] ... ... @@ -1342,8 +1342,10 @@ 1342 1342 1343 1343 == 4.10 Print data entries base on page. == 1344 1344 1368 + 1345 1345 Feature: Print the sector data from start page to stop page (max is 416 pages). 1346 1346 1371 + 1347 1347 (% _msthash="315258" _msttexthash="264953" style="color:#4f81bd" %)**AT Command: AT+PDTA** 1348 1348 1349 1349 [[image:image-20220523151450-11.png||_mstalt="451035" _mstvisible="3"]] ... ... @@ -1357,8 +1357,10 @@ 1357 1357 1358 1358 == 4.11 Print last few data entries. == 1359 1359 1385 + 1360 1360 Feature: Print the last few data entries 1361 1361 1388 + 1362 1362 (% _msthash="315260" _msttexthash="288522" style="color:#4f81bd" %)**AT Command: AT+PLDTA** 1363 1363 1364 1364 [[image:image-20220523151524-12.png||_mstalt="452101" _mstvisible="3"]] ... ... @@ -1372,6 +1372,7 @@ 1372 1372 1373 1373 == 4.12 Clear Flash Record == 1374 1374 1402 + 1375 1375 Feature: Clear flash storage for data log feature. 1376 1376 1377 1377 ... ... @@ -1384,14 +1384,13 @@ 1384 1384 1385 1385 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1386 1386 1387 - 1388 - 1389 - 1390 1390 == 4.13 Auto Send None-ACK messages == 1391 1391 1417 + 1392 1392 (% _msthash="315394" _msttexthash="51837149" _mstvisible="1" %) 1393 1393 Feature: LHT65N will wait for ACK for each uplink, If LHT65N doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. LHT65N keeps sending messages in normal periodically. Once LHT65N gets ACK from a server, it will consider the network is ok and start to send the not-arrive message. 1394 1394 1421 + 1395 1395 (% style="color:#4f81bd" %)**AT Command: AT+PNACKMD** 1396 1396 1397 1397 (% _msthash="315396" _msttexthash="734682" _mstvisible="1" %) ... ... @@ -1405,13 +1405,11 @@ 1405 1405 1406 1406 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1407 1407 1408 - 1409 - 1410 - 1411 1411 = 5. Battery & How to replace = 1412 1412 1413 1413 == 5.1 Battery Type == 1414 1414 1439 + 1415 1415 ((( 1416 1416 ((( 1417 1417 LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters. ... ... @@ -1432,8 +1432,10 @@ 1432 1432 The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery. 1433 1433 1434 1434 1460 + 1435 1435 == 5.2 Replace Battery == 1436 1436 1463 + 1437 1437 LHT65N has two screws on the back, Unscrew them, and changing the battery inside is ok. The battery is a general CR17450 battery. Any brand should be ok. 1438 1438 1439 1439 [[image:image-20220515075440-2.png||_mstalt="429546" _mstvisible="3" height="338" width="272"]][[image:image-20220515075625-3.png||_mstalt="431574" _mstvisible="3" height="193" width="257"]] ... ... @@ -1441,6 +1441,7 @@ 1441 1441 1442 1442 == 5.3 Battery Life Analyze == 1443 1443 1471 + 1444 1444 ((( 1445 1445 Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life: 1446 1446 [[https:~~/~~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf]] ... ... @@ -1458,8 +1458,10 @@ 1458 1458 1459 1459 = 6. FAQ = 1460 1460 1489 + 1461 1461 == 6.1 How to use AT Command? == 1462 1462 1492 + 1463 1463 LHT65N supports AT Command set.User can use a USB to TTL adapter plus the Program Cable to connect to LHT65 for using AT command, as below. 1464 1464 1465 1465 [[image:image-20220530085651-1.png||_mstalt="429949"]] ... ... @@ -1678,40 +1678,43 @@ 1678 1678 AT+PID: Get or set the PID 1679 1679 1680 1680 1711 + 1681 1681 == 6.2 Where to use AT commands and Downlink commands == 1682 1682 1683 -(% _msthash="506131" _msttexthash="14585714" %) 1684 -AT commands: 1685 1685 1715 +**AT commands:** 1716 + 1686 1686 [[image:image-20220620153708-1.png||height="603" width="723"]] 1687 1687 1688 -(% _msthash="506132" _msttexthash="337922" %) 1689 -Downlink commands: 1690 1690 1720 +**Downlink commands:** 1691 1691 1692 -(% _msthash="506133" _msttexthash="33046" %) 1693 -**TTN:** 1694 1694 1723 + 1724 +(% style="color:blue" %)**TTN:** 1725 + 1695 1695 [[image:image-20220615092124-2.png||_mstalt="429221" height="649" width="688"]] 1696 1696 1697 1697 1698 -(% _msthash="506134" _msttexthash="11113791" %) 1699 -**Helium:** 1700 1700 1730 +(% style="color:blue" %)**Helium:** 1731 + 1701 1701 [[image:image-20220615092551-3.png||_mstalt="430794" height="423" width="835"]] 1702 1702 1703 1703 1704 -(% _msthash="506135" _msttexthash="4159844" %) 1705 -**Chirpstack:The downlink window will not be displayed until the network is accessed** 1706 1706 1736 +(% style="color:blue" %)**Chirpstack: The downlink window will not be displayed until the network is accessed** 1737 + 1738 + 1707 1707 [[image:image-20220615094850-6.png||_mstalt="433082"]] 1708 1708 1741 + 1709 1709 [[image:image-20220615094904-7.png||_mstalt="433485" height="281" width="911"]] 1710 1710 1711 1711 1712 -(% _msthash="506136" _msttexthash="39286" %) 1713 -**Aws:** 1714 1714 1746 +(% style="color:blue" %)**Aws:** 1747 + 1715 1715 [[image:image-20220615092939-4.png||_mstalt="434460" height="448" width="894"]] 1716 1716 1717 1717 ... ... @@ -1718,6 +1718,7 @@ 1718 1718 1719 1719 == 6.3 How to change the uplink interval? == 1720 1720 1754 + 1721 1721 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20set%20the%20transmit%20time%20interval/||_msthash="506137" _msttexthash="5712018"]] 1722 1722 1723 1723 ... ... @@ -1724,6 +1724,7 @@ 1724 1724 1725 1725 == 6.4 How to use TTL-USB to connect a PC to input AT commands? == 1726 1726 1761 + 1727 1727 [[image:image-20220615153355-1.png]] 1728 1728 1729 1729 [[image:1655802313617-381.png]] ... ... @@ -1780,13 +1780,16 @@ 1780 1780 Finally, unplug the DuPont cable on port4, and then use the DuPont cable to short circuit port3 and port1 to reset the device. 1781 1781 1782 1782 1818 + 1783 1783 == 6.6 Using USB-TYPE-C to connect to the computer using the AT command == 1784 1784 1821 + 1785 1785 [[image:image-20220623110706-1.png]] 1786 1786 1787 1787 1788 1788 [[image:image-20220623112117-4.png||height="459" width="343"]] 1789 1789 1827 + 1790 1790 ((( 1791 1791 In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 1792 1792 ))) ... ... @@ -1797,10 +1797,13 @@ 1797 1797 [[image:image-20220615154519-3.png||height="672" width="807"]] 1798 1798 1799 1799 1838 + 1800 1800 == 6.7 How to use USB-TYPE-C to connect PC to upgrade firmware? == 1801 1801 1841 + 1802 1802 [[image:image-20220623110706-1.png]] 1803 1803 1844 + 1804 1804 (% style="color:blue" %)**Step1**(%%): Install TremoProgrammer first. 1805 1805 1806 1806 [[image:image-20220615170542-5.png]] ... ... @@ -1817,6 +1817,7 @@ 1817 1817 (% _msthash="506146" _msttexthash="52173160" %) 1818 1818 Press and hold the start key to restart and enter (% _mstvisible="1" %)bootlaod(%%) mode. 1819 1819 1861 + 1820 1820 (% style="color:blue" %)**Step3:**(%%)Select the device port to be connected, baud rate and bin file to be downloaded. 1821 1821 1822 1822 [[image:image-20220615171334-6.png]] ... ... @@ -1833,6 +1833,7 @@ 1833 1833 Finally,restart reset device again 1834 1834 1835 1835 1878 + 1836 1836 = 7. Order Info = 1837 1837 1838 1838 ... ... @@ -1881,6 +1881,7 @@ 1881 1881 1882 1882 = 9. Reference material = 1883 1883 1927 + 1884 1884 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1885 1885 1886 1886 ... ... @@ -1888,6 +1888,7 @@ 1888 1888 1889 1889 = 10. FCC Warning = 1890 1890 1935 + 1891 1891 This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: 1892 1892 1893 1893 (1) This device may not cause harmful interference;