Last modified by Xiaoling on 2023/07/18 10:12

From version 188.1
edited by Edwin Chen
on 2022/07/03 11:17
Change comment: There is no comment for this version
To version 189.1
edited by Bei Jinggeng
on 2022/07/06 13:48
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Bei
Content
... ... @@ -60,7 +60,6 @@
60 60  
61 61  
62 62  
63 -
64 64  == 1.3 Specification ==
65 65  
66 66  
... ... @@ -87,7 +87,6 @@
87 87  
88 88  
89 89  
90 -
91 91  = 2. Connect LHT65N to IoT Server =
92 92  
93 93  == 2.1 How does LHT65N work? ==
... ... @@ -271,7 +271,6 @@
271 271  
272 272  
273 273  
274 -
275 275  === 2.4.1 Decoder in TTN V3 ===
276 276  
277 277  When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N decoder in TTNv3 for friendly reading.
... ... @@ -304,7 +304,6 @@
304 304  
305 305  
306 306  
307 -
308 308  === 2.4.3 Built-in Temperature ===
309 309  
310 310  [[image:image-20220522235639-2.png||_mstalt="431756" _mstvisible="3" height="138" width="722"]]
... ... @@ -317,7 +317,6 @@
317 317  
318 318  
319 319  
320 -
321 321  === 2.4.4 Built-in Humidity ===
322 322  
323 323  [[image:image-20220522235639-4.png||_mstalt="432484" _mstvisible="3" height="138" width="722"]]
... ... @@ -326,7 +326,6 @@
326 326  
327 327  
328 328  
329 -
330 330  === 2.4.5 Ext # ===
331 331  
332 332  Bytes for External Sensor:
... ... @@ -481,7 +481,6 @@
481 481  
482 482  
483 483  
484 -
485 485  ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ====
486 486  
487 487  In this mode, user can connect external ADC sensor to check ADC value. The 3V3_OUT can
... ... @@ -1036,8 +1036,21 @@
1036 1036  )))
1037 1037  )))
1038 1038  
1032 +(% style="color:#4f81bd" %)**Downlink Command: AAXXXXXXXXXXXXXX**
1039 1039  
1034 +Total bytes: 8 bytes
1040 1040  
1036 +**Example:**AA0100010001003C
1037 +
1038 +WMOD=01
1039 +
1040 +CITEMP=0001
1041 +
1042 +TEMPlow=0001
1043 +
1044 +TEMPhigh=003C
1045 +
1046 +
1041 1041  == 2.8 LED Indicator ==
1042 1042  
1043 1043  The LHT65 has a triple color LED which for easy showing different stage .
... ... @@ -1053,7 +1053,6 @@
1053 1053  
1054 1054  
1055 1055  
1056 -
1057 1057  == 2.9 installation ==
1058 1058  
1059 1059  (% _mstvisible="1" %)
... ... @@ -1106,7 +1106,6 @@
1106 1106  
1107 1107  
1108 1108  
1109 -
1110 1110  = 4. Configure LHT65N via AT command or LoRaWAN downlink =
1111 1111  
1112 1112  (((
... ... @@ -1174,7 +1174,6 @@
1174 1174  
1175 1175  
1176 1176  
1177 -
1178 1178  == 4.2 Set External Sensor Mode ==
1179 1179  
1180 1180  Feature: Change External Sensor Mode.
... ... @@ -1198,7 +1198,6 @@
1198 1198  
1199 1199  
1200 1200  
1201 -
1202 1202  == 4.3 Enable/Disable uplink Temperature probe ID ==
1203 1203  
1204 1204  (((
... ... @@ -1228,7 +1228,6 @@
1228 1228  
1229 1229  
1230 1230  
1231 -
1232 1232  == 4.4 Set Password ==
1233 1233  
1234 1234  Feature: Set device password, max 9 digits
... ... @@ -1277,7 +1277,6 @@
1277 1277  
1278 1278  
1279 1279  
1280 -
1281 1281  == 4.7 Set system time ==
1282 1282  
1283 1283  Feature: Set system time, unix format. [[See here for format detail.>>||anchor="H2.6.2UnixTimeStamp"]]
... ... @@ -1376,7 +1376,6 @@
1376 1376  
1377 1377  
1378 1378  
1379 -
1380 1380  == 4.13 Auto Send None-ACK messages ==
1381 1381  
1382 1382  (% _msthash="315394" _msttexthash="51837149" _mstvisible="1" %)
... ... @@ -1397,7 +1397,6 @@
1397 1397  
1398 1398  
1399 1399  
1400 -
1401 1401  = 5. Battery & How to replace =
1402 1402  
1403 1403  == 5.1 Battery Type ==
... ... @@ -1852,7 +1852,6 @@
1852 1852  
1853 1853  
1854 1854  
1855 -
1856 1856  = 8. Packing Info =
1857 1857  
1858 1858  
... ... @@ -1868,7 +1868,6 @@
1868 1868  
1869 1869  
1870 1870  
1871 -
1872 1872  = 9. Reference material =
1873 1873  
1874 1874  * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]]
... ... @@ -1875,7 +1875,6 @@
1875 1875  
1876 1876  
1877 1877  
1878 -
1879 1879  = 10. FCC Warning =
1880 1880  
1881 1881  This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: