Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
From version 185.1
edited by Bei Jinggeng
on 2022/06/28 15:12
on 2022/06/28 15:12
Change comment:
There is no comment for this version
To version 184.1
edited by Bei Jinggeng
on 2022/06/28 15:11
on 2022/06/28 15:11
Change comment:
Uploaded new attachment "image-20220628151143-7.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -59,6 +59,7 @@ 59 59 * Datalog feature 60 60 61 61 62 + 62 62 == 1.3 Specification == 63 63 64 64 ... ... @@ -84,6 +84,7 @@ 84 84 * Operating Range: -55 °C ~~ 125 °C 85 85 86 86 88 + 87 87 = 2. Connect LHT65N to IoT Server = 88 88 89 89 == 2.1 How does LHT65N work? == ... ... @@ -265,6 +265,7 @@ 265 265 * The 7th byte (EXT #): defines the external sensor model. 266 266 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 267 267 270 + 268 268 === 2.4.1 Decoder in TTN V3 === 269 269 270 270 When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N decoder in TTNv3 for friendly reading. ... ... @@ -295,6 +295,7 @@ 295 295 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 296 296 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 297 297 301 + 298 298 === 2.4.3 Built-in Temperature === 299 299 300 300 [[image:image-20220522235639-2.png||_mstalt="431756" _mstvisible="3" height="138" width="722"]] ... ... @@ -305,6 +305,7 @@ 305 305 306 306 * Temperature: (0xF5C6-65536)/100=-26.18℃ 307 307 312 + 308 308 === 2.4.4 Built-in Humidity === 309 309 310 310 [[image:image-20220522235639-4.png||_mstalt="432484" _mstvisible="3" height="138" width="722"]] ... ... @@ -311,6 +311,7 @@ 311 311 312 312 * Humidity: 0x025C/10=60.4% 313 313 319 + 314 314 === 2.4.5 Ext # === 315 315 316 316 Bytes for External Sensor: ... ... @@ -463,6 +463,7 @@ 463 463 * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 464 464 * Unix Time Request: 1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 465 465 472 + 466 466 ==== 2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable) ==== 467 467 468 468 In this mode, user can connect external ADC sensor to check ADC value. The 3V3_OUT can ... ... @@ -473,42 +473,8 @@ 473 473 474 474 AT+EXT=6,timeout (% _msthash="506085" _msttexthash="8782189" _mstvisible="3" style="color:red" %)Time to power this sensor, from 0 ~~ 65535ms 475 475 476 -For example: 477 477 478 -AT+EXT=6,1000 will power this sensor for 1000ms before sampling the ADC value. 479 479 480 - 481 -Or use **downlink command A2** to set the same. 482 - 483 -The measuring range of the node is only about 0.1V to 1.1V The voltage resolution is about 0.24mv. 484 - 485 -When the measured output voltage of the sensor is not within the range of 0.1V and 1.1V, the output voltage terminal of the sensor shall be divided The example in the following figure is to reduce the output voltage of the sensor by three times If it is necessary to reduce more times, calculate according to the formula in the figure and connect the corresponding resistance in series. 486 - 487 -[[image:image-20220628150112-1.png||height="241" width="285"]] 488 - 489 - 490 -When ADC_IN1 pin is connected to GND or suspended, ADC value is 0 491 - 492 -[[image:image-20220628150714-4.png]] 493 - 494 - 495 -When the voltage collected by ADC_IN1 is less than the minimum range, the minimum range will be used as the output; Similarly, when the collected voltage is greater than the maximum range, the maximum range will be used as the output. 496 - 497 -1) The minimum range is about 0.1V. Each chip has internal calibration, so this value is close to 0.1V 498 - 499 -[[image:image-20220628151005-5.png]] 500 - 501 - 502 -2) The maximum range is about 1.1V. Each chip has internal calibration, so this value is close to 1.1v 503 - 504 -[[image:image-20220628151056-6.png]] 505 - 506 - 507 -3) Within range 508 - 509 -[[image:image-20220628151143-7.png]] 510 - 511 - 512 512 == 2.5 Show data on Datacake == 513 513 514 514 ((( ... ... @@ -571,6 +571,7 @@ 571 571 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 572 572 1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover. 573 573 547 + 574 574 === 2.6.2 Unix TimeStamp === 575 575 576 576 ... ... @@ -1026,6 +1026,7 @@ 1026 1026 * RED LED when external sensor is not connected 1027 1027 * For each success downlink, the PURPLE LED will blink once 1028 1028 1003 + 1029 1029 == 2.9 installation == 1030 1030 1031 1031 (% _mstvisible="1" %) ... ... @@ -1076,6 +1076,7 @@ 1076 1076 * Operating Range: -40 ~~ 125 °C 1077 1077 * Working voltage 2.35v ~~ 5v 1078 1078 1054 + 1079 1079 = 4. Configure LHT65N via AT command or LoRaWAN downlink = 1080 1080 1081 1081 ((( ... ... @@ -1141,6 +1141,7 @@ 1141 1141 1142 1142 * **Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1143 1143 1120 + 1144 1144 == 4.2 Set External Sensor Mode == 1145 1145 1146 1146 Feature: Change External Sensor Mode. ... ... @@ -1162,6 +1162,7 @@ 1162 1162 1163 1163 * 0xA20702003c: Same as AT+SETCNT=60 1164 1164 1142 + 1165 1165 == 4.3 Enable/Disable uplink Temperature probe ID == 1166 1166 1167 1167 ((( ... ... @@ -1189,6 +1189,7 @@ 1189 1189 * **0xA800** **~-~->** AT+PID=0 1190 1190 * **0xA801** **~-~->** AT+PID=1 1191 1191 1170 + 1192 1192 == 4.4 Set Password == 1193 1193 1194 1194 Feature: Set device password, max 9 digits ... ... @@ -1235,6 +1235,7 @@ 1235 1235 1236 1236 * There is no downlink command to set to Sleep mode. 1237 1237 1217 + 1238 1238 == 4.7 Set system time == 1239 1239 1240 1240 Feature: Set system time, unix format. [[See here for format detail.>>||anchor="H2.6.2UnixTimeStamp"]] ... ... @@ -1331,6 +1331,7 @@ 1331 1331 1332 1332 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1333 1333 1314 + 1334 1334 == 4.13 Auto Send None-ACK messages == 1335 1335 1336 1336 (% _msthash="315394" _msttexthash="51837149" _mstvisible="1" %) ... ... @@ -1349,6 +1349,7 @@ 1349 1349 1350 1350 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1351 1351 1333 + 1352 1352 = 5. Battery & How to replace = 1353 1353 1354 1354 == 5.1 Battery Type == ... ... @@ -1801,6 +1801,7 @@ 1801 1801 1802 1802 * (% style="color:red" %)**E3**(%%): External Temperature Probe 1803 1803 1786 + 1804 1804 = 8. Packing Info = 1805 1805 1806 1806 ... ... @@ -1814,10 +1814,12 @@ 1814 1814 * Device Size: 10 x 10 x 3.5 cm 1815 1815 * Device Weight: 120.5g 1816 1816 1800 + 1817 1817 = 9. Reference material = 1818 1818 1819 1819 * [[Datasheet, photos, decoder, firmware>>https://www.dropbox.com/sh/una19zsni308dme/AACOKp6J2RF5TMlKWT5zU3RTa?dl=0||_msthash="504975" _msttexthash="51420512"]] 1820 1820 1805 + 1821 1821 = 10. FCC Warning = 1822 1822 1823 1823 This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions: