Last modified by Xiaoling on 2023/07/18 10:12

From version 166.9
edited by Xiaoling
on 2022/06/21 10:39
Change comment: There is no comment for this version
To version 166.16
edited by Xiaoling
on 2022/06/21 10:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -365,6 +365,9 @@
365 365  * The 7th byte (EXT #): defines the external sensor model.
366 366  * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.)
367 367  
368 +
369 +
370 +
368 368  (% _mstvisible="1" %)
369 369  === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) ===
370 370  
... ... @@ -401,6 +401,9 @@
401 401  * BAT status=(0Xcba4>>14)&0xFF=11(B),very good
402 402  * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
403 403  
407 +
408 +
409 +
404 404  (% _mstvisible="1" %)
405 405  === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) ===
406 406  
... ... @@ -416,6 +416,9 @@
416 416  (% _mstvisible="1" %)
417 417  * Temperature:  (0xF5C6-65536)/100=-26.18℃
418 418  
425 +
426 +
427 +
419 419  (% _mstvisible="1" %)
420 420  === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) ===
421 421  
... ... @@ -425,6 +425,9 @@
425 425  (% _mstvisible="1" %)
426 426  * Humidity:    0x025C/10=60.4%
427 427  
437 +
438 +
439 +
428 428  (% _mstvisible="1" %)
429 429  === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) ===
430 430  
... ... @@ -591,6 +591,9 @@
591 591  * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server.
592 592  * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this)
593 593  
606 +
607 +
608 +
594 594  ==== (% _msthash="1389752" _msttexthash="1234766" _mstvisible="3" %)2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable)(%%) ====
595 595  
596 596  In this mode, user can connect external ADC sensor to check ADC value. The 3V3_OUT can
... ... @@ -665,6 +665,9 @@
665 665  1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
666 666  1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
667 667  
683 +
684 +
685 +
668 668  (% _mstvisible="1" %)
669 669  === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) ===
670 670