Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -425,9 +425,6 @@ 425 425 (% _mstvisible="1" %) 426 426 * Humidity: 0x025C/10=60.4% 427 427 428 - 429 - 430 - 431 431 (% _mstvisible="1" %) 432 432 === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) === 433 433 ... ... @@ -594,9 +594,6 @@ 594 594 * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server. 595 595 * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this) 596 596 597 - 598 - 599 - 600 600 ==== (% _msthash="1389752" _msttexthash="1234766" _mstvisible="3" %)2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable)(%%) ==== 601 601 602 602 In this mode, user can connect external ADC sensor to check ADC value. The 3V3_OUT can ... ... @@ -671,9 +671,6 @@ 671 671 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 672 672 1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover. 673 673 674 - 675 - 676 - 677 677 (% _mstvisible="1" %) 678 678 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 679 679 ... ... @@ -1200,9 +1200,6 @@ 1200 1200 * -55°C to 125°C 1201 1201 * Working voltage 2.35v ~~ 5v 1202 1202 1203 - 1204 - 1205 - 1206 1206 (% _mstvisible="1" style="text-align: left;" %) 1207 1207 = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) = 1208 1208 ... ... @@ -1418,9 +1418,6 @@ 1418 1418 * 0xA800 **~-~->** AT+PID=0 1419 1419 * 0xA801 **~-~->** AT+PID=1 1420 1420 1421 - 1422 - 1423 - 1424 1424 (% _mstvisible="1" style="text-align: left;" %) 1425 1425 == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) == 1426 1426 ... ... @@ -1486,7 +1486,6 @@ 1486 1486 (% _mstvisible="1" %) 1487 1487 [[image:image-20220523151218-7.png||_mstalt="430703" _mstvisible="3"]] 1488 1488 1489 - 1490 1490 (% _mstvisible="1" %) 1491 1491 (% _msthash="315252" _msttexthash="298038" style="color:#4f81bd" %)**Downlink Command:** 1492 1492