Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -77,6 +77,8 @@ 77 77 * Tri-color LED to indicate working status 78 78 * Datalog feature 79 79 80 + 81 + 80 80 (% _mstvisible="1" %) 81 81 == (% _msthash="323570" _msttexthash="297635" _mstvisible="3" %)1.3 Specification(%%) == 82 82 ... ... @@ -365,6 +365,8 @@ 365 365 * The 7th byte (EXT #): defines the external sensor model. 366 366 * The 8(% _msthash="734578" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) ~~ 11(% _msthash="734579" _msttexthash="21372" _mstvisible="4" %)^^th^^(%%) byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.) 367 367 370 + 371 + 368 368 (% _mstvisible="1" %) 369 369 === (% _msthash="360269" _msttexthash="333762" _mstvisible="3" %)2.4.1 Decoder in TTN V3(%%) === 370 370 ... ... @@ -401,6 +401,8 @@ 401 401 * BAT status=(0Xcba4>>14)&0xFF=11(B),very good 402 402 * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV 403 403 408 + 409 + 404 404 (% _mstvisible="1" %) 405 405 === (% _msthash="600769" _msttexthash="565838" _mstvisible="3" %)2.4.3 Built-in Temperature(%%) === 406 406 ... ... @@ -416,6 +416,8 @@ 416 416 (% _mstvisible="1" %) 417 417 * Temperature: (0xF5C6-65536)/100=-26.18℃ 418 418 425 + 426 + 419 419 (% _mstvisible="1" %) 420 420 === (% _msthash="475891" _msttexthash="445120" _mstvisible="3" %)2.4.4 Built-in Humidity(%%) === 421 421 ... ... @@ -425,6 +425,8 @@ 425 425 (% _mstvisible="1" %) 426 426 * Humidity: 0x025C/10=60.4% 427 427 436 + 437 + 428 428 (% _mstvisible="1" %) 429 429 === (% _msthash="116532" _msttexthash="87958" _mstvisible="3" %)2.4.5 Ext #(%%) === 430 430 ... ... @@ -593,7 +593,6 @@ 593 593 594 594 595 595 596 - 597 597 ==== (% _msthash="1389752" _msttexthash="1234766" _mstvisible="3" %)2.4.6.3 Ext~=6, ADC Sensor (use with E2 Cable)(%%) ==== 598 598 599 599 In this mode, user can connect external ADC sensor to check ADC value. The 3V3_OUT can ... ... @@ -670,7 +670,6 @@ 670 670 671 671 672 672 673 - 674 674 (% _mstvisible="1" %) 675 675 === (% _msthash="369915" _msttexthash="342797" _mstvisible="3" %)2.6.2 Unix TimeStamp(%%) === 676 676 ... ... @@ -1180,7 +1180,7 @@ 1180 1180 1181 1181 1182 1182 (% _msthidden="1" _mstvisible="1" style="text-align: left;" %) 1183 -== (% _msthash="903005" _msttexthash="1647204" _mstvisible="2" %)3. 1(% _msthash="487110" _msttexthash="455390" %) E3 Temperature Probe(%%) ==1191 +== (% _msthash="903005" _msttexthash="1647204" _mstvisible="2" %)3.2(% _msthash="487110" _msttexthash="455390" %) E3 Temperature Probe(%%) == 1184 1184 1185 1185 (% _mstvisible="1" %) 1186 1186 [[image:image-20220515080154-4.png||_mstalt="434681" _mstvisible="3" alt="photo-20220515080154-4.png" height="182" width="161"]] [[image:image-20220515080330-5.png||_mstalt="428792" _mstvisible="3" height="201" width="195"]] ... ... @@ -1194,12 +1194,10 @@ 1194 1194 * ±0.5°C accuracy from -10°C to +85°C 1195 1195 * ±2°C accuracy from -55°C to +125°C 1196 1196 * Operating Range: -40 ~~ 125 °C 1197 -* -55°C to 125°C 1198 1198 * Working voltage 2.35v ~~ 5v 1199 1199 1200 1200 1201 1201 1202 - 1203 1203 (% _mstvisible="1" style="text-align: left;" %) 1204 1204 = (% _msthash="1940107" _msttexthash="1714063" _mstvisible="3" %)4. Configure LHT65N via AT command or LoRaWAN downlink(%%) = 1205 1205 ... ... @@ -1417,7 +1417,6 @@ 1417 1417 1418 1418 1419 1419 1420 - 1421 1421 (% _mstvisible="1" style="text-align: left;" %) 1422 1422 == (% _msthash="266344" _msttexthash="242879" _mstvisible="3" %)4.4 Set Password(%%) == 1423 1423 ... ... @@ -1492,7 +1492,6 @@ 1492 1492 1493 1493 1494 1494 1495 - 1496 1496 (% _mstvisible="1" %) 1497 1497 == (% _msthash="336557" _msttexthash="309712" _mstvisible="3" %)4.7 Set system time(%%) == 1498 1498 ... ... @@ -1629,7 +1629,6 @@ 1629 1629 1630 1630 1631 1631 1632 - 1633 1633 (% _mstvisible="1" %) 1634 1634 == (% _msthash="740532" _msttexthash="701363" _mstvisible="3" %)4.13 Auto Send None-ACK messages(%%) == 1635 1635 ... ... @@ -1655,7 +1655,6 @@ 1655 1655 1656 1656 1657 1657 1658 - 1659 1659 (% _mstvisible="1" %) 1660 1660 = (% _msthash="568737" _msttexthash="502827" _mstvisible="3" %)5. Battery & How to replace(%%) = 1661 1661 ... ... @@ -1993,22 +1993,13 @@ 1993 1993 1994 1994 [[image:image-20220615153355-1.png]] 1995 1995 1996 -[[image: image-20220620154900-5.jpeg||height="427" width="570"]]1998 +[[image:1655802313617-381.png]] 1997 1997 1998 -(% style="background-color:yellow" %)**1 < - -> GND < - -> Black** 1999 1999 2000 -(% style="background-color:yellow" %)**5 < - -> RXD < - -> White** 2001 - 2002 -(% style="background-color:yellow" %)**9 < - -> TXD < - -> Green** 2003 - 2004 - 2005 -To switch from download mode to command mode, press reset key 2006 - 2007 - 2008 2008 ((( 2009 2009 (% _msthash="736728" _msttexthash="67213055" %) 2010 2010 ((( 2011 -In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:re d" %)**123456**)(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout.2004 +In PC, User needs to set serial tool(such as [[**putty**>>https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600** (%%)to access to access serial console for LHT65N. The AT commands are disable by default and need to enter password (default:(% style="color:green" %)**123456**(% style="color:red" %))(%%) to active it. Timeout to input AT Command is 5 min, after 5-minute, user need to input password again. User can use AT+DISAT command to disable AT command before timeout. 2012 2012 ))) 2013 2013 ))) 2014 2014 ... ... @@ -2045,11 +2045,21 @@ 2045 2045 2046 2046 [[image:image-20220615170542-5.png]] 2047 2047 2041 +(% style="display:none" %) (%%) 2048 2048 2049 2049 (% _msthash="506146" _msttexthash="52173160" %) 2050 -(% _istranslated="1" %)**Step2**(%%): Download theLHT65Nimagefiles.2044 +(% _istranslated="1" %)**Step2**(%%):wiring method.(% style="display:none" %) 2051 2051 2046 +(% _msthash="506146" _msttexthash="52173160" %) 2047 +First connect the four lines;(% style="display:none" %) 2052 2052 2049 +[[image:image-20220621170938-1.png||height="413" width="419"]](% _mstvisible="1" %),(% style="display:none" %) 2050 + 2051 + 2052 +(% _mstvisible="1" %)Then use DuPont cable to short circuit port3 and port1, and then release them, so that the device enters bootlaod mode. 2053 + 2054 +[[image:image-20220621170938-2.png]]. 2055 + 2053 2053 (% _msthash="506147" _msttexthash="188083584" %) 2054 2054 (% _istranslated="1" %)**Step3:**(%%)Select the serial port and baud rate of the device and the firmware to be upgraded. 2055 2055 ... ... @@ -2188,7 +2188,6 @@ 2188 2188 2189 2189 2190 2190 2191 - 2192 2192 = (% _msthash="216320" _msttexthash="10002096" %)10. (%%)FCC Warning = 2193 2193 2194 2194 (% _mstvisible="1" %)
- 1655802313617-381.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +462.2 KB - Content
- image-20220621170938-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +737.2 KB - Content
- image-20220621170938-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +437.4 KB - Content