Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -134,7 +134,7 @@ 134 134 135 135 [[image:image-20220515123819-1.png||height="379" width="317"]] 136 136 137 -[[image:image-2022052 5110604-2.png]]137 +[[image:image-20220523153201-19.png||height="180" width="818"]] 138 138 139 139 == 2.3 Example to join LoRaWAN network == 140 140 ... ... @@ -205,10 +205,10 @@ 205 205 |(% style="width:97px" %)((( 206 206 **Value** 207 207 )))|(% style="width:39px" %)((( 208 -[[BAT>> ||anchor="H2.4.2BAT-BatteryInfo"]]208 +[[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]] 209 209 )))|(% style="width:100px" %)((( 210 210 ((( 211 -[[Built-In Temperature>> ||anchor="H2.4.3Built-inTemperature"]]211 +[[Built-In Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]] 212 212 ))) 213 213 )))|(% style="width:77px" %)((( 214 214 ((( ... ... @@ -401,17 +401,10 @@ 401 401 402 402 == 2.6 Datalog Feature == 403 403 404 - DatalogFeature istoensureIoTServer cangetallsamplingdatafromSensor even iftheLoRaWANnetworkis down.For eachsampling,LHT65Nwill store thereading for futureretrievingpurposes. Therearetwo ways forIoT serversto getdatalog from LHT65N.404 +This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot. 405 405 406 -=== 2.6.1 Waysto getdatalogvia LoRaWAN===406 +=== 2.6.1 Unix TimeStamp === 407 407 408 -There are two methods: 409 - 410 -1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 411 -1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover. 412 - 413 -=== 2.6.2 Unix TimeStamp === 414 - 415 415 LHT65N uses Unix TimeStamp format based on 416 416 417 417 [[image:image-20220523001219-11.png||height="97" width="627"]] ... ... @@ -429,7 +429,7 @@ 429 429 430 430 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 431 431 432 -=== 2.6. 3Set Device Time ===425 +=== 2.6.2 Set Device Time === 433 433 434 434 ((( 435 435 There are two ways to set device’s time: ... ... @@ -463,7 +463,7 @@ 463 463 User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server. 464 464 ))) 465 465 466 -=== 2.6. 4Poll sensor value ===459 +=== 2.6.3 Poll sensor value === 467 467 468 468 User can poll sensor value based on timestamps from the server. Below is the downlink command. 469 469 ... ... @@ -486,7 +486,7 @@ 486 486 ))) 487 487 488 488 489 -=== 2.6. 5Datalog Uplink payload ===482 +=== 2.6.4 Datalog Uplink payload === 490 490 491 491 The Datalog poll reply uplink will use below payload format. 492 492 ... ... @@ -996,22 +996,6 @@ 996 996 997 997 * Example: 0xA301 ~/~/Same as AT+CLRDTA 998 998 999 -== 4.13 Auto Send None-ACK messages == 1000 - 1001 -Feature: LHT65N will wait for ACK for each uplink, If LHT65N doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. LHT65N keeps sending messages in normal periodically. Once LHT65N gets ACK from a server, it will consider the network is ok and start to send the not-arrive message. 1002 - 1003 - 1004 -**AT Command: AT+PNACKMD** 1005 - 1006 -The default factory setting is 0 1007 - 1008 -|**Command Example**|**Function**|**Response** 1009 -|AT+PNACKMD=1|Poll None-ACK message|OK 1010 - 1011 -**Downlink Command: 0x34** 1012 - 1013 -* Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1014 - 1015 1015 = 5. Battery & How to replace = 1016 1016 1017 1017 == 5.1 Battery Type ==
- image-20220525110512-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.7 KB - Content
- image-20220525110604-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.0 KB - Content