Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -136,12 +136,6 @@ 136 136 137 137 [[image:image-20220523153201-19.png||height="180" width="818"]] 138 138 139 -(% border="1" style="background-color:#ffffcc; color:green; width:878px" %) 140 -|=**Behavior on ACT**|=**Function**|=(% style="width: 561px;" %)**Action** 141 -|**Pressing ACT between 1s < time < 3s**|Test uplink status|(% style="width:561px" %)If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once. 142 -|**Pressing ACT for more than 3s**|Active Device|(% style="width:561px" %)green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network. 143 -|**Fast press ACT 5 times**|Deactivate Device|(% style="width:561px" %)red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode. 144 - 145 145 == 2.3 Example to join LoRaWAN network == 146 146 147 147 (% class="wikigeneratedid" %) ... ... @@ -211,10 +211,10 @@ 211 211 |(% style="width:97px" %)((( 212 212 **Value** 213 213 )))|(% style="width:39px" %)((( 214 -[[BAT>> ||anchor="H2.4.2BAT-BatteryInfo"]]208 +[[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]] 215 215 )))|(% style="width:100px" %)((( 216 216 ((( 217 -[[Built-In Temperature>> ||anchor="H2.4.3Built-inTemperature"]]211 +[[Built-In Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]] 218 218 ))) 219 219 )))|(% style="width:77px" %)((( 220 220 ((( ... ... @@ -414,7 +414,7 @@ 414 414 There are two methods: 415 415 416 416 1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range. 417 -1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will sendall messages after network recover.411 +1. Set PNACKMD=1, LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will sent all messages after network recover. 418 418 419 419 === 2.6.2 Unix TimeStamp === 420 420 ... ... @@ -1002,6 +1002,7 @@ 1002 1002 1003 1003 * Example: 0xA301 ~/~/Same as AT+CLRDTA 1004 1004 999 + 1005 1005 == 4.13 Auto Send None-ACK messages == 1006 1006 1007 1007 Feature: LHT65N will wait for ACK for each uplink, If LHT65N doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. LHT65N keeps sending messages in normal periodically. Once LHT65N gets ACK from a server, it will consider the network is ok and start to send the not-arrive message. ... ... @@ -1014,10 +1014,12 @@ 1014 1014 |**Command Example**|**Function**|**Response** 1015 1015 |AT+PNACKMD=1|Poll None-ACK message|OK 1016 1016 1012 + 1017 1017 **Downlink Command: 0x34** 1018 1018 1019 1019 * Example: 0x3401 ~/~/Same as AT+PNACKMD=1 1020 1020 1017 + 1021 1021 = 5. Battery & How to replace = 1022 1022 1023 1023 == 5.1 Battery Type ==
- image-20220525110512-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.7 KB - Content
- image-20220525110604-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.0 KB - Content