<
From version < 96.2 >
edited by Xiaoling
on 2022/05/25 11:04
To version < 91.1 >
edited by Edwin Chen
on 2022/05/25 00:47
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -136,12 +136,6 @@
136 136  
137 137  [[image:image-20220523153201-19.png||height="180" width="818"]]
138 138  
139 -(% border="1" style="background-color:#ffffcc; color:green; width:878px" %)
140 -|=**Behavior on ACT**|=**Function**|=(% style="width: 561px;" %)**Action**
141 -|**Pressing ACT between 1s < time < 3s**|Test uplink status|(% style="width:561px" %)If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once.
142 -|**Pressing ACT for more than 3s**|Active Device|(% style="width:561px" %)green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network.
143 -|**Fast press ACT 5 times**|Deactivate Device|(% style="width:561px" %)red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode.
144 -
145 145  == 2.3 Example to join LoRaWAN network ==
146 146  
147 147  (% class="wikigeneratedid" %)
... ... @@ -211,10 +211,10 @@
211 211  |(% style="width:97px" %)(((
212 212  **Value**
213 213  )))|(% style="width:39px" %)(((
214 -[[BAT>>||anchor="H2.4.2BAT-BatteryInfo"]]
208 +[[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]]
215 215  )))|(% style="width:100px" %)(((
216 216  (((
217 -[[Built-In Temperature>>||anchor="H2.4.3Built-inTemperature"]]
211 +[[Built-In Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
218 218  )))
219 219  )))|(% style="width:77px" %)(((
220 220  (((
... ... @@ -414,7 +414,7 @@
414 414  There are two methods:
415 415  
416 416  1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
417 -1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
411 +1. Set [[PNACKMD=1>>||anchor="#H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will sent all messages after network recover.
418 418  
419 419  === 2.6.2 Unix TimeStamp ===
420 420  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0