... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:image-20220523115324-1.jpeg||height="317" width="317"]]
2 +[[image:image-20220523115324-1.jpeg||height="500" width="500"]]
3 3  
4 4  
5 5  **LHT65N LoRaWAN Temperature & Humidity Sensor Manual**
... ... @@ -14,7 +14,7 @@
14 14  
15 15  
16 16  
17 -= 1. Introduction =
17 += 1.Introduction =
18 18  
19 19  == 1.1 What is LHT65N Temperature & Humidity Sensor ==
20 20  
... ... @@ -208,7 +208,7 @@
208 208  [[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]]
209 209  )))|(% style="width:100px" %)(((
210 210  (((
211 -[[Built-In Temperature>>||anchor="#H2.4.3Built-inTemperature"]]
211 +[[Built-In Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
212 212  )))
213 213  )))|(% style="width:77px" %)(((
214 214  (((
... ... @@ -401,17 +401,10 @@
401 401  
402 402  == 2.6 Datalog Feature ==
403 403  
404 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, LHT65N will store the reading for future retrieving purposes. There are two ways for IoT servers to get datalog from LHT65N.
404 +This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
405 405  
406 -=== 2.6.1 Ways to get datalog via LoRaWAN ===
406 +=== 2.6.1 Unix TimeStamp ===
407 407  
408 -There are two methods:
409 -
410 -1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
411 -1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
412 -
413 -=== 2.6.2 Unix TimeStamp ===
414 -
415 415  LHT65N uses Unix TimeStamp format based on
416 416  
417 417  [[image:image-20220523001219-11.png||height="97" width="627"]]
... ... @@ -429,7 +429,7 @@
429 429  
430 430  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
431 431  
432 -=== 2.6.3 Set Device Time ===
425 +=== 2.6.2 Set Device Time ===
433 433  
434 434  (((
435 435  There are two ways to set device’s time:
... ... @@ -463,7 +463,7 @@
463 463  User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
464 464  )))
465 465  
466 -=== 2.6.4 Poll sensor value ===
459 +=== 2.6.3 Poll sensor value ===
467 467  
468 468  User can poll sensor value based on timestamps from the server. Below is the downlink command.
469 469  
... ... @@ -486,7 +486,7 @@
486 486  )))
487 487  
488 488  
489 -=== 2.6.5 Datalog Uplink payload ===
482 +=== 2.6.4 Datalog Uplink payload ===
490 490  
491 491  The Datalog poll reply uplink will use below payload format.
492 492  
... ... @@ -996,22 +996,6 @@
996 996  
997 997  * Example: 0xA301 ~/~/Same as AT+CLRDTA
998 998  
999 -== 4.13 Auto Send None-ACK messages ==
1000 -
1001 -Feature: LHT65N will wait for ACK for each uplink, If LHT65N doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. LHT65N keeps sending messages in normal periodically. Once LHT65N gets ACK from a server, it will consider the network is ok and start to send the not-arrive message.
1002 -
1003 -
1004 -**AT Command: AT+PNACKMD**
1005 -
1006 -The default factory setting is 0
1007 -
1008 -|**Command Example**|**Function**|**Response**
1009 -|AT+PNACKMD=1|Poll None-ACK message|OK
1010 -
1011 -**Downlink Command: 0x34**
1012 -
1013 -* Example: 0x3401 ~/~/Same as AT+PNACKMD=1
1014 -
1015 1015  = 5. Battery & How to replace =
1016 1016  
1017 1017  == 5.1 Battery Type ==
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved