<
From version < 94.1 >
edited by Edwin Chen
on 2022/05/25 10:27
To version < 55.2 >
edited by Xiaoling
on 2022/05/23 11:28
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -1,46 +1,28 @@
1 1  (% style="text-align:center" %)
2 -[[image:image-20220523115324-1.jpeg||height="317" width="317"]]
2 +[[image:image-20220523111447-1.jpeg||height="448" width="448"]]
3 3  
4 +{{box cssClass="floatinginfobox" title="**Contents**"}}
5 +{{toc/}}
6 +{{/box}}
4 4  
5 -**LHT65N LoRaWAN Temperature & Humidity Sensor Manual**
6 -
7 -
8 -
9 -
10 -**Table of Contents:**
11 -
12 12  {{toc/}}
13 13  
10 += 1.Introduction =
14 14  
15 -
16 -
17 -= 1. Introduction =
18 -
19 19  == 1.1 What is LHT65N Temperature & Humidity Sensor ==
20 20  
21 -(((
22 -The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a (% style="color:#4f81bd" %)**built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% style="color:#4f81bd" %)**Temperature Sensor**(%%)**.**
23 -)))
24 24  
25 -(((
15 +The Dragino LHT65N Temperature & Humidity sensor is a Long Range LoRaWAN Sensor. It includes a(% class="mark" %) **built-in Temperature & Humidity sensor**(%%) and has an external sensor connector to connect to an external (% class="mark" %)**Temperature Sensor**(%%)**.**
16 +
26 26  The LHT65N allows users to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, building automation, and so on.
27 -)))
28 28  
29 -(((
30 30  LHT65N has a built-in 2400mAh non-chargeable battery which can be used for up to 10 years*.
31 -)))
32 32  
33 -(((
34 34  LHT65N is full compatible with LoRaWAN v1.0.3 Class A protocol, it can work with a standard LoRaWAN gateway.
35 -)))
36 36  
37 -(((
38 -LHT65N supports (% style="color:#4f81bd" %)**Datalog Feature**(%%). It will record the data when there is no network coverage and users can retrieve the sensor value later to ensure no miss for every sensor reading.
39 -)))
23 +LHT65N supports (% class="mark" %)Datalog Feature(%%). It will record the data when there is no network coverage and users can retrieve the sensor value later to ensure no miss for every sensor reading.
40 40  
41 -(((
42 42  *The actual battery life depends on how often to send data, please see the battery analyzer chapter.
43 -)))
44 44  
45 45  == 1.2 Features ==
46 46  
... ... @@ -58,69 +58,36 @@
58 58  
59 59  == 1.3 Specification ==
60 60  
61 -(((
62 62  **Built-in Temperature Sensor:**
63 -)))
64 64  
65 -* (((
66 -Resolution: 0.01 °C
67 -)))
68 -* (((
69 -Accuracy Tolerance : Typ ±0.3 °C
70 -)))
71 -* (((
72 -Long Term Drift: < 0.02 °C/yr
73 -)))
74 -* (((
75 -Operating Range: -40 ~~ 85 °C
76 -)))
45 +* Resolution: 0.01 °C
46 +* Accuracy Tolerance : Typ ±0.3 °C
47 +* Long Term Drift: < 0.02 °C/yr
48 +* Operating Range: -40 ~~ 85 °C
77 77  
78 -(((
79 79  **Built-in Humidity Sensor:**
80 -)))
81 81  
82 -* (((
83 -Resolution: 0.04 %RH
84 -)))
85 -* (((
86 -Accuracy Tolerance : Typ ±3 %RH
87 -)))
88 -* (((
89 -Long Term Drift: < 0.02 °C/yr
90 -)))
91 -* (((
92 -Operating Range: 0 ~~ 96 %RH
93 -)))
52 +* Resolution: 0.04 %RH
53 +* Accuracy Tolerance : Typ ±3 %RH
54 +* Long Term Drift: < 0.02 °C/yr
55 +* Operating Range: 0 ~~ 96 %RH
94 94  
95 -(((
96 96  **External Temperature Sensor:**
97 -)))
98 98  
99 -* (((
100 -Resolution: 0.0625 °C
101 -)))
102 -* (((
103 -±0.5°C accuracy from -10°C to +85°C
104 -)))
105 -* (((
106 -±2°C accuracy from -55°C to +125°C
107 -)))
108 -* (((
109 -Operating Range: -55 °C ~~ 125 °C
110 -)))
59 +* Resolution: 0.0625 °C
60 +* ±0.5°C accuracy from -10°C to +85°C
61 +* ±2°C accuracy from -55°C to +125°C
62 +* Operating Range: -55 °C ~~ 125 °C
111 111  
112 112  = 2. Connect LHT65N to IoT Server =
113 113  
114 114  == 2.1 How does LHT65N work? ==
115 115  
116 -(((
117 117  LHT65N is configured as LoRaWAN OTAA Class A mode by default. Each LHT65N is shipped with a worldwide unique set of OTAA keys. To use LHT65N in a LoRaWAN network, first, we need to put the OTAA keys in LoRaWAN Network Server and then activate LHT65N.
118 -)))
119 119  
120 -(((
121 121  If LHT65N is under the coverage of this LoRaWAN network. LHT65N can join the LoRaWAN network automatically. After successfully joining, LHT65N will start to measure environment temperature and humidity, and start to transmit sensor data to the LoRaWAN server. The default period for each uplink is 20 minutes.
122 -)))
123 123  
72 +
124 124  == 2.2 How to Activate LHT65N? ==
125 125  
126 126  The LHT65N has two working modes:
... ... @@ -128,13 +128,15 @@
128 128  * **Deep Sleep Mode**: LHT65N doesn’t have any LoRaWAN activation. This mode is used for storage and shipping to save battery life.
129 129  * **Working Mode**: In this mode, LHT65N works as LoRaWAN Sensor mode to Join LoRaWAN network and send out the sensor data to the server. Between each sampling/tx/rx periodically, LHT65 will be in STOP mode (IDLE mode), in STOP mode, LHT65N has the same power consumption as Deep Sleep mode. 
130 130  
131 -(((
132 132  The LHT65N is set in deep sleep mode by default; The ACT button on the front is to switch to different modes:
133 -)))
134 134  
135 135  [[image:image-20220515123819-1.png||height="379" width="317"]]
136 136  
137 -[[image:image-20220523153201-19.png||height="180" width="818"]]
84 +(% border="1" %)
85 +|**Behavior on ACT**|**Function**|**Action**
86 +|**Pressing ACT between 1s < time < 3s**|Test uplink status|If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once.
87 +|**Pressing ACT for more than 3s**|Active Device|green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network.
88 +|**Fast press ACT 5 times**|Deactivate Device|red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode.
138 138  
139 139  == 2.3 Example to join LoRaWAN network ==
140 140  
... ... @@ -147,7 +147,7 @@
147 147  Assume the LPS8N is already set to connect to [[TTN V3 network>>url:https://eu1.cloud.thethings.network]], So it provides network coverage for LHT65N. Next we need to add the LHT65N device in TTN V3:
148 148  
149 149  
150 -=== 2.3.1 Step 1: Create Device n TTN ===
101 +=== **2.3.1 Step 1**: Create Device n TTN ===
151 151  
152 152  Create a device in TTN V3 with the OTAA keys from LHT65N.
153 153  
... ... @@ -161,8 +161,10 @@
161 161  
162 162  [[image:image-20220522232916-3.png]]
163 163  
115 +
164 164  [[image:image-20220522232932-4.png]]
165 165  
118 +
166 166  [[image:image-20220522232954-5.png]]
167 167  
168 168  Note: LHT65N use same payload as LHT65.
... ... @@ -179,56 +179,33 @@
179 179  
180 180  Use ACT button to activate LHT65N and it will auto-join to the TTN V3 network. After join success, it will start to upload sensor data to TTN V3 and user can see in the panel.
181 181  
182 -[[image:image-20220522233300-8.png||height="219" width="722"]]
135 +[[image:image-20220522233300-8.png]]
183 183  
184 184  
185 -== 2.4 Uplink Payload ==
138 +== Uplink Payload: ==
186 186  
187 -The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and (% style="color:#4f81bd" %)**every 20 minutes**(%%) send one uplink by default.
140 +The uplink payload includes totally 11 bytes. Uplink packets use FPORT=2 and(% class="mark" %) every 20 minutes(%%) send one uplink by default.
188 188  
189 -After each uplink, the (% style="color:blue" %)**BLUE LED**(%%) will blink once.
142 +After each uplink, the (% class="mark" %)BLUE LED(%%) will blink once.
190 190  
191 -(% border="1" style="background-color:#ffffcc; color:green; width:426px" %)
192 -|(% style="width:97px" %)(((
193 -**Size(bytes)**
194 -)))|(% style="width:39px" %)(((
195 -**2**
196 -)))|(% style="width:100px" %)(((
197 -**2**
198 -)))|(% style="width:77px" %)(((
199 -**2**
200 -)))|(% style="width:47px" %)(((
201 -**1**
202 -)))|(% style="width:51px" %)(((
203 -**4**
204 -)))
205 -|(% style="width:97px" %)(((
206 -**Value**
207 -)))|(% style="width:39px" %)(((
208 -[[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]]
209 -)))|(% style="width:100px" %)(((
210 -(((
211 -[[Built-In Temperature>>||anchor="#H2.4.3Built-inTemperature"]]
212 -)))
213 -)))|(% style="width:77px" %)(((
214 -(((
215 -[[Built-in>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
216 -)))
217 217  
218 -(((
219 -[[Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
220 -)))
221 -)))|(% style="width:47px" %)(((
222 -[[Ext>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.5Ext23]] #
223 -)))|(% style="width:51px" %)(((
224 -[[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]]
225 -)))
145 +(% style="width:572px" %)
146 +|(% style="width:106px" %)**Size(bytes)**|(% style="width:71px" %)**2**|(% style="width:128px" %)**2**|(% style="width:103px" %)**2**|(% style="width:72px" %)**1**|(% style="width:89px" %)**4**
147 +|(% style="width:106px" %)**Value**|(% style="width:71px" %)[[BAT>>path:#Battery]]|(% style="width:128px" %)(((
148 +[[Built-In>>path:#SHT20_Temperature]]
226 226  
150 +[[Temperature>>path:#SHT20_Temperature]]
151 +)))|(% style="width:103px" %)(((
152 +[[Built-in>>path:#SHT20_Humidity]]
153 +
154 +[[Humidity>>path:#SHT20_Humidity]]
155 +)))|(% style="width:72px" %)[[Ext>>path:#Extension_Sensor]] #|(% style="width:89px" %)[[Ext value>>path:#Extension_sensor_value]]
156 +
227 227  * The First 6 bytes: has fix meanings for every LHT65N.
228 228  * The 7th byte (EXT #): defines the external sensor model.
229 229  * The 8^^th^^ ~~ 11^^th^^ byte: the value for external sensor value. The definition is based on external sensor type. (If EXT=0, there won’t be these four bytes.)
230 230  
231 -=== 2.4.1 Decoder in TTN V3 ===
161 +=== Decoder in TTN V3 ===
232 232  
233 233  When the uplink payload arrives TTNv3, it shows HEX format and not friendly to read. We can add LHT65N decoder in TTNv3 for friendly reading.
234 234  
... ... @@ -236,24 +236,37 @@
236 236  
237 237  [[https:~~/~~/www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0 >>https://www.dropbox.com/sh/r2i3zlhsyrpavla/AAB1sZw3mdT0K7XjpHCITt13a?dl=0]]
238 238  
239 -[[image:image-20220522234118-10.png||height="353" width="729"]]
169 +[[image:image-20220522234118-10.png]]
240 240  
241 -=== 2.4.2 BAT-Battery Info ===
242 242  
172 +=== BAT-Battery Info ===
173 +
243 243  These two bytes of BAT include the battery state and the actually voltage
244 244  
245 -[[image:image-20220523152839-18.png]]
176 +(% style="width:646px" %)
177 +|Bit(bit)|(% style="width:272px" %)[15:14]|(% style="width:214px" %)[13:0]
178 +|Value|(% style="width:272px" %)(((
179 +BAT Status
246 246  
247 -[[image:image-20220522235639-1.png||height="139" width="727"]]
181 +00(b): Ultra Low ( BAT <= 2.50v)
248 248  
183 +01(b): Low  (2.50v <=BAT <= 2.55v)
184 +
185 +10(b): OK   (2.55v <= BAT <=2.65v)
186 +
187 +11(b): Good   (BAT >= 2.65v)
188 +)))|(% style="width:214px" %)Actually BAT voltage
189 +
190 +[[image:image-20220522235639-1.png]]
191 +
249 249  Check the battery voltage for LHT65N.
250 250  
251 251  * BAT status=(0Xcba4>>14)&0xFF=11(B),very good
252 252  * Battery Voltage =0xCBF6&0x3FFF=0x0BA4=2980mV
253 253  
254 -=== 2.4.3 Built-in Temperature ===
197 +=== Built-in Temperature ===
255 255  
256 -[[image:image-20220522235639-2.png||height="138" width="722"]]
199 +[[image:image-20220522235639-2.png]]
257 257  
258 258  * Temperature:  0x0ABB/100=27.47℃
259 259  
... ... @@ -261,92 +261,72 @@
261 261  
262 262  * Temperature:  (0xF5C6-65536)/100=-26.18℃
263 263  
264 -=== 2.4.4 Built-in Humidity ===
207 +=== Built-in Humidity ===
265 265  
266 -[[image:image-20220522235639-4.png||height="138" width="722"]]
209 +[[image:image-20220522235639-4.png]]
267 267  
268 268  * Humidity:    0x025C/10=60.4%
269 269  
270 -=== 2.4.5 Ext # ===
213 +=== Ext # ===
271 271  
272 272  Bytes for External Sensor:
273 273  
274 -[[image:image-20220523152822-17.png]]
217 +(% style="width:624px" %)
218 +|(% style="width:139px" %)**EXT # Value**|(% style="width:484px" %)**External Sensor Type**
219 +|(% style="width:139px" %)0x01|(% style="width:484px" %)Sensor E3, Temperature Sensor
220 +|(% style="width:139px" %)0x09|(% style="width:484px" %)Sensor E3, Temperature Sensor, Datalog Mod
275 275  
276 -=== 2.4.6 Ext value ===
222 +=== Ext value ===
277 277  
278 -==== 2.4.6.1 Ext~=1, E3 Temperature Sensor ====
224 +==== Ext~=1, E3 Temperature Sensor ====
279 279  
280 280  [[image:image-20220522235639-5.png]]
281 281  
228 +
282 282  * DS18B20 temp=0x0ADD/100=27.81℃
283 283  
284 284  The last 2 bytes of data are meaningless
285 285  
233 +
234 +
286 286  [[image:image-20220522235639-6.png]]
287 287  
288 288  * External temperature= (0xF54F-65536)/100=-27.37℃
289 289  
290 -(((
291 291  The last 2 bytes of data are meaningless
292 -)))
293 293  
294 -(((
241 +
295 295  If the external sensor is 0x01, and there is no external temperature connected. The temperature will be set to 7FFF which is 327.67℃
296 -)))
297 297  
298 298  
299 -==== 2.4.6.2 Ext~=9, E3 sensor with Unix Timestamp ====
245 +==== Ext~=9, E3 sensor with Unix Timestamp ====
300 300  
301 301  Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below:
302 302  
303 -(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
304 -|(% style="width:96px" %)(((
305 -**Size(bytes)**
306 -)))|(% style="width:71px" %)(((
307 -**2**
308 -)))|(% style="width:99px" %)(((
309 -**2**
310 -)))|(% style="width:132px" %)(((
311 -**2**
312 -)))|(% style="width:54px" %)(((
313 -**1**
314 -)))|(% style="width:64px" %)(((
315 -**4**
316 -)))
317 -|(% style="width:96px" %)(((
318 -**Value**
319 -)))|(% style="width:71px" %)(((
320 -[[External temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.2SetExternalSensorMode]]
321 -)))|(% style="width:99px" %)(((
322 -(((
323 -[[Built-In>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
324 -)))
325 325  
326 -(((
327 -[[Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
328 -)))
329 -)))|(% style="width:132px" %)(((
330 -(((
331 -BAT Status &
332 -)))
250 +(% style="width:697px" %)
251 +|(% style="width:96px" %)**Size(bytes)**|(% style="width:164px" %)**2**|(% style="width:104px" %)**2**|(% style="width:106px" %)**2**|(% style="width:108px" %)**1**|(% style="width:116px" %)**4**
252 +|(% style="width:96px" %)**Value**|(% style="width:164px" %)[[External temperature>>path:#DS18b20_value]]|(% style="width:104px" %)(((
253 +[[Built-In>>path:#SHT20_Temperature]]
333 333  
334 -(((
335 -[[Built-in Humidity>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
255 +[[Temperature>>path:#SHT20_Temperature]]
256 +)))|(% style="width:106px" %)(((
257 +[[BAT Status &>>path:#BAT_Humidity]]
258 +
259 +[[Built-in>>path:#BAT_Humidity]]
260 +
261 +[[Humidity>>path:#BAT_Humidity]]
262 +)))|(% style="width:108px" %)[[Status & Ext>>path:#Status_EXT]]|(% style="width:116px" %)(((
263 +[[Unix>>path:#Unix_Time_Stamp]]
264 +
265 +[[Time Stamp>>path:#Unix_Time_Stamp]]
336 336  )))
337 -)))|(% style="width:54px" %)(((
338 -Status & Ext
339 -)))|(% style="width:64px" %)(((
340 -(((
341 -[[Unix Time Stamp>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H4.1SetTransmitIntervalTime]]
342 -)))
343 -)))
344 344  
345 -* **Battery status & (% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)Built-in Humidity(%%)**
268 +* **Battery status & **[[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)**Built-in Humidity**>>path:#SHT20_Humidity]]
346 346  
347 -(% border="1" style="background-color:#ffffcc; color:green; width:469px" %)
348 -|(% style="width:65px" %)Bit(bit)|(% style="width:267px" %)[15:14]|(% style="width:134px" %)[11:0]
349 -|(% style="width:65px" %)Value|(% style="width:267px" %)(((
270 +(% style="width:587px" %)
271 +|Bit(bit)|(% style="width:280px" %)[15:14]|(% style="width:136px" %)[11:0]
272 +|Value|(% style="width:280px" %)(((
350 350  BAT Status
351 351  
352 352  00(b): Ultra Low ( BAT <= 2.50v)
... ... @@ -356,8 +356,8 @@
356 356  10(b): OK   (2.55v <= BAT <=2.65v)
357 357  
358 358  11(b): Good   (BAT >= 2.65v)
359 -)))|(% style="width:134px" %)(((
360 -[[Built-in Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
282 +)))|(% style="width:136px" %)(((
283 +[[Built-in Humidity>>path:#SHT20_Humidity]]
361 361  
362 362  
363 363  )))
... ... @@ -364,27 +364,29 @@
364 364  
365 365  * **Status & Ext Byte**
366 366  
367 -[[image:image-20220523152434-16.png]]
290 +(% style="width:732px" %)
291 +|(% style="width:128px" %)**Bits**|(% style="width:102px" %)**7**|(% style="width:145px" %)**6**|(% style="width:117px" %)**5**|(% style="width:147px" %)**4**|(% style="width:90px" %)**[3:0]**
292 +|(% style="width:128px" %)**Status & Ext**|(% style="width:102px" %)Not Defined|(% style="width:145px" %)Poll Message Flag|(% style="width:117px" %)Sync time OK|(% style="width:147px" %)Unix Time Request|(% style="width:90px" %)(((
293 +Ext:
368 368  
295 +0b(1001)
296 +)))
297 +
369 369  * Poll Message Flag: 1: This message is a poll message reply, 0: means this is a normal uplink.
370 370  * Sync time OK: 1: Set time ok,0: N/A. After time SYNC request is sent, LHT65N will set this bit to 0 until got the time stamp from the application server.
371 371  * Unix Time Request:1: Request server downlink Unix time, 0 : N/A. In this mode, LHT65N will set this bit to 1 every 10 days to request a time SYNC. (AT+SYNCMOD to set this)
372 372  
373 -== 2.5 Show data on Datacake ==
302 +== Show data on Datacake ==
374 374  
375 375  Datacake IoT platform provides a human-friendly interface to show the sensor data, once we have sensor data in TTN V3, we can use Datacake to connect to TTN V3 and see the data in Datacake. Below are the steps:
376 376  
377 -(((
306 +
378 378  **Step 1**: Be sure that your device is programmed and properly connected to the LoRaWAN network.
379 -)))
380 380  
381 -(((
382 382  **Step 2**: Configure your Application to forward data to Datacake you will need to add integration. Go to TTN V3 Console ~-~-> Applications ~-~-> Integrations ~-~-> Add Integrations.
383 -)))
384 384  
385 -(((
311 +
386 386  Add Datacake:
387 -)))
388 388  
389 389  [[image:image-20220523000825-7.png||height="262" width="583"]]
390 390  
... ... @@ -393,24 +393,21 @@
393 393  
394 394  [[image:image-20220523000825-8.png||height="453" width="406"]]
395 395  
321 +
396 396  In Datacake console ([[https:~~/~~/datacake.co/>>url:https://datacake.co/]]) , add LHT65 device.
397 397  
398 398  [[image:image-20220523000825-9.png||height="366" width="392"]]
399 399  
400 -[[image:image-20220523000825-10.png||height="413" width="728"]]
401 401  
402 -== 2.6 Datalog Feature ==
403 403  
404 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, LHT65N will store the reading for future retrieving purposes. There are two ways for IoT servers to get datalog from LHT65N.
328 +[[image:image-20220523000825-10.png||height="432" width="762"]]
405 405  
406 -=== 2.6.1 Ways to get datalog via LoRaWAN ===
407 407  
408 -There are two methods:
331 +== Datalog Feature ==
409 409  
410 -1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
411 -1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
333 +This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
412 412  
413 -=== 2.6.2 Unix TimeStamp ===
335 +=== Unix TimeStamp ===
414 414  
415 415  LHT65N uses Unix TimeStamp format based on
416 416  
... ... @@ -417,215 +417,100 @@
417 417  [[image:image-20220523001219-11.png||height="97" width="627"]]
418 418  
419 419  
420 -(((
421 421  User can get this time from link:  [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] :
422 -)))
423 423  
424 -(((
425 425  Below is the converter example
426 -)))
427 427  
428 -[[image:image-20220523001219-12.png||height="298" width="720"]]
346 +[[image:image-20220523001219-12.png||height="353" width="853"]]
429 429  
430 430  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
431 431  
432 -=== 2.6.3 Set Device Time ===
433 433  
434 -(((
351 +=== Set Device Time ===
352 +
435 435  There are two ways to set device’s time:
436 -)))
437 437  
438 -(((
439 439  **~1. Through LoRaWAN MAC Command (Default settings)**
440 -)))
441 441  
442 -(((
443 443  User need to set SYNCMOD=1 to enable sync time via MAC command.
444 -)))
445 445  
446 -(((
447 447  Once LHT65N Joined LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to LHT65N. If LHT65N fails to get the time from the server, LHT65N will use the internal time and wait for next time request (AT+SYNCTDC to set the time request period, default is 10 days).
448 -)))
449 449  
450 -(((
451 451  Note: LoRaWAN Server need to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature, Chirpstack,TTN V3 v3 and loriot support but TTN V3 v2 doesn’t support. If server doesn’t support this command, it will through away uplink packet with this command, so user will lose the packet with time request for TTN V3 v2 if SYNCMOD=1.
452 -)))
453 453  
454 -(((
455 -
456 -)))
457 457  
458 -(((
459 459  **2. Manually Set Time**
460 -)))
461 461  
462 -(((
463 463  User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
464 -)))
465 465  
466 -=== 2.6.4 Poll sensor value ===
467 467  
369 +=== Poll sensor value ===
370 +
468 468  User can poll sensor value based on timestamps from the server. Below is the downlink command.
469 469  
470 -[[image:image-20220523152302-15.png]]
471 471  
472 -(((
374 +(% style="width:454px" %)
375 +|(% style="width:69px" %)1byte|(% style="width:129px" %)4bytes|(% style="width:134px" %)4bytes|(% style="width:119px" %)1byte
376 +|(% style="width:69px" %)31|(% style="width:129px" %)Timestamp start|(% style="width:134px" %)Timestamp end|(% style="width:119px" %)Uplink Interval
377 +
473 473  Timestamp start and Timestamp end use Unix TimeStamp format as mentioned above. Devices will reply with all data log during this time period, use the uplink interval.
474 -)))
475 475  
476 -(((
477 -For example, downlink command (% style="display:none" %) (%%)**31 5FC5F350 5FC6 0160 05**
478 -)))
479 479  
480 -(((
381 +For example, downlink command 31 5FC5F350 5FC6 0160 05
382 +
481 481  Is to check 2020/12/1 07:40:00 to 2020/12/1 08:40:00’s data
482 -)))
483 483  
484 -(((
485 485  Uplink Internal =5s,means LHT65N will send one packet every 5s. range 5~~255s.
486 -)))
487 487  
488 488  
489 -=== 2.6.5 Datalog Uplink payload ===
388 +=== Datalog Uplink payload ===
490 490  
491 491  The Datalog poll reply uplink will use below payload format.
492 492  
493 -(((
494 -**Retrieval data payload**
495 -)))
496 496  
497 -(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
498 -|(% style="width:93px" %)(((
499 -(((
500 -**Size(bytes)**
501 -)))
502 -)))|(% style="width:71px" %)(((
503 -(((
504 -**2**
505 -)))
506 -)))|(% style="width:102px" %)(((
507 -(((
508 -**2**
509 -)))
510 -)))|(% style="width:86px" %)(((
511 -(((
512 -**2**
513 -)))
514 -)))|(% style="width:86px" %)(((
515 -(((
516 -**1**
517 -)))
518 -)))|(% style="width:48px" %)(((
519 -(((
520 -**4**
521 -)))
522 -)))
523 -|(% style="width:93px" %)(((
524 -(((
525 -**Value**
526 -)))
527 -)))|(% style="width:71px" %)(((
528 -(((
529 -[[External sensor data>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]]
530 -)))
531 -)))|(% style="width:102px" %)(((
532 -(((
533 -(((
534 -[[Built In>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
535 -)))
536 -)))
393 +Retrieval data payload
537 537  
538 -(((
539 -(((
540 -[[Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
541 -)))
542 -)))
543 -)))|(% style="width:86px" %)(((
544 -(((
545 -(((
546 -[[Built-in>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
547 -)))
548 -)))
395 +|**Size(bytes)**|**2**|**2**|**2**|**1**|**4**
396 +|**Value**|[[External sensor data>>path:#Extension_sensor_value]]|(((
397 +[[Built-In>>path:#SHT20_Temperature]]
549 549  
550 -(((
551 -(((
552 -[[Humidity>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
553 -)))
554 -)))
555 -)))|(% style="width:86px" %)(((
556 -(((
557 -[[Poll message flag & Ext>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.6.4DatalogUplinkpayload]]
558 -)))
559 -)))|(% style="width:48px" %)(((
560 -(((
561 -(((
562 -[[Unix Time Stamp>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.6.1UnixTimeStamp]]
563 -)))
564 -)))
399 +[[Temperature>>path:#SHT20_Temperature]]
400 +)))|(((
401 +[[Built-in>>path:#SHT20_Humidity]]
565 565  
566 -(((
567 -(((
403 +[[Humidity>>path:#SHT20_Humidity]]
404 +)))|[[Poll message flag & Ext>>path:#Poll_EXT]]|(((
405 +[[Unix Time Stamp>>path:#Unix_Time_Stamp]]
406 +
568 568  
569 569  )))
570 -)))
571 -)))
572 572  
573 -**Poll message flag & Ext**
410 +Poll message flag & Ext
574 574  
575 -[[image:image-20220523152208-14.png]]
576 576  
577 -(((
578 -(((
579 -Poll Message Flag: 1: This message is a poll message reply.
580 -)))
581 -)))
413 +|**Bits**|**7**|**6**|**5**|**4**|**[3:0]**
414 +|**Status & Ext**|Not Defined|Poll Message Flag|Sync time OK|Unix Time Request|(((
415 +Ext:
582 582  
583 -* (((
584 -(((
585 -Poll Message Flag is set to 1.
417 +0b(1001)
586 586  )))
587 -)))
588 -* (((
589 -(((
590 -Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands.
591 -)))
592 -)))
593 593  
594 -(((
595 -(((
420 +Poll Message Flag: 1: This message is a poll message reply.
421 +
422 +* Poll Message Flag is set to 1.
423 +* Each data entry is 11 bytes, to save airtime and battery, devices will send max bytes according to the current DR and Frequency bands.
424 +
596 596  For example, in US915 band, the max payload for different DR is:
597 -)))
598 -)))
599 599  
600 -(((
601 -(((
602 -a) DR0: max is 11 bytes so one entry of data
603 -)))
604 -)))
427 +a)      DR0: max is 11 bytes so one entry of data
605 605  
606 -(((
607 -(((
608 -b) DR1: max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
609 -)))
610 -)))
429 +b)      DR1: max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
611 611  
612 -(((
613 -(((
614 -c) DR2: total payload includes 11 entries of data
615 -)))
616 -)))
431 +c)      DR2: total payload includes 11 entries of data
617 617  
618 -(((
619 -(((
620 -d) DR3: total payload includes 22 entries of data.
621 -)))
622 -)))
433 +d)      DR3: total payload includes 22 entries of data.
623 623  
624 -(((
625 -(((
626 626  If devise doesn’t have any data in the polling time. Device will uplink 11 bytes of 0   
627 -)))
628 -)))
629 629  
630 630  
631 631  **Example:**
... ... @@ -632,29 +632,37 @@
632 632  
633 633  If LHT65N has below data inside Flash:
634 634  
635 -[[image:image-20220523144455-1.png||height="335" width="735"]]
442 +Flash Addr   |Unix Time | Ext | BAT voltage|  Value                  
636 636  
637 -(((
638 -If user sends below downlink command: (% style="background-color:yellow" %)3160065F9760066DA705
639 -)))
444 +80196E0 21/1/19 04:27:03 1 3145 sht_temp=22.00 sht_hum=32.6 ds_temp=327.67
640 640  
641 -(((
446 +80196F0 21/1/19 04:28:57 1 3145 sht_temp=21.90 sht_hum=33.1 ds_temp=327.67
447 +
448 +8019700 21/1/19 04:30:30 1 3145 sht_temp=21.81 sht_hum=33.4 ds_temp=327.67
449 +
450 +8019710 21/1/19 04:40:30 1 3145 sht_temp=21.65 sht_hum=33.7 ds_temp=327.67
451 +
452 +8019720 21/1/19 04:50:30 1 3147 sht_temp=21.55 sht_hum=34.1 ds_temp=327.67
453 +
454 +8019730 21/1/19 05:00:30 1 3149 sht_temp=21.50 sht_hum=34.1 ds_temp=327.67
455 +
456 +8019740 21/1/19 05:10:30 1 3149 sht_temp=21.43 sht_hum=34.6 ds_temp=327.67
457 +
458 +8019750 21/1/19 05:20:30 1 3151 sht_temp=21.35 sht_hum=34.9 ds_temp=327.67
459 +
460 +
461 +If user sends below downlink command:
462 +
463 +3160065F9760066DA705
464 +
642 642   Where : Start time: 60065F97 = time 21/1/19 04:27:03
643 -)))
644 644  
645 -(((
646 646   Stop time 60066DA7= time 21/1/19 05:27:03
647 -)))
648 648  
649 -(((
650 -
651 -)))
652 652  
653 -(((
654 654  LHT65N will uplink this payload.
655 -)))
656 656  
657 -[[image:image-20220523001219-13.png||height="421" width="727"]]
472 +[[image:image-20220523001219-13.png]]
658 658  
659 659  7FFF089801464160065F977FFF088E014B41600660097FFF0885014E41600660667FFF0875015141600662BE7FFF086B015541600665167FFF08660155416006676E7FFF085F015A41600669C67FFF0857015D4160066C1E
660 660  
... ... @@ -672,69 +672,49 @@
672 672  
673 673  Unix time is 0x60065F97=1611030423s=21/1/19 04:27:03
674 674  
675 -== 2.7 Alarm Mode ==
676 676  
491 +== Alarm Mode ==
492 +
677 677  Alarm mode feature is added since firmware v1.5. When device is in Alarm mode, it will check the built-in sensor temperature in a short interval. If the temperature exceeds the pre-configure range, it will send an uplink immediately.
678 678  
679 -(((
680 -(% style="color:red" %)Note: Alarm mode will increase a little big the power consumption, we recommend extending the normal reading time when enabling this feature.
681 -)))
682 682  
683 -(((
684 -**AT Commands for Alarm mode:**
685 -)))
496 +Note: Alarm mode will increase a little big the power consumption, we recommend extending the normal reading time when enabling this feature.
686 686  
687 -(% class="box infomessage" %)
688 -(((
689 -(((
498 +
499 +AT Commands for Alarm mode:
500 +
690 690  **AT+WMOD=1**: Enable/Disable Alarm Mode. (0:Disable, 1: Enable)
691 -)))
692 -)))
693 693  
694 -(% class="box infomessage" %)
695 -(((
696 -(((
697 697  **AT+CITEMP=1**: The interval to check the temperature for Alarm. (Unit: minute)
698 -)))
699 -)))
700 700  
701 -== 2.8 LED Indicator ==
702 702  
703 -(((
506 +
507 +== LED Indicator ==
508 +
704 704  The LHT65N has a triple color LED which for easy shows different stage.
705 -)))
706 706  
707 -(((
708 708  While pressing ACT button, the LED will work as per LED status with ACT button.
709 -)))
710 710  
711 -(((
712 712  In a normal working state:
713 -)))
714 714  
715 -* (((
716 -For each uplink, the BLUE LED or RED LED will blink once.
717 -)))
718 -* (((
719 -BLUE LED when an external sensor is connected
720 -)))
721 -* (((
722 -RED LED when an external sensor is not connected
723 -)))
724 -* (((
725 -For each success downlink, the PURPLE LED will blink once
726 -)))
515 +* For each uplink, the BLUE LED or RED LED will blink once.
516 +* BLUE LED when an external sensor is connected
517 +* RED LED when an external sensor is not connected
518 +* For each success downlink, the PURPLE LED will blink once
727 727  
728 728  ----
729 729  
730 -== 2.9 Installation ==
522 +== Installation ==
731 731  
732 732  [[image:image-20220516231650-1.png||height="436" width="428"]]
733 733  
734 -= 3. Sensors & Accessories =
735 735  
736 -== 3.1 E3 Temperature Probe ==
737 737  
528 +
529 += Sensors & Accessories =
530 +
531 +== E3 Temperature Probe ==
532 +
738 738  [[image:image-20220515080154-4.png||height="182" width="161"]] [[image:image-20220515080330-5.png||height="201" width="195"]]
739 739  
740 740  
... ... @@ -747,116 +747,93 @@
747 747  * -55°C to 125°C
748 748  * Working voltage 2.35v ~~ 5v
749 749  
750 -= 4. Configure LHT65N via AT Command or LoRaWAN Downlink =
545 += Configure LHT65N via AT Command or LoRaWAN Downlink =
751 751  
752 -(((
753 753  Use can configure LHT65N via AT Command or LoRaWAN Downlink.
754 -)))
755 755  
756 -* (((
757 -AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
758 -)))
759 -* (((
760 -LoRaWAN Downlink instruction for different platforms:
761 -)))
549 +* AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
550 +* LoRaWAN Downlink instruction for different platforms:
762 762  
763 -(((
764 764  [[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
765 -)))
766 766  
767 -(((
554 +
768 768  There are two kinds of commands to configure LHT65N, they are:
769 -)))
770 770  
771 -(((
772 -(% style="color:#4f81bd" %)* **General Commands**.
773 -)))
557 +* **General Commands**.
774 774  
775 -(((
776 776  These commands are to configure:
777 -)))
778 778  
779 -* (((
780 -General system settings like: uplink interval.
781 -)))
782 -* (((
783 -LoRaWAN protocol & radio-related commands.
784 -)))
561 +* General system settings like: uplink interval.
562 +* LoRaWAN protocol & radio-related commands.
785 785  
786 -(((
787 787  They are the same for all Dragino Devices which supports DLWS-005 LoRaWAN Stack(Note~*~*). These commands can be found on the wiki:
788 -)))
789 789  
790 -(((
791 791  [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
792 -)))
793 793  
794 -(((
795 -(% style="color:#4f81bd" %)* **Commands special design for LHT65N**
796 -)))
797 797  
798 -(((
569 +
570 +* **Commands special design for LHT65N**
571 +
799 799  These commands are only valid for LHT65N, as below:
800 -)))
801 801  
802 -== 4.1 Set Transmit Interval Time ==
803 803  
575 +== Set Transmit Interval Time ==
576 +
804 804  Feature: Change LoRaWAN End Node Transmit Interval.
805 805  
806 806  **AT Command: AT+TDC**
807 807  
808 -[[image:image-20220523150701-2.png]]
581 +|**Command Example**|**Function**|**Response**
582 +|AT+TDC?|Show current transmit Interval|(((
583 +30000
809 809  
810 -(((
811 -**Downlink Command: 0x01**
585 +OK
586 +
587 +the interval is 30000ms = 30s
812 812  )))
589 +|AT+TDC=60000|Set Transmit Interval|(((
590 +OK
813 813  
814 -(((
815 -Format: Command Code (0x01) followed by 3 bytes time value.
592 +Set transmit interval to 60000ms = 60 seconds
816 816  )))
817 817  
818 -(((
595 +**Downlink Command: 0x01**
596 +
597 +Format: Command Code (0x01) followed by 3 bytes time value.
598 +
819 819  If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
820 -)))
821 821  
822 -* (((
823 -**Example 1**: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
824 -)))
825 -* (((
826 -**Example 2**: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
827 -)))
601 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
602 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
828 828  
829 -== 4.2 Set External Sensor Mode ==
604 +== Set External Sensor Mode ==
830 830  
831 831  Feature: Change External Sensor Mode.
832 832  
833 833  **AT Command: AT+EXT**
834 834  
835 -[[image:image-20220523150759-3.png]]
610 +|**Command Example**|**Function**|**Response**
611 +|AT+EXT?|Get current external sensor mode|(((
612 +1
836 836  
837 -(((
838 -**Downlink Command: 0xA2**
614 +OK
615 +
616 +External Sensor mode =1
839 839  )))
618 +|AT+EXT=1|(% colspan="2" %)Set external sensor mode to 1
619 +|AT+EXT=9|(% colspan="2" %)Set to external DS18B20 with timestamp
840 840  
841 -(((
621 +**Downlink Command: 0xA2**
622 +
842 842  Total bytes: 2 ~~ 5 bytes
843 -)))
844 844  
845 -(((
846 -**Example:**
847 -)))
625 +Example:
848 848  
849 -* (((
850 -0xA201: Set external sensor type to E1
851 -)))
852 -* (((
853 -0xA209: Same as AT+EXT=9
854 -)))
855 -* (((
856 -0xA20702003c,Same as AT+SETCNT=60
857 -)))
627 +* 0xA201: Set external sensor type to E1
628 +* 0xA209: Same as AT+EXT=9
629 +* 0xA20702003c,Same as AT+SETCNT=60
858 858  
859 -== 4.3 Enable/Disable uplink Temperature probe ID ==
631 +== Enable/Disable uplink Temperature probe ID ==
860 860  
861 861  Feature: If PID is enabled, device will send the temperature probe ID on:
862 862  
... ... @@ -865,82 +865,99 @@
865 865  
866 866  PID is default set to disable (0)
867 867  
640 +
868 868  **AT Command:**
869 869  
870 -[[image:image-20220523150928-4.png]]
643 +|**Command Example**|**Function**|**Response**
644 +|AT+PID=1|Enable PID uplink|OK
871 871  
872 872  **Downlink Command:**
873 873  
874 -* 0xA800  **~-~->** AT+PID=0
875 -* 0xA801     **~-~->** AT+PID=1
648 +* 0xA800     à AT+PID=0
649 +* 0xA801     à AT+PID=1
876 876  
877 -== 4.4 Set Password ==
651 +== Set Password ==
878 878  
879 879  Feature: Set device password, max 9 digits
880 880  
881 881  **AT Command: AT+PWORD**
882 882  
883 -[[image:image-20220523151052-5.png]]
657 +|**Command Example**|**Function**|**Response**
658 +|AT+PWORD=?|Show password|(((
659 +123456
884 884  
885 -(((
886 -**Downlink Command:**
661 +
662 +OK
887 887  )))
664 +|AT+PWORD=999999|Set password|OK
888 888  
889 -(((
666 +**Downlink Command:**
667 +
890 890  No downlink command for this feature.
891 -)))
892 892  
893 -== 4.5 Quit AT Command ==
894 894  
671 +== Quit AT Command ==
672 +
895 895  Feature: Quit AT Command mode, so user needs to input password again before use AT Commands.
896 896  
897 897  **AT Command: AT+DISAT**
898 898  
899 -[[image:image-20220523151132-6.png]]
677 +|**Command Example**|**Function**|**Response**
678 +|AT+DISAT|Quit AT Commands mode|OK
900 900  
901 901  **Downlink Command:**
902 902  
903 903  No downlink command for this feature.
904 904  
905 -== 4.6 Set to sleep mode ==
906 906  
685 +== Set to sleep mode ==
686 +
907 907  Feature: Set device to sleep mode
908 908  
909 909  **AT Command: AT+SLEEP**
910 910  
911 -[[image:image-20220523151218-7.png]]
691 +| | |
692 +|**Command Example**|**Function**|**Response**
693 +|AT+SLEEP|Set to sleep mode|(((
694 +Clear all stored sensor data…
912 912  
696 +OK
697 +)))
698 +
913 913  **Downlink Command:**
914 914  
915 915  * There is no downlink command to set to Sleep mode.
916 916  
917 -== 4.7 Set system time ==
703 +== Set system time ==
918 918  
919 919  Feature: Set system time, unix format. [[See here for format detail.>>path:#TimeStamp]]
920 920  
921 921  **AT Command:**
922 922  
923 -[[image:image-20220523151253-8.png]]
709 +|**Command Example**|**Function**
710 +|AT+TIMESTAMP=1611104352|(((
711 +OK
924 924  
713 +Set System time to 2021-01-20 00:59:12
714 +)))
715 +
925 925  **Downlink Command:**
926 926  
927 927  0x306007806000 ~/~/ Set timestamp to 0x(6007806000),Same as AT+TIMESTAMP=1611104352
928 928  
929 -== 4.8 Set Time Sync Mode ==
930 930  
931 -(((
721 +== Set Time Sync Mode ==
722 +
932 932  Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply this command.
933 -)))
934 934  
935 -(((
725 +
936 936  SYNCMOD is set to 1 by default. If user want to set a different time from LoRaWAN server, user need to set this to 0.
937 -)))
938 938  
939 -(((
728 +
940 940  **AT Command:**
941 -)))
942 942  
943 -[[image:image-20220523151336-9.png]]
731 +|**Command Example**|**Function**
732 +|AT+SYNCMOD=1|Enable Sync system time via LoRaWAN MAC Command (DeviceTimeReq)
944 944  
945 945  **Downlink Command:**
946 946  
... ... @@ -948,185 +948,196 @@
948 948  
949 949  0x28 00 ~/~/ Same As AT+SYNCMOD=0
950 950  
951 -== 4.9 Set Time Sync Interval ==
952 952  
741 +== Set Time Sync Interval ==
742 +
953 953  Feature: Define System time sync interval. SYNCTDC default value: 10 days.
954 954  
955 955  **AT Command:**
956 956  
957 -[[image:image-20220523151411-10.png]]
747 +|**Command Example**|**Function**
748 +|AT+SYNCTDC=0x0A|Set SYNCTDC to 10 (0x0A), so the sync time is 10 days.
958 958  
959 959  **Downlink Command:**
960 960  
961 961  0x29 0A ~/~/ Same as AT+SYNCTDC=0x0A
962 962  
963 -== 4.10 Print data entries base on page. ==
964 964  
755 +== Print data entries base on page. ==
756 +
965 965  Feature: Print the sector data from start page to stop page (max is 416 pages).
966 966  
967 967  **AT Command: AT+PDTA**
968 968  
969 -[[image:image-20220523151450-11.png]]
761 +|**Command Example**|**Response**
762 +|(((
763 +AT+PDTA=1,3
970 970  
765 +
766 +
767 +Print page 1 to 3
768 +)))|(((
769 +8019500 19/6/26 16:48 1 2992 sht_temp=28.21 sht_hum=71.5 ds_temp=27.31
770 +
771 +8019510 19/6/26 16:53 1 2994 sht_temp=27.64 sht_hum=69.3 ds_temp=26.93
772 +
773 +8019520 19/6/26 16:58 1 2996 sht_temp=28.39 sht_hum=72.0 ds_temp=27.06
774 +
775 +8019530 19/6/26 17:03 1 2996 sht_temp=27.97 sht_hum=70.4 ds_temp=27.12
776 +
777 +8019540 19/6/26 17:08 1 2996 sht_temp=27.80 sht_hum=72.9 ds_temp=27.06
778 +
779 +8019550 19/6/26 17:13 1 2998 sht_temp=27.30 sht_hum=72.4 ds_temp=26.68
780 +
781 +8019560 19/6/26 17:22 1 2992 sht_temp=26.27 sht_hum=62.3 ds_temp=26.56
782 +
783 +8019570
784 +
785 +8019580
786 +
787 +8019590
788 +
789 +80195A0
790 +
791 +80195B0
792 +
793 +80195C0
794 +
795 +80195D0
796 +
797 +80195E0
798 +
799 +80195F0
800 +
801 +
802 +OK
803 +)))
804 +
971 971  **Downlink Command:**
972 972  
973 973  No downlink commands for feature
974 974  
975 -== 4.11 Print last few data entries. ==
976 976  
810 +
811 +== Print last few data entries. ==
812 +
977 977  Feature: Print the last few data entries
978 978  
979 979  **AT Command: AT+PLDTA**
980 980  
981 -[[image:image-20220523151524-12.png]]
817 +|**Command Example**|**Response**
818 +|(((
819 +AT+PLDTA=5
982 982  
983 -**Downlink Command:**
984 984  
985 -No downlink commands for feature
986 986  
987 -== 4.12 Clear Flash Record ==
823 +Print last 5 entries
824 +)))|(((
825 +Stop Tx and RTP events when read sensor data
988 988  
989 -Feature: Clear flash storage for data log feature.
827 +1 19/6/26 13:59 1 3005 sht_temp=27.09 sht_hum=79.5 ds_temp=26.75
990 990  
991 -**AT Command: AT+CLRDTA**
829 +2 19/6/26 14:04 1 3007 sht_temp=26.65 sht_hum=74.8 ds_temp=26.43
992 992  
993 -[[image:image-20220523151556-13.png]]
831 +3 19/6/26 14:09 1 3007 sht_temp=26.91 sht_hum=77.9 ds_temp=26.56
994 994  
995 -**Downlink Command: 0xA3**
833 +4 19/6/26 14:15 1 3007 sht_temp=26.93 sht_hum=76.7 ds_temp=26.75
996 996  
997 -* Example: 0xA301 ~/~/Same as AT+CLRDTA
835 +5 19/6/26 14:20 1 3007 sht_temp=26.78 sht_hum=76.6 ds_temp=26.43
998 998  
999 -== 4.13 Auto Send None-ACK messages ==
837 +Start Tx and RTP events
1000 1000  
1001 -Feature: LHT65N will wait for ACK for each uplink, If LHT65N doesn't get ACK from the IoT server, it will consider the message doesn't arrive server and store it. LHT65N keeps sending messages in normal periodically. Once LHT65N gets ACK from a server, it will consider the network is ok and start to send the not-arrive message.
839 +OK
840 +)))
1002 1002  
842 +**Downlink Command:**
1003 1003  
1004 -**AT Command: AT+PNACKMD**
844 +No downlink commands for feature
1005 1005  
1006 -The default factory setting is 0
1007 1007  
847 +
848 +== Clear Flash Record ==
849 +
850 +Feature: Clear flash storage for data log feature.
851 +
852 +**AT Command: AT+CLRDTA**
853 +
1008 1008  |**Command Example**|**Function**|**Response**
1009 -|AT+PNACKMD=1|Poll None-ACK message|OK
855 +|AT+CLRDTA|Clear date record|(((
856 +Clear all stored sensor data…
1010 1010  
1011 -**Downlink Command: 0x34**
858 +OK
859 +)))
1012 1012  
1013 -* Example: 0x3401 ~/~/Same as AT+PNACKMD=1
861 +**Downlink Command: 0xA3**
1014 1014  
1015 -= 5. Battery & How to replace =
863 +* Example: 0xA301 ~/~/Same as AT+CLRDTA
1016 1016  
1017 -== 5.1 Battery Type ==
1018 1018  
866 += Battery & How to replace =
867 +
868 +== Battery Type ==
869 +
1019 1019  LHT65N is equipped with a 2400mAH Li-MnO2 (CR17505) battery . The battery is an un-rechargeable battery with low discharge rate targeting for up to 8~~10 years use. This type of battery is commonly used in IoT devices for long-term running, such as water meters.
1020 1020  
1021 -(((
1022 1022  The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
1023 1023  [[image:image-20220515075034-1.png||height="208" width="644"]]
1024 -)))
1025 1025  
1026 -(((
875 +
1027 1027  The minimum Working Voltage for the LHT65N is ~~ 2.5v. When battery is lower than 2.6v, it is time to change the battery.
1028 1028  
1029 -)))
1030 1030  
1031 -== 5.2 Replace Battery ==
879 +== Replace Battery ==
1032 1032  
1033 1033  LHT65N has two screws on the back, Unscrew them, and changing the battery inside is ok. The battery is a general CR17450 battery. Any brand should be ok.
1034 1034  
1035 1035  [[image:image-20220515075440-2.png||height="338" width="272"]][[image:image-20220515075625-3.png||height="193" width="257"]]
1036 1036  
1037 -== 5.3 Battery Life Analyze ==
1038 1038  
1039 -(((
886 +== Battery Life Analyze ==
887 +
1040 1040  Dragino battery-powered products are all run in Low Power mode. User can check the guideline from this link to calculate the estimated battery life:
1041 1041  https:~/~/www.dragino.com/downloads/downloads/LoRa_End_Node/Battery_Analyze/DRAGINO_Battery_Life_Guide.pdf
1042 -)))
1043 1043  
1044 -= 6. Order Info =
1045 1045  
1046 -(((
1047 -Part Number: (% style="color:#4f81bd" %)** LHT65N-XX-YY**
1048 -)))
892 += Order Info =
1049 1049  
1050 -(((
1051 -(% style="color:#4f81bd" %)**XX **(%%): The default frequency band
1052 -)))
894 +Part Number: (% class="mark" %)**LHT65N-XX**
1053 1053  
1054 -* (((
1055 -(% style="color:#4f81bd" %)** AS923**(%%): LoRaWAN AS923 band
1056 -)))
1057 -* (((
1058 -(% style="color:#4f81bd" %)** AU915**(%%): LoRaWAN AU915 band
1059 -)))
1060 -* (((
1061 -(% style="color:#4f81bd" %)** EU433**(%%): LoRaWAN EU433 band
1062 -)))
1063 -* (((
1064 -(% style="color:#4f81bd" %)** EU868**(%%): LoRaWAN EU868 band
1065 -)))
1066 -* (((
1067 -(% style="color:#4f81bd" %)** KR920**(%%): LoRaWAN KR920 band
1068 -)))
1069 -* (((
1070 -(% style="color:#4f81bd" %)** US915**(%%): LoRaWAN US915 band
1071 -)))
1072 -* (((
1073 -(% style="color:#4f81bd" %)** IN865**(%%): LoRaWAN IN865 band
1074 -)))
1075 -* (((
1076 -(% style="color:#4f81bd" %)** CN470**(%%): LoRaWAN CN470 band
1077 -)))
896 +**XX**: The default frequency band
1078 1078  
1079 -(((
1080 -(% style="color:#4f81bd" %)**YY**(%%): Sensor Accessories
1081 -)))
898 +* **AS923**: LoRaWAN AS923 band
899 +* **AU915**: LoRaWAN AU915 band
900 +* **EU433**: LoRaWAN EU433 band
901 +* **EU868**: LoRaWAN EU868 band
902 +* **KR920**: LoRaWAN KR920 band
903 +* **US915**: LoRaWAN US915 band
904 +* **IN865**: LoRaWAN IN865 band
905 +* **CN470**: LoRaWAN CN470 band
1082 1082  
1083 -* (((
1084 -(% style="color:#4f81bd" %)**E3**(%%): External Temperature Probe
1085 -)))
907 +**YY**: Sensor Accessories
1086 1086  
1087 -= 7. Packing Info =
909 +* **E3**: External Temperature Probe
1088 1088  
1089 -(((
911 += Packing Info =
912 +
1090 1090  **Package Includes**:
1091 -)))
1092 1092  
1093 -* (((
1094 -LHT65N Temperature & Humidity Sensor x 1
1095 -)))
1096 -* (((
1097 -Program cable x 1
1098 -)))
1099 -* (((
1100 -Optional external sensor
1101 -)))
915 +* LHT65N Temperature & Humidity Sensor x 1
916 +* Program cable x 1
917 +* Optional external sensor
1102 1102  
1103 -(((
1104 1104  **Dimension and weight**:
1105 -)))
1106 1106  
1107 -* (((
1108 -Device Size:  13.5 x 7 x 3 cm
1109 -)))
1110 -* (((
1111 -Device Weight: 105g
1112 -)))
1113 -* (((
1114 -Package Size / pcs : 14.5 x 8 x 5 cm
1115 -)))
1116 -* (((
1117 -Weight / pcs : 170g
1118 -)))
921 +* Device Size:  13.5 x 7 x 3 cm
922 +* Device Weight: 105g
923 +* Package Size / pcs : 14.5 x 8 x 5 cm
924 +* Weight / pcs : 170g
1119 1119  
1120 -= 8. FCC Warning =
926 += FCC Warning =
1121 1121  
1122 -(((
1123 1123  This device complies with part 15 of the FCC Rules.Operation is subject to the following two conditions:
1124 -)))
1125 1125  
1126 -(((
1127 -(1) This device may not cause harmful interference;
1128 -)))
930 +(1) This device may not cause harmful interference, and
1129 1129  
1130 -(((
1131 -(2) this device must accept any interference received, including interference that may cause undesired operation.
1132 -)))
932 +(2) this device must accept any interference received, including interference that may cause undesired operation
image-20220523115324-1.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -910.1 KB
Content
image-20220523144455-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -33.4 KB
Content
image-20220523150701-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -12.3 KB
Content
image-20220523150759-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -12.2 KB
Content
image-20220523150928-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -4.1 KB
Content
image-20220523151052-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -8.6 KB
Content
image-20220523151132-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -5.6 KB
Content
image-20220523151218-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -5.8 KB
Content
image-20220523151253-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.5 KB
Content
image-20220523151336-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.6 KB
Content
image-20220523151411-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -5.5 KB
Content
image-20220523151450-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -38.4 KB
Content
image-20220523151524-12.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -24.2 KB
Content
image-20220523151556-13.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -5.7 KB
Content
image-20220523152208-14.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.2 KB
Content
image-20220523152302-15.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -4.3 KB
Content
image-20220523152434-16.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -6.3 KB
Content
image-20220523152822-17.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -7.4 KB
Content
image-20220523152839-18.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -12.7 KB
Content
image-20220523153201-19.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -27.9 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0