<
From version < 91.1 >
edited by Edwin Chen
on 2022/05/25 00:47
To version < 97.1 >
edited by Xiaoling
on 2022/05/25 11:04
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -136,6 +136,12 @@
136 136  
137 137  [[image:image-20220523153201-19.png||height="180" width="818"]]
138 138  
139 +(% border="1" style="background-color:#ffffcc; color:green; width:878px" %)
140 +|=**Behavior on ACT**|=**Function**|=(% style="width: 561px;" %)**Action**
141 +|**Pressing ACT between 1s < time < 3s**|Test uplink status|(% style="width:561px" %)If LHT65N is already Joined to the LoRaWAN network, LHT65N will send an uplink packet, if LHT65N has an external sensor connected, blue led will blink once. If LHT65N has no external sensor, red led will blink once.
142 +|**Pressing ACT for more than 3s**|Active Device|(% style="width:561px" %)green led will fast blink 5 times, LHT65N will enter working mode and start to JOIN LoRaWAN network. green led will solid turn on for 5 seconds after join in network.
143 +|**Fast press ACT 5 times**|Deactivate Device|(% style="width:561px" %)red led will solid on for 5 seconds. This means LHT65N is in Deep Sleep Mode.
144 +
139 139  == 2.3 Example to join LoRaWAN network ==
140 140  
141 141  (% class="wikigeneratedid" %)
... ... @@ -205,10 +205,10 @@
205 205  |(% style="width:97px" %)(((
206 206  **Value**
207 207  )))|(% style="width:39px" %)(((
208 -[[BAT>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.2BAT-BatteryInfo]]
214 +[[BAT>>||anchor="H2.4.2BAT-BatteryInfo"]]
209 209  )))|(% style="width:100px" %)(((
210 210  (((
211 -[[Built-In Temperature>>http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.3Built-inTemperature]]
217 +[[Built-In Temperature>>||anchor="H2.4.3Built-inTemperature"]]
212 212  )))
213 213  )))|(% style="width:77px" %)(((
214 214  (((
... ... @@ -408,7 +408,7 @@
408 408  There are two methods:
409 409  
410 410  1. IoT Server sends a downlink LoRaWAN command to [[poll the value>>||anchor="H2.6.4Pollsensorvalue"]] for specify time range.
411 -1. Set [[PNACKMD=1>>||anchor="#H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will sent all messages after network recover.
417 +1. Set [[PNACKMD=1>>||anchor="H4.13AutoSendNone-ACKmessages"]], LHT65N will wait for ACK for every uplink, when there is no LoRaWAN network, LHT65N will store the sensor data, and it will send all messages after network recover.
412 412  
413 413  === 2.6.2 Unix TimeStamp ===
414 414  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0