<
From version < 80.1 >
edited by Edwin Chen
on 2022/05/24 23:53
To version < 77.1 >
edited by Xiaoling
on 2022/05/23 15:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:image-20220523115324-1.jpeg||height="317" width="317"]]
2 +[[image:image-20220523115324-1.jpeg||height="500" width="500"]]
3 3  
4 4  
5 5  **LHT65N LoRaWAN Temperature & Humidity Sensor Manual**
... ... @@ -6,7 +6,6 @@
6 6  
7 7  
8 8  
9 -
10 10  **Table of Contents:**
11 11  
12 12  {{toc/}}
... ... @@ -13,9 +13,8 @@
13 13  
14 14  
15 15  
15 += 1.Introduction =
16 16  
17 -= 1. Introduction =
18 -
19 19  == 1.1 What is LHT65N Temperature & Humidity Sensor ==
20 20  
21 21  (((
... ... @@ -134,7 +134,7 @@
134 134  
135 135  [[image:image-20220515123819-1.png||height="379" width="317"]]
136 136  
137 -[[image:image-20220523153201-19.png||height="180" width="818"]]
135 +[[image:image-20220523153201-19.png||height="163" width="739"]]
138 138  
139 139  == 2.3 Example to join LoRaWAN network ==
140 140  
... ... @@ -219,7 +219,7 @@
219 219  [[Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]]
220 220  )))
221 221  )))|(% style="width:47px" %)(((
222 -[[Ext>>path:http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.5Ext23]] #
220 +[[Ext>>path:#Extension_Sensor]] #
223 223  )))|(% style="width:51px" %)(((
224 224  [[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]]
225 225  )))
... ... @@ -401,18 +401,10 @@
401 401  
402 402  == 2.6 Datalog Feature ==
403 403  
404 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, LHT65N will store the reading for future retrieving purposes. There are two ways for IoT servers to get datalog from LHT65N.
402 +This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
405 405  
406 -=== 2.6.1 Ways to get datalog via LoRaWAN ===
404 +=== 2.6.1 Unix TimeStamp ===
407 407  
408 -There are two methods:
409 -
410 -1. IoT Server sends a downlink LoRaWAN command to [poll the value>PollSensorValue].
411 -1.
412 -
413 -
414 -=== 2.6.2 Unix TimeStamp ===
415 -
416 416  LHT65N uses Unix TimeStamp format based on
417 417  
418 418  [[image:image-20220523001219-11.png||height="97" width="627"]]
... ... @@ -430,7 +430,7 @@
430 430  
431 431  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
432 432  
433 -=== 2.6.3 Set Device Time ===
423 +=== 2.6.2 Set Device Time ===
434 434  
435 435  (((
436 436  There are two ways to set device’s time:
... ... @@ -464,7 +464,7 @@
464 464  User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
465 465  )))
466 466  
467 -=== [[2.6.4 Poll sensor value>>2.6.4 Poll sensor value||anchor="PollSensorValue"]] ===
457 +=== 2.6.3 Poll sensor value ===
468 468  
469 469  User can poll sensor value based on timestamps from the server. Below is the downlink command.
470 470  
... ... @@ -475,7 +475,7 @@
475 475  )))
476 476  
477 477  (((
478 -For example, downlink command (% style="display:none" %) (%%)**31 5FC5F350 5FC6 0160 05**
468 +For example, downlink command **31 5FC5F350 5FC6 0160 05**
479 479  )))
480 480  
481 481  (((
... ... @@ -487,7 +487,7 @@
487 487  )))
488 488  
489 489  
490 -=== 2.6.5 Datalog Uplink payload ===
480 +=== 2.6.4 Datalog Uplink payload ===
491 491  
492 492  The Datalog poll reply uplink will use below payload format.
493 493  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0