Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20220523115324-1.jpeg||height=" 317" width="317"]]2 +[[image:image-20220523115324-1.jpeg||height="500" width="500"]] 3 3 4 4 5 5 **LHT65N LoRaWAN Temperature & Humidity Sensor Manual** ... ... @@ -6,7 +6,6 @@ 6 6 7 7 8 8 9 - 10 10 **Table of Contents:** 11 11 12 12 {{toc/}} ... ... @@ -13,9 +13,8 @@ 13 13 14 14 15 15 15 += 1.Introduction = 16 16 17 -= 1. Introduction = 18 - 19 19 == 1.1 What is LHT65N Temperature & Humidity Sensor == 20 20 21 21 ((( ... ... @@ -134,7 +134,7 @@ 134 134 135 135 [[image:image-20220515123819-1.png||height="379" width="317"]] 136 136 137 -[[image:image-20220523153201-19.png||height="1 80" width="818"]]135 +[[image:image-20220523153201-19.png||height="163" width="739"]] 138 138 139 139 == 2.3 Example to join LoRaWAN network == 140 140 ... ... @@ -219,7 +219,7 @@ 219 219 [[Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]] 220 220 ))) 221 221 )))|(% style="width:47px" %)((( 222 -[[Ext>>path: http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.5Ext23]] #220 +[[Ext>>path:#Extension_Sensor]] # 223 223 )))|(% style="width:51px" %)((( 224 224 [[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]] 225 225 ))) ... ... @@ -300,7 +300,7 @@ 300 300 301 301 Timestamp mode is designed for LHT65N with E3 probe, it will send the uplink payload with Unix timestamp. With the limitation of 11 bytes (max distance of AU915/US915/AS923 band), the time stamp mode will be lack of BAT voltage field, instead, it shows the battery status. The payload is as below: 302 302 303 -(% border="1" style="background-color:#ffffcc; color:green; width: 510px" %)301 +(% border="1" style="background-color:#ffffcc; color:green; width:468px" %) 304 304 |(% style="width:96px" %)((( 305 305 **Size(bytes)** 306 306 )))|(% style="width:71px" %)((( ... ... @@ -401,18 +401,10 @@ 401 401 402 402 == 2.6 Datalog Feature == 403 403 404 - DatalogFeature istoensureIoTServer cangetallsamplingdatafromSensor even iftheLoRaWANnetworkis down.For eachsampling,LHT65Nwill store thereading for futureretrievingpurposes. Therearetwo ways forIoT serversto getdatalog from LHT65N.402 +This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot. 405 405 406 -=== 2.6.1 Waysto getdatalogvia LoRaWAN===404 +=== 2.6.1 Unix TimeStamp === 407 407 408 -There are two methods: 409 - 410 -1. IoT Server sends a downlink LoRaWAN command to [poll the value>PollSensorValue]. 411 -1. 412 - 413 - 414 -=== 2.6.2 Unix TimeStamp === 415 - 416 416 LHT65N uses Unix TimeStamp format based on 417 417 418 418 [[image:image-20220523001219-11.png||height="97" width="627"]] ... ... @@ -430,7 +430,7 @@ 430 430 431 431 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 432 432 433 -=== 2.6. 3Set Device Time ===423 +=== 2.6.2 Set Device Time === 434 434 435 435 ((( 436 436 There are two ways to set device’s time: ... ... @@ -464,7 +464,7 @@ 464 464 User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server. 465 465 ))) 466 466 467 -=== [[2.6.4Poll sensor value>>2.6.4Poll sensor value||anchor="PollSensorValue"]]===457 +=== 2.6.3 Poll sensor value === 468 468 469 469 User can poll sensor value based on timestamps from the server. Below is the downlink command. 470 470 ... ... @@ -475,7 +475,7 @@ 475 475 ))) 476 476 477 477 ((( 478 -For example, downlink command (% style="display:none" %) (%%)**31 5FC5F350 5FC6 0160 05**468 +For example, downlink command **31 5FC5F350 5FC6 0160 05** 479 479 ))) 480 480 481 481 ((( ... ... @@ -487,7 +487,7 @@ 487 487 ))) 488 488 489 489 490 -=== 2.6. 5Datalog Uplink payload ===480 +=== 2.6.4 Datalog Uplink payload === 491 491 492 492 The Datalog poll reply uplink will use below payload format. 493 493 ... ... @@ -495,7 +495,7 @@ 495 495 **Retrieval data payload** 496 496 ))) 497 497 498 -(% border="1" style="background-color:#ffffcc; color:green; width: 510px" %)488 +(% border="1" style="background-color:#ffffcc; color:green; width:469px" %) 499 499 |(% style="width:93px" %)((( 500 500 ((( 501 501 **Size(bytes)**