Content
... ... @@ -1,5 +1,5 @@
1 1  (% style="text-align:center" %)
2 -[[image:image-20220523115324-1.jpeg||height="317" width="317"]]
2 +[[image:image-20220523115324-1.jpeg||height="500" width="500"]]
3 3  
4 4  
5 5  **LHT65N LoRaWAN Temperature & Humidity Sensor Manual**
... ... @@ -14,7 +14,7 @@
14 14  
15 15  
16 16  
17 -= 1. Introduction =
17 += 1.Introduction =
18 18  
19 19  == 1.1 What is LHT65N Temperature & Humidity Sensor ==
20 20  
... ... @@ -401,14 +401,10 @@
401 401  
402 402  == 2.6 Datalog Feature ==
403 403  
404 -Datalog Feature is to ensure IoT Server can get all sampling data from Sensor even if the LoRaWAN network is down. For each sampling, LHT65N will store the reading for future retrieving purposes. There are two ways for IoT servers to get datalog from LHT65N.
404 +This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
405 405  
406 -=== 2.6.1 Ways to get datalog via LoRaWAN ===
406 +=== 2.6.1 Unix TimeStamp ===
407 407  
408 -When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot.
409 -
410 -=== 2.6.2 Unix TimeStamp ===
411 -
412 412  LHT65N uses Unix TimeStamp format based on
413 413  
414 414  [[image:image-20220523001219-11.png||height="97" width="627"]]
... ... @@ -426,7 +426,7 @@
426 426  
427 427  So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25
428 428  
429 -=== 2.6.3 Set Device Time ===
425 +=== 2.6.2 Set Device Time ===
430 430  
431 431  (((
432 432  There are two ways to set device’s time:
... ... @@ -460,7 +460,7 @@
460 460  User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
461 461  )))
462 462  
463 -=== 2.6.4 Poll sensor value ===
459 +=== 2.6.3 Poll sensor value ===
464 464  
465 465  User can poll sensor value based on timestamps from the server. Below is the downlink command.
466 466  
... ... @@ -483,7 +483,7 @@
483 483  )))
484 484  
485 485  
486 -=== 2.6.5 Datalog Uplink payload ===
482 +=== 2.6.4 Datalog Uplink payload ===
487 487  
488 488  The Datalog poll reply uplink will use below payload format.
489 489  