Changes for page LHT52 - LoRaWAN Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/30 14:27
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20220523115324-1.jpeg||height=" 317" width="317"]]2 +[[image:image-20220523115324-1.jpeg||height="500" width="500"]] 3 3 4 4 5 5 **LHT65N LoRaWAN Temperature & Humidity Sensor Manual** ... ... @@ -7,6 +7,10 @@ 7 7 8 8 9 9 10 + 11 + 12 + 13 + 10 10 **Table of Contents:** 11 11 12 12 {{toc/}} ... ... @@ -14,8 +14,9 @@ 14 14 15 15 16 16 17 -= 1. Introduction = 18 18 22 += 1.Introduction = 23 + 19 19 == 1.1 What is LHT65N Temperature & Humidity Sensor == 20 20 21 21 ((( ... ... @@ -134,7 +134,7 @@ 134 134 135 135 [[image:image-20220515123819-1.png||height="379" width="317"]] 136 136 137 -[[image:image-20220523153201-19.png||height="1 80" width="818"]]142 +[[image:image-20220523153201-19.png||height="163" width="739"]] 138 138 139 139 == 2.3 Example to join LoRaWAN network == 140 140 ... ... @@ -219,7 +219,7 @@ 219 219 [[Humidity>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.4Built-inHumidity]] 220 220 ))) 221 221 )))|(% style="width:47px" %)((( 222 -[[Ext>>path: http://8.211.40.43:8080/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.5Ext23]] #227 +[[Ext>>path:#Extension_Sensor]] # 223 223 )))|(% style="width:51px" %)((( 224 224 [[Ext value>>path:http://8.211.40.43/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LHT65N%20LoRaWAN%20Temperature%20%26%20Humidity%20Sensor%20Manual/#H2.4.6Extvalue]] 225 225 ))) ... ... @@ -401,14 +401,10 @@ 401 401 402 402 == 2.6 Datalog Feature == 403 403 404 - DatalogFeature istoensureIoTServer cangetallsamplingdatafromSensor even iftheLoRaWANnetworkis down.For eachsampling,LHT65Nwill store thereading for futureretrievingpurposes. Therearetwo ways forIoT serversto getdatalog from LHT65N.409 +This feature is always enabled. When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot. 405 405 406 -=== 2.6.1 Waysto getdatalogvia LoRaWAN===411 +=== 2.6.1 Unix TimeStamp === 407 407 408 -When user wants to retrieve the sensor value, he can send a poll command from the IoT platform to ask LHT65N to send the value in the required time slot. 409 - 410 -=== 2.6.2 Unix TimeStamp === 411 - 412 412 LHT65N uses Unix TimeStamp format based on 413 413 414 414 [[image:image-20220523001219-11.png||height="97" width="627"]] ... ... @@ -426,7 +426,7 @@ 426 426 427 427 So, we can use AT+TIMESTAMP=1611889405 or downlink 3060137afd00 to set the current time 2021 – Jan ~-~- 29 Friday 03:03:25 428 428 429 -=== 2.6. 3Set Device Time ===430 +=== 2.6.2 Set Device Time === 430 430 431 431 ((( 432 432 There are two ways to set device’s time: ... ... @@ -460,7 +460,7 @@ 460 460 User needs to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server. 461 461 ))) 462 462 463 -=== 2.6. 4Poll sensor value ===464 +=== 2.6.3 Poll sensor value === 464 464 465 465 User can poll sensor value based on timestamps from the server. Below is the downlink command. 466 466 ... ... @@ -471,7 +471,7 @@ 471 471 ))) 472 472 473 473 ((( 474 -For example, downlink command (% style="display:none" %) (%%)**31 5FC5F350 5FC6 0160 05**475 +For example, downlink command **31 5FC5F350 5FC6 0160 05** 475 475 ))) 476 476 477 477 ((( ... ... @@ -483,7 +483,7 @@ 483 483 ))) 484 484 485 485 486 -=== 2.6. 5Datalog Uplink payload ===487 +=== 2.6.4 Datalog Uplink payload === 487 487 488 488 The Datalog poll reply uplink will use below payload format. 489 489